public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
* [PATCH v7 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM
@ 2026-11-18 20:25 Thomas Lamprecht
  2026-11-18 20:25 ` [PATCH v7 cluster 01/43] cfs: observe the multipath configuration files Thomas Lamprecht
                   ` (43 more replies)
  0 siblings, 44 replies; 45+ messages in thread
From: Thomas Lamprecht @ 2026-11-18 20:25 UTC (permalink / raw)
  To: pve-devel

This is v7 of the combined and reduced series of the cluster-wide
multipath work [0][1] and Dietmar's RFC for guided remote storage setup
and SAN visibility [2].

v7 is v6 [8] plus what some independent reviews and further lab testing
of v6 turned up, i.e.:

 - The checks before a wipe or volume group creation take the members
   of a map from the kernel too, not only those whose WWID multipathd
   or udev reports, so a guest on such a path or its target is found.
   The LUN list names a guest that writes to a partition of a LUN, which
   the wipe refused but the list showed as unused.
 - The web UI no longer falls back to a device name like /dev/sdX for a
   wipe or for the Fibre Channel volume group: a name that passed to
   another LUN in between would lead there. A LUN without a name under
   /dev/disk/by-id cannot be wiped from the list, which the node refused
   anyway, and the Fibre Channel setup waits for that name of the map.
 - A drop-in is only replaced if its first line is the generated one,
   v6 also took "# Not managed by Proxmox VE", and a node checks all
   drop-ins before it changes one. The overrides refuse text after a
   '{' and a '}' that is not alone on its line: multipath ignores the
   rest of such a line, and with it the sections after it.
 - A LUN that a storage requests, but that no node has assembled, shows
   as Missing in the SAN view instead of not at all. An LVM base named
   after the scsi- link of a LUN is attributed to its storage.
 - pvestatd applies the multipath configuration right before the
   storage status, so the node and guest status do not wait for it.
 - The iSCSI setup offers the LUNs that the connection storage lists,
   also one that the scan attributes to another target of the array,
   finds a LUN by name, WWID or path, and says which storage blocks the
   reuse of a target and why. The initiator names and the window at the
   end follow the nodes of the new storage. The Fibre Channel recovery
   texts name the volume group and storage ID.
 - Enable Multipath under Node > SAN is offered for Fibre Channel LUNs
   only, not for an NVMe namespace without native multipath.
 - The LUN list names a guest only to users who may see it.
 - Smaller ones: the status summary is described as the worst known
   state, Expected Paths as the highest of the entry and the portal
   counts, the Node > Disks > LVM dialog says that Add Storage on a SAN
   LUN creates a shared storage for all nodes, error messages name what
   to use instead, and the chapter says what a reader of a LUN and a
   kernel partition of it mean for the checks.

What I left as is: findings that repeat points decided for v5 [3],
except the first-target filter of the iSCSI setup, which the content
listing now makes cheap to fix, and master's behavior, such as a kernel
partition of a LUN that is selected on its own, which the chapter now
mentions. wipefs on the claimed device does not re-read the partition
table, but udev does once the wipe closes the device, as the lab showed.

Overview of what an admin gets with this:

 - Datacenter > Storage > SAN, a new entry below Storage, shows the
   multipath state of every node and of the LUNs that Proxmox VE
   manages or has a storage on, and edits the multipath entries and
   array-specific overrides. I explicitly chose this over the
   client/plugin side of Storage, as we do not have e.g. Ceph or
   ZFS/LVM/... creation in there either. We might want to rethink and
   consolidate our storage interface vs. management story in the
   future, but IMO a partial switch now is not worth it, that would add
   even more potential for confusion than the new SAN view.
 - Its Guided Setup menu leads through shared LVM on a LUN: for iSCSI it
   connects or reuses a target, with the initiator names of its nodes at
   hand, for Fibre Channel it takes a LUN the nodes already see. Both
   set up multipath and end with the state of the LUN on every node.
 - Datacenter > Storage > Add keeps its dialogs. The iSCSI one gets a
   Multipath option and the LVM one enables Shared for a base storage,
   and both point to the SAN view.
 - Node > SAN lists the LUNs of a node with their paths and usage, can
   wipe a LUN that no storage uses, and shows the iSCSI sessions.

The rules the series follows since v4: nodes add WWIDs and maps but
never remove them, a write is checked where it happens, lists do not
probe devices, there are no new iSCSI operations, the guided setup makes
the API calls an admin would make by hand, and multipath management is
turned on by the admin. The v4 cover [7] has the reasons.

Two things an admin will likely miss: there is no notification when a
LUN loses path redundancy, the state only shows on the SAN pages and in
the API. And Fibre Channel starts at a LUN the nodes already see; the
chapter gives the commands to list WWPNs and rescan the HBAs.

How it works:

 - /etc/pve/multipath.cfg holds explicit entries per WWID,
   /etc/pve/multipath-overrides.conf array settings; patch 01
   registers both. An iSCSI storage with the 'managed-multipath' option
   supplies its LUNs without entries. The option is not named
   'multipath', as third-party plugins use that name, and the storage
   layer leaves out a third-party plugin that declares a property of
   another plugin.
 - pvestatd calls one function of pve-storage per pass. It adds the
   WWIDs the node needs to /etc/multipath/wwids, writes the drop-ins
   /etc/multipath/conf.d/pve-*.conf, reloads multipathd after a change,
   and publishes the state of the maps that Proxmox VE manages or that a
   storage builds on through the node key-value store.
 - /cluster/multipath/status aggregates these reports;
   /cluster/multipath/{wwid,overrides} edit the two files;
   /nodes/{node}/scan/san-luns lists the LUNs of a node and
   /nodes/{node}/iscsi its sessions.
 - The volumes of an iSCSI storage with the option are named after the
   multipath map, so an LVM storage uses them through 'base' as before.
 - Volume group creation and wipe run under a cluster lock per LUN. They
   refuse a LUN that a storage uses or a process of the node has open,
   also through another path. Opens through another device node, such as
   one of a container, and users on other hosts are not seen.

Patches:

 - cluster 01: register the two configuration files
 - storage 02-26: helpers for the disk and iSCSI session inventory
   (mostly Dietmar's), the multipath library and configuration, the
   iSCSI option, the per-node apply and status with their API, the disk
   list of many disks, the LUN inventory, the read-only iSCSI status and
   the portal of an iSCSI path, volume groups on LUNs, the wipe and the
   process that has a LUN open
 - docs 27-28: the multipath chapter, rewritten around tasks, and the
   paragraph for a LUN that a process has open
 - manager 29-43: the pvestatd call, report and API mounts, then the
   views, the two dialog changes, the two guided setups, the note in the
   add dialogs, and the guest or process and the target of a LUN

Other changes since v6 [8]:

 - rebased onto current master; for pve-manager and pve-docs that has a
   commit each that ends the technology preview status of snapshots as
   volume chains, as they are ready for production use. The guided
   setup and the chapter no longer call them a technology preview
   either
 - the node list of Datacenter > Storage > SAN links each node to its
   Node > SAN view, like the content of a storage links a volume to its
   guest
 - Blockbridge tested v6 with their storage plugin, which runs its own
   sessions, thanks! From that: Node > SAN shows a LUN without a
   multipath map with its devices as paths, in the state that the kernel
   reports for each, so a LUN with a single path also shows whether it
   is up. Its Multipath column says Single path for one device, and an
   iSCSI path names the portal of its session. The target column also
   shows the subsystem of an NVMe namespace, and the LUN lists sort by
   the names and uses they show
 - the Wipe button under Node > SAN sits apart from the other buttons,
   and its dialog also asks to confirm that no other host uses the LUN,
   as the checks before the wipe only see such a use through a storage
 - the subject of patch 3 spells NVMe over Fabrics like the rest

When applying, versioned dependencies have to be set: pve-manager on
libpve-storage-perl, and libpve-storage-perl (also as build dependency)
on the libpve-cluster-perl with patch 01, as PVE::Storage
registers the two files when it is loaded. pve-cluster with the same
patch keeps the version counters of the two files; with an older pmxcfs
they are read and parsed again on every request. pve-manager also needs
the pve-doc-generator (build) and pve-docs with the multipath chapter,
for its help links. If the bound for LVM status commands [4] gets
applied too, whichever is applied second has to pass the status cache to
the two lvm_vgs() calls of the base volume activation, as they can block
a status pass otherwise. Both mark the cache of the status update with
'status_only', in the same line.

The per-node target and portal series [5][6] are independent of this
one. It takes the LUNs of an iSCSI storage from the sessions of its one
target, so if a storage can have several targets per node, whichever is
applied second has to cover that.

I tested v7 on the lab of v4 [7] to v6, upgraded from the v6 build,
with the NVMe over Fabrics series and [4] on top. The checks of the
fixes ran there: a drop-in with a near-match first line stayed and the
node reported the conflict without touching another file, overrides
on one line were refused, a guest with a partition of an NVMe/TCP
namespace as disk showed in the LUN list and kept the wipe from running,
a storage administrator without VM.Audit got the process but not the
guest, and the button states under Node > SAN were as described. The
iSCSI setup ran on the NetApp with a search, two of six nodes and the
reuse of the connection storage, the target conflict with two storages,
and the Fibre Channel setup with a new entry, once to the end and once
with the task status lost. The link of a node in the SAN view and the
storage dialogs and setup without the technology preview hint I checked
on the final build. A node logged in to an iSCSI target without a map,
as a plugin with its own sessions does, showed OK (1 path) and Single
path, then Failed with the path blocked when its portal was cut, and
with a second portal Optimal and Degraded; the LUN list took 0.6 s
during the cut. The partition lookup of the LUN list costs about 34 us
per device, so 0.1 s for 1000 LUNs with two paths. I looked at each
changed view and dialog. For the rest, the tests of v6 [8] still apply;
I did not repeat the guest, path cut of maps and scale tests.

[0]: https://lore.proxmox.com/pve-devel/20260626121000.2095591-1-t.lamprecht@proxmox.com/
[1]: https://lore.proxmox.com/pve-devel/20260703124707.1172980-2-t.lamprecht@proxmox.com/
[2]: https://lore.proxmox.com/pve-devel/20260731102156.3947857-1-dietmar@proxmox.com/
[3]: https://lore.proxmox.com/pve-devel/20261116012355.3187417-1-t.lamprecht@proxmox.com/
[4]: https://lore.proxmox.com/pve-devel/20261111015217.941220-1-t.lamprecht@proxmox.com/
[5]: https://lore.proxmox.com/pve-devel/20260430173220.441001-1-m.limbeck@proxmox.com/
[6]: https://lore.proxmox.com/pve-devel/20260804090819.2136483-1-dietmar@proxmox.com/
[7]: https://lore.proxmox.com/pve-devel/20261113030146.1559030-1-t.lamprecht@proxmox.com/
[8]: https://lore.proxmox.com/pve-devel/20261118065302.3033937-1-t.lamprecht@proxmox.com/

pve-cluster:

Thomas Lamprecht (1):
      cfs: observe the multipath configuration files

 src/PVE/Cluster.pm  | 2 ++
 src/pmxcfs/status.c | 2 ++
 2 files changed, 4 insertions(+)

pve-storage:

Dietmar Maurer (8):
      diskmanage: collect disk transport type from lsblk
      diskmanage: qualify NVMe over Fabrics transport
      diskmanage: optionally include iSCSI session devices in disk enumeration
      diskmanage: collect native NVMe multipath path state
      iscsi: factor out session device map from device list
      diskmanage: add helper to list multipath devices
      pvesm: expose the SAN LUN inventory
      api: add node-level iSCSI status

Thomas Lamprecht (17):
      multipath: add a library around multipathd
      multipath: add a cluster-wide configuration
      iscsi: add an option to manage storage LUNs with multipath
      lvm: activate a missing base volume before using the volume group
      multipath: apply the configuration on every node
      multipath: publish per-node status
      api: add endpoints for the cluster-wide multipath configuration
      api: multipath: add the cluster-wide health status
      diskmanage: look up the requested disks by name
      diskmanage: read the udev data of all disks with one call
      api: scan: add a SAN LUN inventory
      api: scan: name the portal of an iSCSI path
      disks: lvm: drop unused imports
      disks: lvm: allow volume groups on SAN LUNs and multipath maps
      disks: lvm: refuse to destroy the volume group of a shared storage
      disks: allow wiping a SAN LUN that no storage uses
      api: scan: report the process that has a SAN LUN open

 debian/control                                |   3 +-
 src/PVE/API2/Disks.pm                         |  46 +-
 src/PVE/API2/Disks/LVM.pm                     |  80 ++-
 src/PVE/API2/ISCSI.pm                         | 166 +++++
 src/PVE/API2/Makefile                         |   2 +
 src/PVE/API2/Multipath.pm                     | 451 ++++++++++++++
 src/PVE/API2/Storage/Scan.pm                  | 244 ++++++++
 src/PVE/CLI/pvesm.pm                          |  15 +
 src/PVE/Diskmanage.pm                         | 383 ++++++++++--
 src/PVE/ISCSI/Topology.pm                     |  89 +++
 src/PVE/Makefile                              |   6 +
 src/PVE/Multipath.pm                          | 213 +++++++
 src/PVE/Multipath/Config.pm                   | 209 +++++++
 src/PVE/Multipath/Generator.pm                | 128 ++++
 src/PVE/Multipath/Identity.pm                 |  44 ++
 src/PVE/Multipath/Status.pm                   | 228 +++++++
 src/PVE/Storage.pm                            |   2 +-
 src/PVE/Storage/ISCSIPlugin.pm                | 219 ++++---
 src/PVE/Storage/LVMPlugin.pm                  | 156 ++++-
 src/PVE/Storage/Makefile                      |   3 +-
 src/PVE/Storage/SAN.pm                        | 457 ++++++++++++++
 src/test/Makefile                             |  37 +-
 src/test/disk_api_test.pm                     | 314 ++++++++++
 src/test/disk_tests/iscsi/disklist            |   1 +
 .../disk_tests/iscsi/disklist_expected.json   |  19 +
 src/test/disk_tests/iscsi/lsblk               |   5 +
 src/test/disk_tests/iscsi/sda/device/model    |   1 +
 src/test/disk_tests/iscsi/sda/device/vendor   |   1 +
 .../disk_tests/iscsi/sda/queue/rotational     |   1 +
 src/test/disk_tests/iscsi/sda/size            |   1 +
 src/test/disk_tests/iscsi/sda_udevadm         |  21 +
 src/test/disk_tests/multipath/disklist        |  11 +
 .../multipath/disklist_expected.json          | 107 ++++
 src/test/disk_tests/multipath/dm-0/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-0/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-0/size       |   1 +
 src/test/disk_tests/multipath/dm-0_slaves     |   4 +
 src/test/disk_tests/multipath/dm-1/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-1/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-1/size       |   1 +
 src/test/disk_tests/multipath/dm-1_slaves     |   4 +
 src/test/disk_tests/multipath/dm-2/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-2/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-2/size       |   1 +
 src/test/disk_tests/multipath/dm-2_slaves     |   0
 src/test/disk_tests/multipath/dm-3/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-3/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-3/size       |   1 +
 src/test/disk_tests/multipath/dm-3_slaves     |   0
 src/test/disk_tests/multipath/dm-4/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-4/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-4/size       |   1 +
 src/test/disk_tests/multipath/dm-4_slaves     |   0
 src/test/disk_tests/multipath/lsblk           |  77 +++
 src/test/disk_tests/multipath/lvs             |   0
 src/test/disk_tests/multipath/mounts          |   1 +
 .../multipath/multipath_expected.json         |  59 ++
 src/test/disk_tests/multipath/multipathd      | 124 ++++
 .../multipath/multipathd_status_expected.json |  40 ++
 .../nvme-subsystem/nvme-subsys0/nvme3/address |   1 +
 .../nvme-subsys0/nvme3/nvme2c3n1/ana_state    |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme3/state   |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/address |   1 +
 .../nvme-subsys0/nvme4/nvme2c4n1/ana_state    |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/state   |   1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/address |   1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/state   |   1 +
 .../disk_tests/multipath/nvme8n1/device/model |   1 +
 .../multipath/nvme8n1/device/transport        |   1 +
 .../multipath/nvme8n1/queue/rotational        |   1 +
 src/test/disk_tests/multipath/nvme8n1/size    |   1 +
 src/test/disk_tests/multipath/nvme8n1_udevadm |  14 +
 .../disk_tests/multipath/nvme9n1/device/model |   1 +
 .../multipath/nvme9n1/device/nvme5/transport  |   1 +
 .../multipath/nvme9n1/device/vendor           |   1 +
 .../multipath/nvme9n1/queue/rotational        |   1 +
 src/test/disk_tests/multipath/nvme9n1/size    |   1 +
 src/test/disk_tests/multipath/nvme9n1_udevadm |  12 +
 .../multipath/nvme_path_status_expected.json  |  19 +
 src/test/disk_tests/multipath/partlist        |   0
 src/test/disk_tests/multipath/pvs             |   1 +
 .../disk_tests/multipath/sda/device/model     |   1 +
 .../disk_tests/multipath/sda/device/vendor    |   1 +
 .../disk_tests/multipath/sda/holders/holder   |   1 +
 .../disk_tests/multipath/sda/queue/rotational |   1 +
 src/test/disk_tests/multipath/sda/size        |   1 +
 src/test/disk_tests/multipath/sda_udevadm     |  18 +
 .../disk_tests/multipath/sdb/device/model     |   1 +
 .../disk_tests/multipath/sdb/device/vendor    |   1 +
 .../disk_tests/multipath/sdb/holders/holder   |   1 +
 .../disk_tests/multipath/sdb/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdb/size        |   1 +
 src/test/disk_tests/multipath/sdb_udevadm     |  18 +
 .../disk_tests/multipath/sdc/device/model     |   1 +
 .../disk_tests/multipath/sdc/device/vendor    |   1 +
 .../disk_tests/multipath/sdc/holders/holder   |   1 +
 .../disk_tests/multipath/sdc/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdc/size        |   1 +
 src/test/disk_tests/multipath/sdc_udevadm     |  18 +
 .../disk_tests/multipath/sdd/device/model     |   1 +
 .../disk_tests/multipath/sdd/device/vendor    |   1 +
 .../disk_tests/multipath/sdd/holders/holder   |   1 +
 .../disk_tests/multipath/sdd/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdd/size        |   1 +
 src/test/disk_tests/multipath/sdd_udevadm     |  18 +
 src/test/disk_tests/multipath/zpool           |   1 +
 .../disk_tests/sas/disklist_expected.json     |   1 +
 src/test/disk_tests/sas/lsblk                 |   5 +
 src/test/disklist_test.pm                     | 179 +++++-
 src/test/multipath-three-states.json          |  52 ++
 src/test/plugin_properties_test.pm            |   1 +
 src/test/run_disk_api_tests.pl                |  11 +
 src/test/run_iscsi_activation_tests.pl        | 109 ++++
 src/test/run_lun_identity_tests.pl            |  57 ++
 src/test/run_multipath_api_tests.pl           | 584 ++++++++++++++++++
 src/test/run_multipath_tests.pl               | 175 ++++++
 src/test/run_san_api_tests.pl                 | 124 ++++
 src/test/run_san_library_tests.pl             | 135 ++++
 src/test/run_san_lun_scan_tests.pl            | 334 ++++++++++
 src/test/run_san_nvme_tests.pl                | 120 ++++
 src/test/run_san_taint_tests.pl               |  60 ++
 src/test/run_san_wipe_tests.pl                | 271 ++++++++
 src/test/run_san_write_check_tests.pl         | 219 +++++++
 src/test/run_test_lvm_base_activation.pl      | 121 ++++
 src/test/run_test_lvm_base_volume.pl          |  16 +-
 src/test/run_test_lvm_create.pl               |  46 ++
 126 files changed, 6566 insertions(+), 197 deletions(-)

pve-docs:

Thomas Lamprecht (2):
      storage: document the cluster-wide multipath management
      storage: multipath: describe the use shown for an open LUN

 pmxcfs.adoc                  |   2 +
 pve-storage-iscsi.adoc       |  11 ++
 pve-storage-iscsidirect.adoc |   2 +-
 pve-storage-lvm.adoc         |   3 +
 pve-storage-multipath.adoc   | 313 +++++++++++++++++++++++++++++++++++
 pvesm.adoc                   |  18 +-
 6 files changed, 343 insertions(+), 6 deletions(-)

pve-manager:

Dietmar Maurer (2):
      api: nodes: expose the iSCSI status
      ui: node: san: show iSCSI targets and sessions

Thomas Lamprecht (13):
      pvestatd: apply the multipath configuration and report the node status
      report: add the managed multipath configuration
      api: cluster: add the multipath endpoints
      ui: dc: add a SAN view
      ui: storage: iscsi: add the multipath option
      ui: lvm: enable shared when a base storage is selected
      ui: node: add SAN LUNs panel
      ui: node: san: wipe a LUN that no storage uses
      ui: dc: san: add a guided setup for shared LVM on iSCSI
      ui: dc: san: add a guided setup for shared LVM on Fibre Channel
      ui: storage: point the iSCSI and LVM add dialogs to the SAN view
      ui: san: show the guest or process that has a LUN open
      ui: node: san: add a column for the target or subsystem of a LUN

 PVE/API2/Cluster.pm                           |   7 +
 PVE/API2/Nodes.pm                             |   7 +
 PVE/Report.pm                                 |   3 +
 PVE/Service/pvestatd.pm                       |   7 +
 www/manager6/Makefile                         |  12 +
 www/manager6/SANUtils.js                      | 232 ++++++++++
 www/manager6/Utils.js                         |  19 +
 www/manager6/dc/Config.js                     |  23 +-
 www/manager6/dc/MultipathWwidEdit.js          |  81 ++++
 www/manager6/dc/SAN.js                        | 400 ++++++++++++++++++
 www/manager6/node/Config.js                   |  24 ++
 www/manager6/node/ISCSITargets.js             | 150 +++++++
 www/manager6/node/LVM.js                      |   5 +
 www/manager6/node/SANLuns.js                  | 233 ++++++++++
 www/manager6/storage/Base.js                  |   5 +
 www/manager6/storage/IScsiEdit.js             |  46 ++
 www/manager6/storage/LVMEdit.js               |   6 +
 www/manager6/storage/wizard/FibreChannel.js   | 187 ++++++++
 www/manager6/storage/wizard/IScsi.js          | 297 +++++++++++++
 www/manager6/storage/wizard/LunSelect.js      | 224 ++++++++++
 www/manager6/storage/wizard/NodeIdentities.js |  94 ++++
 www/manager6/storage/wizard/Wizard.js         | 298 +++++++++++++
 www/manager6/window/SANLunState.js            | 119 ++++++
 www/manager6/window/SANLunWipe.js             |  64 +++
 24 files changed, 2537 insertions(+), 6 deletions(-)




^ permalink raw reply	[flat|nested] 45+ messages in thread

end of thread, other threads:[~2026-11-19 19:55 UTC | newest]

Thread overview: 45+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-11-18 20:25 [PATCH v7 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 cluster 01/43] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 02/43] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 03/43] diskmanage: qualify NVMe over Fabrics transport Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 04/43] diskmanage: optionally include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 05/43] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 06/43] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 07/43] multipath: add a library around multipathd Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 08/43] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 09/43] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 10/43] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 11/43] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 12/43] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 13/43] multipath: publish per-node status Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 14/43] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 15/43] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-18 20:25 ` [PATCH v7 storage 16/43] diskmanage: look up the requested disks by name Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 17/43] diskmanage: read the udev data of all disks with one call Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 18/43] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 19/43] pvesm: expose the " Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 20/43] api: add node-level iSCSI status Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 21/43] api: scan: name the portal of an iSCSI path Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 22/43] disks: lvm: drop unused imports Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 23/43] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 24/43] disks: lvm: refuse to destroy the volume group of a shared storage Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 25/43] disks: allow wiping a SAN LUN that no storage uses Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 storage 26/43] api: scan: report the process that has a SAN LUN open Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 docs 27/43] storage: document the cluster-wide multipath management Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 docs 28/43] storage: multipath: describe the use shown for an open LUN Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 29/43] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 30/43] report: add the managed multipath configuration Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 31/43] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 32/43] api: nodes: expose the iSCSI status Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 33/43] ui: dc: add a SAN view Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 34/43] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 35/43] ui: lvm: enable shared when a base storage is selected Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 36/43] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 37/43] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 38/43] ui: node: san: show iSCSI targets and sessions Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 39/43] ui: dc: san: add a guided setup for shared LVM on iSCSI Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 40/43] ui: dc: san: add a guided setup for shared LVM on Fibre Channel Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 41/43] ui: storage: point the iSCSI and LVM add dialogs to the SAN view Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 42/43] ui: san: show the guest or process that has a LUN open Thomas Lamprecht
2026-11-18 20:26 ` [PATCH v7 manager 43/43] ui: node: san: add a column for the target or subsystem of a LUN Thomas Lamprecht
2026-11-19 19:49 ` superseded: [PATCH v7 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal