Add a chapter for multipath on iSCSI and Fibre Channel SANs, written
around the tasks an admin has: prerequisites, setting up shared LVM
with the guided setup or by hand, adding, growing and removing a LUN,
reading the states during a path failure, array-specific settings and
moving over from a hand-made multipath.conf.
Removing a LUN stays a manual procedure, as Proxmox VE never removes a
WWID or a map by itself, so the chapter spells it out including how to
get out of queued I/O.
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
---
pmxcfs.adoc | 2 +
pve-storage-iscsi.adoc | 11 ++
pve-storage-iscsidirect.adoc | 2 +-
pve-storage-lvm.adoc | 3 +
pve-storage-multipath.adoc | 321 +++++++++++++++++++++++++++++++++++
pvesm.adoc | 18 +-
6 files changed, 351 insertions(+), 6 deletions(-)
create mode 100644 pve-storage-multipath.adoc
diff --git a/pmxcfs.adoc b/pmxcfs.adoc
index 1128425..2ab3fb3 100644
--- a/pmxcfs.adoc
+++ b/pmxcfs.adoc
@@ -105,6 +105,8 @@ Files
|`ha/manager_status` | JSON-formatted information regarding HA services on the cluster
|`ha/resources.cfg` | Resources managed by high availability, and their current state
|`ha/rules.cfg` | Rules putting constraints on the HA manager's scheduling of HA resources
+|`multipath-overrides.conf` | Hardware-specific multipath settings, in `multipath.conf` format, applied on all nodes
+|`multipath.cfg` | {pve} cluster-wide multipath configuration (LUN entries)
|`nodes/<NAME>/config` | Node-specific configuration
|`nodes/<NAME>/lxc/<VMID>.conf` | VM configuration data for LXC containers
|`nodes/<NAME>/openvz/` | Prior to {pve} 4.0, used for container configuration data (deprecated, removed soon)
diff --git a/pve-storage-iscsi.adoc b/pve-storage-iscsi.adoc
index a02ed46..2dcc196 100644
--- a/pve-storage-iscsi.adoc
+++ b/pve-storage-iscsi.adoc
@@ -23,6 +23,10 @@ resources.
Low-level iscsi management task can be done using the `iscsiadm` tool.
+TIP: To set up shared LVM on a LUN of an iSCSI target, use the guided setup
+under *Datacenter -> Storage -> SAN* in the web UI, see
+xref:storage_multipath_setup[Multipath].
+
Configuration
~~~~~~~~~~~~~
@@ -38,6 +42,13 @@ target::
iSCSI target.
+managed-multipath::
+
+Combine the paths to each LUN of the target into one `dm-multipath` map on every
+node the storage is enabled on, and monitor the maps cluster-wide. A shared LVM
+storage on a target with several portals needs multipath, through this option
+or set up by hand. See xref:storage_multipath[Multipath].
+
.Configuration Example (`/etc/pve/storage.cfg`)
----
diff --git a/pve-storage-iscsidirect.adoc b/pve-storage-iscsidirect.adoc
index ae722e8..97b0979 100644
--- a/pve-storage-iscsidirect.adoc
+++ b/pve-storage-iscsidirect.adoc
@@ -21,7 +21,7 @@ Configuration
~~~~~~~~~~~~~
The user mode iSCSI backend uses the same configuration options as the
-Open-iSCSI backend.
+Open-iSCSI backend, except for `managed-multipath`.
.Configuration Example (`/etc/pve/storage.cfg`)
----
diff --git a/pve-storage-lvm.adoc b/pve-storage-lvm.adoc
index d85c6f4..d09206b 100644
--- a/pve-storage-lvm.adoc
+++ b/pve-storage-lvm.adoc
@@ -143,6 +143,9 @@ A benefit of LVM is that it can be used with shared storage.
For example, an iSCSI LUN. The backend implements proper cluster-wide locking if
the storage is marked as shared in the configuration.
+TIP: The guided setup under *Datacenter -> Storage -> SAN* in the web UI creates
+a shared LVM storage on a SAN LUN, see xref:storage_multipath_setup[Multipath].
+
NOTE: If you extend a shared volume group onto another device on one node, the
other nodes may only see the added physical volume after LVM has scanned their
devices again, for example with `pvscan --cache`. This command also resets the
diff --git a/pve-storage-multipath.adoc b/pve-storage-multipath.adoc
new file mode 100644
index 0000000..e56bd92
--- /dev/null
+++ b/pve-storage-multipath.adoc
@@ -0,0 +1,321 @@
+[[storage_multipath]]
+Multipath
+---------
+ifdef::wiki[]
+:pve-toplevel:
+:title: Storage: Multipath
+endif::wiki[]
+
+Use multipath for shared LVM on an iSCSI or Fibre Channel SAN with redundant
+connections. Device-mapper multipath combines the paths to a LUN into one block
+device, called a map, so I/O can continue when a path fails. Its World Wide
+Identifier (WWID) identifies the same LUN on every node.
+
+{pve} configures maps cluster-wide and shows their state under *Datacenter ->
+Storage -> SAN*. An iSCSI storage with *Multipath* enabled requests maps for its
+LUNs; Fibre Channel LUNs need entries in `/etc/pve/multipath.cfg`. NVMe
+namespaces use kernel-native multipath instead; the procedures below cover SCSI
+LUNs.
+
+Prerequisites
+~~~~~~~~~~~~~
+
+. Upgrade all nodes before enabling cluster-wide multipath management. A node
+ with an older version does not apply the multipath configuration, and it
+ removes the *Multipath* option of iSCSI storages from the cluster-wide storage
+ configuration when it writes that configuration, for example when a storage is
+ added or edited on that node.
+. Install `multipath-tools` on every participating node. The
+ `libpve-storage-perl` package recommends it, but installations without
+ recommended packages need it added separately. A node without it shows
+ *Multipath unavailable* with the reason under *Datacenter -> Storage -> SAN*.
+ Plain iSCSI and LVM without the multipath option still work without it.
+. Allow each node's iSCSI initiator name on the array; the names are shown under
+ *Datacenter -> Storage -> SAN* and in the guided setup. Install `open-iscsi`
+ if needed.
+ For Fibre Channel, configure zoning and LUN masking for the WWPNs of each
+ node's HBA ports, which `cat /sys/class/fc_host/host*/port_name` lists.
+. Present the same empty LUN to all intended nodes over redundant paths. A node
+ does not scan for a Fibre Channel LUN that is mapped to it later, so rescan
+ the Fibre Channel hosts on each node:
++
+----
+# for host in /sys/class/fc_host/host*; do echo '- - -' > /sys/class/scsi_host/${host##*/}/scan; done
+----
++
+If the LUN still does not show up, check the target ports of the array on the
+node. This lists the WWPN, state and roles of each remote port; those of the
+array need the state `Online` and the role `FCP Target`. A `Blocked` port needs
+its connection restored before a rescan can reach it:
++
+----
+# for port in /sys/class/fc_remote_ports/rport-*; do echo $(cat $port/{port_name,port_state,roles}); done
+----
+
+[[storage_multipath_setup]]
+Setting Up Shared LVM
+~~~~~~~~~~~~~~~~~~~~
+
+. Open *Datacenter -> Storage -> SAN* in the web UI on a node that can access
+ the LUN and select *Guided Setup -> LVM on iSCSI* or *LVM on Fibre Channel*.
+. For iSCSI, enter a portal, select the target and name the connection storage.
+ This storage connects to the target with `content none` and *Multipath*
+ enabled, while the LVM storage manages guest disks. Leave *Nodes* under
+ *Advanced* empty to use all nodes. With a reused connection storage, empty
+ means all nodes of that storage. Continuing creates or reuses the connection
+ storage before you select a LUN.
+. Select the LUN, choose the storage ID and volume group, then confirm. For
+ Fibre Channel, leave *Nodes* under *Advanced* empty to use all nodes. Virtual
+ machines on the storage can only have snapshots with
+ *Allow Snapshots as Volume-Chain*, which applies to disks created after it is
+ set; see xref:pvesm_lvm_config[LVM configuration].
+. Check the state of the LUN on each node of the storage, which the setup
+ shows once the storage is added. Before that, only the node serving the web
+ UI looked at the LUN; the LUN list names it as *Scan node*. The other nodes
+ set the LUN up with their next status updates and show *Pending* during the
+ first minute. For a node that stays *Missing*, check its access to the LUN
+ on the array before placing guests on the storage. *OK (1 path)* means that
+ the node reaches the LUN over a single path. The *State* column of the view
+ shows the same later.
+
+For Fibre Channel, the setup adds the multipath entry of the LUN if it has none.
+It then waits for the map on the node serving the web UI and sets *Expected
+Paths* of that entry to the number of paths of the map, if that is at least
+two. Existing entries and maps stay as they are; a map that was set up by hand
+gets no entry, so check that the other nodes have it as well. Set *Expected
+Paths* in the entry if it is missing or does not match the intended topology,
+for example because a fabric was down at that time or nodes have different
+path counts.
+
+If setup fails, check the error, the node's task log and *Datacenter ->
+Storage* before retrying; closing the dialog does not undo changes.
+
+A LUN that a storage uses cannot be selected, and the setup refuses a LUN with
+data it recognizes, such as a partition table, a file system or a volume group.
+To keep a volume group that a LUN already holds, do not wipe the LUN: add the
+volume group under *Datacenter -> Storage -> Add -> LVM* with *Shared* enabled.
+
+To reuse a LUN whose data is no longer needed, first stop all its users on all
+hosts and remove its storage references, then use *Wipe* under *Node -> SAN* as
+`root@pam`. This destroys its data. Before the setup or the wipe writes to a
+LUN, the node checks for processes that have it open, also through another of
+its paths, for example a guest that uses it as a disk. This does not find every
+user: not one that opened the LUN through another device node, and none on
+other hosts. A partition of a LUN or of its map, selected on its own, only gets
+the checks of a local disk. The usage shown for a LUN is cached per node, so
+other nodes can still show the old content after a wipe.
+
+The dialogs under *Datacenter -> Storage -> Add* can do the same for iSCSI in
+two steps: add an *iSCSI* storage with *Multipath* enabled and *Use LUNs
+directly* cleared, then an *LVM* storage with it as *Base storage* and the LUN
+as *Base volume*. Selecting a base storage enables *Shared*; keep it enabled.
+
+To set up iSCSI by hand, run these commands on a node with access to the target:
+
+----
+# pvesm add iscsi <connection> --portal <portal> --target <iqn> \
+ --content none --managed-multipath 1
+# pvesm list <connection> --content images
+# pvesm add lvm <storage> --vgname <vg> --base <volume-id> --shared 1
+----
+
+Use the complete volume ID from the listing, including the connection storage
+prefix and the `dm-uuid-mpath-<wwid>` suffix. Adding the LVM storage creates the
+volume group. Keep its base volume: it connects the target before LVM
+activation.
+
+For Fibre Channel, add an entry with the number of paths each node should
+have, wait for the scan to show a by-id path with `dm-uuid-mpath-<wwid>`, then
+create the volume group and shared storage:
+
+----
+# pvesh create /cluster/multipath/wwid --wwid <wwid> --paths-expected <paths>
+# pvesm scan san-luns --output-format json
+# pvesh create /nodes/<node>/disks/lvm --name <storage> \
+ --device /dev/disk/by-id/dm-uuid-mpath-<wwid> --add_storage 1
+----
+
+These examples allow all nodes. For a subset, set `--nodes <nodes>`, a
+comma-separated list, on the entry or iSCSI storage and on the LVM storage. For
+Fibre Channel, leave out `--add_storage 1` and then add the storage with `pvesm
+add lvm <storage> --vgname <storage> --shared 1 --nodes <nodes>`. `pvesh` waits
+for the creation task; check its output for errors before using the storage.
+
+Adding Another LUN
+~~~~~~~~~~~~~~~~~~
+
+. Present the new LUN to the same nodes on the array. Enabled iSCSI storages
+ rescan their sessions automatically; for Fibre Channel, rescan the hosts as
+ shown in the prerequisites.
+. Run the guided setup again. For iSCSI, select the same target to reuse its
+ connection storage. If it lacks *Multipath*, enable that option in its edit
+ dialog first, observing the migration advice below.
+. Select the new LUN and create a separate LVM storage. By hand, repeat the
+ iSCSI listing and LVM command above, or the Fibre Channel procedure.
+
+[[storage_multipath_grow]]
+Growing a LUN
+~~~~~~~~~~~~~
+
+. Grow the LUN on the array. Never shrink a LUN in use.
+. Wait for the iSCSI session rescan, or rescan each SCSI path on every Fibre
+ Channel node with `echo 1 > /sys/block/<path>/device/rescan`, where `<path>`
+ is a member device such as `sdc`, not the map.
+. Check the map size on every node with `multipath -ll <wwid>` or under
+ *Node -> SAN*. The generated configuration sets `auto_resize grow_only`:
+ the map grows once all its paths report the new size. If necessary, run
+ `multipathd resize map <map>` after all paths have grown.
+. Run `pvresize /dev/disk/by-id/dm-uuid-mpath-<wwid>` on one node only, after
+ every node's map has grown. A smaller map cannot access the added space.
+
+[[storage_multipath_remove]]
+Removing a LUN
+~~~~~~~~~~~~~~
+
+{pve} never flushes maps or removes WWIDs from `/etc/multipath/wwids`.
+Removing a configuration entry is not enough. A map that queues I/O without
+paths can block guests and LVM commands, so disable queueing before unmapping:
+
+. Stop all users of the LUN on all hosts, or move their data elsewhere. Remove
+ the LVM storage with `pvesm remove <storage>` and deactivate its volume group
+ on every node with `vgchange -an <vg>`. Neither command erases the data.
+. Set an existing entry to fail I/O with
+ `pvesh set /cluster/multipath/wwid/<wwid> --no-path-retry fail`.
+ If none exists, create one with
+ `pvesh create /cluster/multipath/wwid --wwid <wwid> --no-path-retry fail`.
+ Add `--nodes <nodes>` if only a subset of nodes sees the LUN.
+. Wait until `multipath -ll <wwid>` on every participating node no longer lists
+ `queue_if_no_path` in the map's features. Wait for offline nodes to return.
+ Record the map name and member devices, and each member's identifier from
+ `/sys/block/<path>/device/wwid`.
+. Unmap the LUN on the array.
+. On every node, flush the map with `multipath -f <map>`. If it is busy, retry
+ after a few seconds; if it stays busy, find and stop its remaining users. Do
+ not force removal. For each recorded path,
+ check that its identifier is unchanged, then delete it with
+ `echo 1 > /sys/block/<path>/device/delete`. Skip paths already gone; stop if
+ an identifier changed.
+. Remove the explicit entry with `pvesh delete /cluster/multipath/wwid/<wwid>`.
+ Removing it earlier makes the nodes apply the default retry policy of the
+ array again, which can queue I/O on a map that is not flushed yet and block
+ whatever opens it.
+. On every node, wait until its next status update has removed the WWID from
+ `/etc/multipath/conf.d/pve-aliases.conf`, which takes about ten seconds, then
+ run `multipath -w <wwid>` to remove it from the allow-list. Running it before
+ that update can let the update add the WWID again. Check that
+ `grep -c '^/<wwid>/$' /etc/multipath/wwids` prints 0, and again after the
+ next status update.
+
+If the LUN was already unmapped and I/O is stuck, run
+`multipathd disablequeueing map <map>` on each affected node, then continue
+with the removal procedure.
+
+[[storage_multipath_disconnect]]
+Removing an iSCSI connection storage does not log out its sessions. Keep it
+while other LUNs of the target are in use; session maintenance is done with
+`iscsiadm`, not the read-only *Node -> SAN -> iSCSI* view.
+
+Checking Path Failures
+~~~~~~~~~~~~~~~~~~~~~
+
+*Datacenter -> Storage -> SAN* shows node availability, configuration errors
+and LUN states. It lists the LUNs that {pve} manages or uses: those with an
+explicit entry, those of an iSCSI storage with *Multipath* enabled, and those
+that are the base volume of a storage or hold its volume group. Other maps of a
+node, for example the ones of a third-party storage plugin, are only counted
+under *Other Maps*; *Node -> SAN* lists them as well. The volume groups come
+from the hint file of LVM. While LVM has none, for example because it sees
+duplicate PVs, a node cannot tell which of its other maps hold the volume group
+of a storage and leaves them all out. A LUN that is only listed for its volume
+group then shows *Unknown* for that node, or is not listed if no node reports
+it.
+
+The *State* of a LUN is the worst known state among its nodes. For a state other
+than *Optimal*, it names the nodes in that state, unless all nodes are in it.
+Nodes in *Unknown* do not count for it and are listed after it. Hover over it
+for the states and path counts of all nodes. *Multipath* describes how the map
+is managed, not its health: by an explicit entry, by the storage that requests
+it, or *Unmanaged* for a map that {pve} did not set up. Under *Node -> SAN*, a
+degraded or failed LUN shows its usable and expected paths; expand it to inspect
+individual paths. An iSCSI or Fibre Channel LUN without a map has its devices
+as paths, in the state that the kernel reports for each, and nothing fails over
+between them. With a single device and no map requested for it, *Multipath*
+shows *Single path*. *Node -> SAN -> iSCSI* shows targets and sessions.
+
+*Optimal*:: All known paths are usable and no expected path is missing.
+*OK (1 path)*:: The only path is usable, and there is no other path to fail
+over to. The API reports this as `optimal` with one path.
+*Degraded*:: Some paths are unusable or fewer paths exist than expected.
+*Failed*:: No usable path remains; I/O queues or fails according to the retry
+policy.
+*Missing*:: A node with a current report is expected to have the LUN but does
+not.
+*Unknown*:: No usable current observation is available for that node.
+
+During a path failure, inspect the degraded LUN's paths and restore the failed
+connection. The state returns to *Optimal* when the paths recover. Check node
+availability too: unknown observations do not worsen a known LUN state.
+
+The status report of a node is limited to 32 KiB, which is enough for about 180
+listed LUNs with typical names. A node with more reports `too many LUNs to
+report` and no LUNs: those that the configuration expects on it show *Unknown*
+for that node, and LUNs that only this node reports are missing from the list.
+
+An iSCSI storage expects one path per portal. A portal that a node cannot reach
+keeps the LUNs of that storage *Degraded* on that node, so the array should
+report to each node only the portals that it can reach. For a Fibre Channel LUN,
+set *Expected Paths* in its multipath entry, as the guided setup does. Without
+it, a node only shows as *Degraded* while its lost paths are still listed.
+Depending on the settings for the array, the kernel removes a path that stays
+down longer than `dev_loss_tmo`, and the map then shows *Optimal* with fewer
+paths, or *OK (1 path)* for the last one. NVMe namespaces have no multipath
+entries and so no expected path count: once the kernel removes a lost path,
+after a timeout that depends on how the path was connected, the namespace shows
+its remaining paths in the same way.
+
+[[storage_multipath_config]]
+Array Settings and Existing Configurations
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Use the built-in device profiles unless the array vendor requires changes.
+*Edit Overrides* under *Datacenter -> Storage -> SAN* edits
+`/etc/pve/multipath-overrides.conf` for all nodes. For example, to set a retry
+count for one array model (replace the vendor and product expressions):
+
+----
+devices {
+ device {
+ vendor "<vendor>"
+ product "<product>"
+ no_path_retry 12
+ }
+}
+----
+
+The generated configuration sets `auto_resize grow_only` for the growing of
+LUNs. `multipath` only has this setting for all maps of a node, so it also
+applies to maps that {pve} does not manage, for example the ones of a
+third-party storage plugin: they grow once all their paths have grown. To keep
+the resize manual on all nodes, add this to the overrides:
+
+----
+defaults {
+ auto_resize never
+}
+----
+
+To move from a hand-made `/etc/multipath.conf`:
+
+. Back up the local configuration on every node. Move shared array settings to
+ the overrides file; add WWID entries under *Datacenter -> Storage -> SAN* for
+ Fibre Channel LUNs or per-LUN aliases and `no-path-retry` settings.
+. Enable *Multipath* on existing iSCSI storages. Keep existing LVM base volumes.
+ Check `multipathd show config` on every node before removing duplicate local
+ settings. Do not edit the generated `/etc/multipath/conf.d/pve-*.conf` files.
+. Wait until *Datacenter -> Storage -> SAN* shows the LUNs of these storages on
+ every node. Then check active volume dependencies with `lsblk` on each node.
+ Enabling multipath does not move active volumes off individual paths. Stop and
+ restart affected guests, or migrate them away and back, before relying on path
+ redundancy. Keep `multipath_component_detection` enabled in
+ `/etc/lvm/lvm.conf`, as it is by default, and follow the
+ xref:storage_lvm[shared LVM autoactivation guidance].
diff --git a/pvesm.adoc b/pvesm.adoc
index 07a7917..f7de231 100644
--- a/pvesm.adoc
+++ b/pvesm.adoc
@@ -96,11 +96,10 @@ TiB sized), these operations may take several minutes, or in extreme cases, even
hours. If your setup is affected, create and remove snapshots while the VM is
shut down, expecting a long task duration.
-^3^: With iSCSI, FibreChannel (FC), or SAS block storage as shared storage in a
-cluster, LVM is used to split the LUN into virtual disks. The
-https://pve.proxmox.com/wiki/Multipath[Multipath Guide] explains how to
-configure it in a cluster, including multipathing which is usually a
-requirement in these scenarios.
+^3^: With iSCSI, Fibre Channel (FC), or SAS block storage as shared storage in
+a cluster, LVM is used to split the LUN into virtual disks. A LUN is usually
+reachable over several paths; xref:storage_multipath[Multipath] describes how
+{pve} manages them in a cluster.
^4^: Since {pve} 9, snapshots as a volume chain have been available for VMs.
These snapshots use separate volumes for the snapshot data and layer them. For
@@ -153,6 +152,11 @@ also useful for local storage types. In this case such local storage
is available on all nodes, but it is physically different and can have
totally different content.
+Add storage under *Datacenter -> Storage -> Add* in the web UI. For shared LVM
+on a xref:storage_multipath_setup[SAN LUN], use *Guided Setup* under
+*Datacenter -> Storage -> SAN* instead. It creates the storages that are needed
+and enables multipath for the LUN.
+
Storage Pools
~~~~~~~~~~~~~
@@ -500,6 +504,8 @@ See Also
* link:/wiki/Storage:_iSCSI[Storage: iSCSI]
+* link:/wiki/Storage:_Multipath[Storage: Multipath]
+
* link:/wiki/Storage:_LVM[Storage: LVM]
* link:/wiki/Storage:_LVM_Thin[Storage: LVM Thin]
@@ -542,6 +548,8 @@ include::pve-storage-iscsi.adoc[]
include::pve-storage-iscsidirect.adoc[]
+include::pve-storage-multipath.adoc[]
+
include::pve-storage-rbd.adoc[]
include::pve-storage-cephfs.adoc[]
next prev parent reply other threads:[~2026-11-19 19:54 UTC|newest]
Thread overview: 44+ messages / expand[flat|nested] mbox.gz Atom feed top
2026-11-19 19:46 [PATCH v8 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 cluster 01/43] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 02/43] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 03/43] diskmanage: qualify NVMe over Fabrics transport Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 04/43] diskmanage: optionally include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 05/43] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 06/43] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 07/43] multipath: add a library around multipathd Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 08/43] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 09/43] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 10/43] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 11/43] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 12/43] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 13/43] multipath: publish per-node status Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 14/43] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 15/43] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 16/43] diskmanage: look up the requested disks by name Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 17/43] diskmanage: read the udev data of all disks with one call Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 18/43] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 19/43] pvesm: expose the " Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 20/43] api: add node-level iSCSI status Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 21/43] api: scan: name the portal of an iSCSI path Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 22/43] disks: lvm: drop unused imports Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 23/43] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 24/43] disks: lvm: refuse to destroy the volume group of a shared storage Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 25/43] disks: allow wiping a SAN LUN that no storage uses Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 storage 26/43] api: scan: report the process that has a SAN LUN open Thomas Lamprecht
2026-11-19 19:46 ` Thomas Lamprecht [this message]
2026-11-19 19:46 ` [PATCH v8 docs 28/43] storage: multipath: describe the use shown for an open LUN Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 29/43] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 30/43] report: add the managed multipath configuration Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 31/43] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 32/43] api: nodes: expose the iSCSI status Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 33/43] ui: dc: add a SAN view Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 34/43] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 35/43] ui: lvm: enable shared when a base storage is selected Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 36/43] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 37/43] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 38/43] ui: node: san: show iSCSI targets and sessions Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 39/43] ui: dc: san: add a guided setup for shared LVM on iSCSI Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 40/43] ui: dc: san: add a guided setup for shared LVM on Fibre Channel Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 41/43] ui: storage: point the iSCSI and LVM add dialogs to the SAN view Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 42/43] ui: san: show the guest or process that has a LUN open Thomas Lamprecht
2026-11-19 19:46 ` [PATCH v8 manager 43/43] ui: node: san: add a column for the target or subsystem of a LUN Thomas Lamprecht
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20261119194655.3163258-28-t.lamprecht@proxmox.com \
--to=t.lamprecht@proxmox.com \
--cc=pve-devel@lists.proxmox.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox