This is v5 of the combined and reduced series of the cluster-wide
multipath work [0][1] and Dietmar's RFC for guided remote storage setup
and SAN visibility [2].

Most changes since v4 [3] come from feedback from Blockbridge – a
third-party storage plugin vendor. Their plugin attaches one LUN per
guest disk, so a plain upgrade hits nodes with several hundred multipath
maps that are not ours:

 - The iSCSI storage option is named 'managed-multipath' now. Their
   plugin defines a 'multipath' property, and a property that two
   plugins define stops PVE::Storage from loading. Per-plugin property
   isolation would be the real answer, but a single plugin that opts
   in switches the storage API to a schema in which updates need the
   type, so 'pvesm set' and the edit dialogs fail for all storages of
   that node. We (I and/or Max, Wolfgang) will look into completing that
   separately.
 - A node reports the maps that Proxmox VE manages or has a storage
   on, and counts the rest. Before, every map got a row, and beyond
   about 185 of them the report no longer fit into the 32 KiB of a
   value in the node key-value store, which cost the node the state of
   our LUNs as well.
 - The LUN scan no longer queries udev for the paths of a map. With
   1000 additional maps on a node that was one udevadm call for each of
   2000 path devices and 13 seconds per scan, for views that poll it
   every few seconds. It is 2 seconds now.
 - Writing to a LUN, for a new volume group or a wipe, is refused while
   a process of the node has it open. A guest that got the LUN from a
   plugin or by its device path is neither a holder nor a storage
   reference, and such a node lists hundreds of them. v3 had a broader
   census of device users, which I dropped in v4 with the rest of that
   machinery; this is the cheap part of it.

The alleged long multipathd query time on every status pass I could not
reproduce as a problem, as it took 30 ms for those 1000 maps on a small
nested node and the status loop stayed in its normal cycle.

Overview of what an admin gets with this:

 - Datacenter > Storage > SAN, a new entry below Storage, shows the
   multipath state of every node and of the LUNs that Proxmox VE
   manages or has a storage on, and edits the multipath entries and
   array-specific overrides. I explicitly chose this over the
   client/plugin side of Storage, as we do not have e.g. Ceph or
   ZFS/LVM/... creation in there either. We might want to rethink and
   consolidate our storage interface vs. management story in the
   future, but IMO a partial switch now is not worth it, that would add
   even more potential for confusion than the new SAN view.
 - Its Add Storage menu guides through shared LVM on a LUN: for iSCSI
   it connects or reuses a target, with the initiator names of all
   nodes at hand, for Fibre Channel it takes a LUN the nodes already
   see. Both set up multipath for the LUN and end with its state on
   every node of the new storage.
 - Datacenter > Storage > Add keeps its dialogs. The iSCSI one gets a
   Multipath option and the LVM one enables Shared for a base storage,
   so the same works there in two steps. Both name the SAN view in a
   note whose link opens it, as admins coming from other platforms look
   for their SAN there first.
 - Node > SAN lists the LUNs of a node with their paths and usage, can
   wipe a LUN that no storage uses, and shows the iSCSI sessions.

The rules the series follows since v4, in short: nodes add WWIDs and
maps but never remove them, a write is checked where it happens, lists
do not probe devices, there are no new iSCSI operations, the guided
setup makes the API calls an admin would make by hand, and multipath
management is turned on by the admin. The v4 cover [3] has the reasons
and what each of them costs.

Two things an admin will likely miss: there is no notification when a
LUN loses path redundancy, the state only shows on the SAN pages and in
the API. A node with fewer paths than its iSCSI portals or the expected
paths of the LUN's entry at least shows as degraded there, and a LUN
that only has one path reads "OK (1 path)" instead of optimal. And Fibre
Channel starts at a LUN the nodes already see, the web UI neither lists
the WWPNs of the nodes nor rescans their HBAs; the chapter gives the
commands for both, and the setup points to the rescan.

How it works:

 - /etc/pve/multipath.cfg holds explicit entries per WWID (nodes, alias,
   no-path-retry, expected paths), /etc/pve/multipath-overrides.conf
   array settings in multipath.conf syntax; patch 01 registers
   both. An iSCSI storage with the new 'managed-multipath' option
   supplies its LUNs without entries, a Fibre Channel LUN gets an
   explicit entry unless it has a map already.
 - pvestatd calls one function of pve-storage per pass. It adds the
   WWIDs the node needs to /etc/multipath/wwids, writes the drop-ins
   /etc/multipath/conf.d/pve-*.conf (entries, overrides and one
   generated default, auto_resize grow_only) and reloads multipathd
   when something changed. The same call publishes the state of the
   maps that the node manages or that hold the volume group of a
   storage, and the number of its other maps, through the node
   key-value store (key 'multipath').
 - /cluster/multipath/status aggregates these reports, derives
   'missing' from the configuration and names the storage that requests
   each map; /cluster/multipath/{wwid,overrides} edit the two files.
 - The volumes of an iSCSI storage with the option end in
   dm-uuid-mpath-<wwid> instead of the name of one path, so an LVM
   storage uses them through the existing 'base' mechanism.
 - /nodes/{node}/scan/san-luns and 'pvesm scan san-luns' return one row
   per LUN with a WWID, /nodes/{node}/iscsi/{status,target} the
   read-only session view.
 - Volume group creation and wipe run under a cluster lock per LUN
   (cfs_lock_domain) and do not hold the storage configuration lock
   while they write. Adding an LVM storage with a new base volume still
   does, as before. Both refuse a LUN that a process of the node has
   open.
 - multipath-tools becomes a Recommends of libpve-storage-perl. Nodes
   without it report that; plain iSCSI and LVM are unaffected.

Patches:

 - cluster 01: register the two configuration files
 - storage 02-22: helpers for the disk and iSCSI session inventory
   (mostly Dietmar's), the multipath library and configuration, the
   iSCSI option, the per-node apply and status with their API, the LUN
   inventory, the read-only iSCSI status, volume groups on LUNs and the
   wipe, in that order
 - docs 23: the multipath chapter, rewritten around tasks
 - manager 24-36: the pvestatd call, report and API mounts, then
   the views, the two dialog changes, the two guided setups and the
   note in the add dialogs

Changes since v4 [3]:

 - renamed the iSCSI storage option 'multipath' to 'managed-multipath'
   in storage.cfg, API and CLI; the web UI keeps the label Multipath
 - the node report has rows for maps with an explicit entry for the
   node, of an iSCSI storage with the option, that are the base volume
   of an LVM storage or that hold the volume group of a storage, and
   the new 'other-maps' count for the rest. The SAN panel shows that
   count in a column of the node list once a node has such maps. The
   volume groups come from LVM's hint file; a node that leaves maps
   out without one says so, and counts as unknown instead of missing
   for a LUN that only a volume group relates to a storage there. A
   report over the size limit keeps the initiator name, and the
   chapter names the limit
 - the LUN scan leaves the paths of maps out before the disk
   enumeration
 - volume group creation on a LUN and the wipe check for processes
   that have the LUN open. That reads /proc/<pid>/fd, so it does not
   see an open through another device node, for example one of a
   container
 - both also stop if a device name they use no longer means the LUN
   they hold open, the wipe also for the partitions it clears and for
   its exclusive descriptor. Creating a volume group checked and
   initialized the kernel name it was called with, but cleared the
   first sector through the by-id name, and a map can get another name
   while the lock is awaited
 - a volume group on a partition of a multipath map counts for the map
 - the Fibre Channel setup offers SCSI LUNs only. It also listed
   NVMe/FC namespaces, which the cluster-wide status does not cover, so
   its closing window stayed empty for them
 - the LUN step only asks to wipe data that is no longer needed, and
   the chapter says how to keep a volume group that a LUN already has
 - from an automated review of v4: the multipath values of the LUN
   scan are described in the API, the portal label is translatable,
   imports are grouped, the new iSCSI topology module uses signatures,
   WWID and map UUID patterns use ASCII digit classes, three statement
   modifiers after multi-line calls became blocks, some comments and
   commit messages got reworded
 - rebased onto current master in pve-storage, pve-manager and
   pve-cluster

When applying, versioned dependencies have to be set: pve-manager on
libpve-storage-perl, and libpve-storage-perl (also as build dependency)
on the libpve-cluster-perl with patch 01, as PVE::Storage
registers the two files when it is loaded. If the bound for LVM status
commands [4] gets applied too, whichever is applied second has to pass
the status cache to the two lvm_vgs() calls of the base volume
activation, they can block a status pass otherwise.

The per-node target and portal series [5][6] are independent of this
one. It takes the LUNs of an iSCSI storage from the sessions of its one
target, so if a storage can have several targets per node, whichever is
applied second has to cover that.

For v4 I tested this on a six-node nested cluster attached to a NetApp
AFF A20 with three iSCSI portals and to Linux LIO targets with two: the
guided iSCSI setup with a new and with a reused connection storage, the
same through the plain dialogs and from the CLI as documented, a LUN
that one node is not allowed to see and gets access later, the Fibre
Channel flow through the web UI, also as an administrator other than
root@pam, a guest on the resulting storages (snapshot, rollback, online
resize, live migration, one path cut under I/O), growing a LUN, wipe and
its refusals, one path and all paths down with queued I/O, a stopped
multipathd, a node reboot and the documented LUN removal. The lab has no
FC hardware, so I emulated it with software FCoE in VN2VN mode and an
LIO tcm_fc target on two fabrics: the nodes get real FC host and remote
port objects, and the documented WWPN listing, rescan and LUN growth
work there as written. The guided Fibre Channel setup ran on such a LUN,
with one node on one fabric only and one node that saw the LUN only
after the rescan. The setup records the paths it sees in the LUN's
entry, so the node on one fabric shows as degraded, and a fabric cut
stays degraded also after the kernel removed the lost paths (66 seconds
dev_loss_tmo of the LIO profile). Real HBA drivers were not tested. Most
of that ran with the NVMe over Fabrics series on top and with the LVM
status patch [4] applied, the series alone ran on one node of that
cluster for the guided setups, the CLI procedure and the views. Without
[4] a stuck LVM command blocks pvestatd as on master.

For v5 I upgraded that cluster from the v4 build, renamed the option in
its storage.cfg and checked that the storages on the NetApp and LIO LUNs
stay active with their guests running. I emulated the plugin vendor's
case with scsi_debug, two hosts with the same LUN identities, so 1000
additional maps with two paths each on one node: report, status loop and
scan before and after the changes, both SAN views after them. The wipe
refusal for an open LUN ran on such a map, with a process holding it
open, the one of volume group creation on a LIO LUN, followed by the
creation without the process. A hand-made map under a shared LVM storage
on two nodes covered the case of a node without LVM hints and the one of
a volume group on a partition of the map. The guided iSCSI setup ran
once more on a NetApp LUN, from wiping its old volume group to the
documented removal. The rest of the list above was not repeated for v5,
although the changes touch what those flows use: the LUN scan, the
status report, the write checks and the LUN selection of the Fibre
Channel setup.

[0]: https://lore.proxmox.com/pve-devel/20260626121000.2095591-1-t.lamprecht@proxmox.com/
[1]: https://lore.proxmox.com/pve-devel/20260703124707.1172980-2-t.lamprecht@proxmox.com/
[2]: https://lore.proxmox.com/pve-devel/20260731102156.3947857-1-dietmar@proxmox.com/
[3]: https://lore.proxmox.com/pve-devel/20261113030146.1559030-1-t.lamprecht@proxmox.com/
[4]: https://lore.proxmox.com/pve-devel/20261111015217.941220-1-t.lamprecht@proxmox.com/
[5]: https://lore.proxmox.com/pve-devel/20260430173220.441001-1-m.limbeck@proxmox.com/
[6]: https://lore.proxmox.com/pve-devel/20260804090819.2136483-1-dietmar@proxmox.com/

pve-cluster:

Thomas Lamprecht (1):
      cfs: observe the multipath configuration files

 src/PVE/Cluster.pm  | 2 ++
 src/pmxcfs/status.c | 2 ++
 2 files changed, 4 insertions(+)

pve-storage:

Dietmar Maurer (8):
      diskmanage: collect disk transport type from lsblk
      diskmanage: qualify NVMe over fabrics transport
      diskmanage: optionally include iSCSI session devices in disk enumeration
      diskmanage: collect native NVMe multipath path state
      iscsi: factor out session device map from device list
      diskmanage: add helper to list multipath devices
      pvesm: expose the SAN LUN inventory
      api: add node-level iSCSI status

Thomas Lamprecht (13):
      multipath: add a library around multipathd
      multipath: add a cluster-wide configuration
      iscsi: add an option to manage storage LUNs with multipath
      lvm: activate a missing base volume before using the volume group
      multipath: apply the configuration on every node
      multipath: publish per-node status
      api: add endpoints for the cluster-wide multipath configuration
      api: multipath: add the cluster-wide health status
      api: scan: add a SAN LUN inventory
      disks: lvm: drop unused imports
      disks: lvm: allow volume groups on SAN LUNs and multipath maps
      disks: lvm: refuse to destroy the volume group of a shared storage
      disks: allow wiping a SAN LUN that no storage uses

 debian/control                                |   3 +-
 src/PVE/API2/Disks.pm                         |  36 +-
 src/PVE/API2/Disks/LVM.pm                     |  64 ++-
 src/PVE/API2/ISCSI.pm                         | 166 +++++++
 src/PVE/API2/Makefile                         |   2 +
 src/PVE/API2/Multipath.pm                     | 454 ++++++++++++++++++
 src/PVE/API2/Storage/Scan.pm                  | 202 ++++++++
 src/PVE/CLI/pvesm.pm                          |  14 +
 src/PVE/Diskmanage.pm                         | 277 +++++++++--
 src/PVE/ISCSI/Topology.pm                     |  86 ++++
 src/PVE/Makefile                              |   6 +
 src/PVE/Multipath.pm                          | 213 ++++++++
 src/PVE/Multipath/Config.pm                   | 205 ++++++++
 src/PVE/Multipath/Generator.pm                | 114 +++++
 src/PVE/Multipath/Identity.pm                 |  44 ++
 src/PVE/Multipath/Status.pm                   | 220 +++++++++
 src/PVE/Storage/ISCSIPlugin.pm                | 212 ++++----
 src/PVE/Storage/LVMPlugin.pm                  | 146 +++++-
 src/PVE/Storage/Makefile                      |   3 +-
 src/PVE/Storage/SAN.pm                        | 352 ++++++++++++++
 src/test/Makefile                             |  34 +-
 src/test/disk_api_test.pm                     | 256 ++++++++++
 src/test/disk_tests/iscsi/disklist            |   1 +
 .../disk_tests/iscsi/disklist_expected.json   |  19 +
 src/test/disk_tests/iscsi/lsblk               |   5 +
 src/test/disk_tests/iscsi/sda/device/model    |   1 +
 src/test/disk_tests/iscsi/sda/device/vendor   |   1 +
 .../disk_tests/iscsi/sda/queue/rotational     |   1 +
 src/test/disk_tests/iscsi/sda/size            |   1 +
 src/test/disk_tests/iscsi/sda_udevadm         |  21 +
 src/test/disk_tests/multipath/disklist        |  11 +
 .../multipath/disklist_expected.json          | 107 +++++
 src/test/disk_tests/multipath/dm-0/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-0/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-0/size       |   1 +
 src/test/disk_tests/multipath/dm-0_slaves     |   4 +
 src/test/disk_tests/multipath/dm-1/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-1/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-1/size       |   1 +
 src/test/disk_tests/multipath/dm-1_slaves     |   4 +
 src/test/disk_tests/multipath/dm-2/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-2/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-2/size       |   1 +
 src/test/disk_tests/multipath/dm-2_slaves     |   0
 src/test/disk_tests/multipath/dm-3/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-3/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-3/size       |   1 +
 src/test/disk_tests/multipath/dm-3_slaves     |   0
 src/test/disk_tests/multipath/dm-4/dm/name    |   1 +
 src/test/disk_tests/multipath/dm-4/dm/uuid    |   1 +
 src/test/disk_tests/multipath/dm-4/size       |   1 +
 src/test/disk_tests/multipath/dm-4_slaves     |   0
 src/test/disk_tests/multipath/lsblk           |  77 +++
 src/test/disk_tests/multipath/lvs             |   0
 src/test/disk_tests/multipath/mounts          |   1 +
 .../multipath/multipath_expected.json         |  59 +++
 src/test/disk_tests/multipath/multipathd      | 124 +++++
 .../multipath/multipathd_status_expected.json |  40 ++
 .../nvme-subsystem/nvme-subsys0/nvme3/address |   1 +
 .../nvme-subsys0/nvme3/nvme2c3n1/ana_state    |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme3/state   |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/address |   1 +
 .../nvme-subsys0/nvme4/nvme2c4n1/ana_state    |   1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/state   |   1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/address |   1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/state   |   1 +
 .../disk_tests/multipath/nvme8n1/device/model |   1 +
 .../multipath/nvme8n1/device/transport        |   1 +
 .../multipath/nvme8n1/queue/rotational        |   1 +
 src/test/disk_tests/multipath/nvme8n1/size    |   1 +
 src/test/disk_tests/multipath/nvme8n1_udevadm |  14 +
 .../disk_tests/multipath/nvme9n1/device/model |   1 +
 .../multipath/nvme9n1/device/transport        |   1 +
 .../multipath/nvme9n1/device/vendor           |   1 +
 .../multipath/nvme9n1/queue/rotational        |   1 +
 src/test/disk_tests/multipath/nvme9n1/size    |   1 +
 src/test/disk_tests/multipath/nvme9n1_udevadm |  12 +
 .../multipath/nvme_path_status_expected.json  |  19 +
 src/test/disk_tests/multipath/partlist        |   0
 src/test/disk_tests/multipath/pvs             |   1 +
 .../disk_tests/multipath/sda/device/model     |   1 +
 .../disk_tests/multipath/sda/device/vendor    |   1 +
 .../disk_tests/multipath/sda/holders/holder   |   1 +
 .../disk_tests/multipath/sda/queue/rotational |   1 +
 src/test/disk_tests/multipath/sda/size        |   1 +
 src/test/disk_tests/multipath/sda_udevadm     |  18 +
 .../disk_tests/multipath/sdb/device/model     |   1 +
 .../disk_tests/multipath/sdb/device/vendor    |   1 +
 .../disk_tests/multipath/sdb/holders/holder   |   1 +
 .../disk_tests/multipath/sdb/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdb/size        |   1 +
 src/test/disk_tests/multipath/sdb_udevadm     |  18 +
 .../disk_tests/multipath/sdc/device/model     |   1 +
 .../disk_tests/multipath/sdc/device/vendor    |   1 +
 .../disk_tests/multipath/sdc/holders/holder   |   1 +
 .../disk_tests/multipath/sdc/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdc/size        |   1 +
 src/test/disk_tests/multipath/sdc_udevadm     |  18 +
 .../disk_tests/multipath/sdd/device/model     |   1 +
 .../disk_tests/multipath/sdd/device/vendor    |   1 +
 .../disk_tests/multipath/sdd/holders/holder   |   1 +
 .../disk_tests/multipath/sdd/queue/rotational |   1 +
 src/test/disk_tests/multipath/sdd/size        |   1 +
 src/test/disk_tests/multipath/sdd_udevadm     |  18 +
 src/test/disk_tests/multipath/zpool           |   1 +
 .../disk_tests/sas/disklist_expected.json     |   1 +
 src/test/disk_tests/sas/lsblk                 |   5 +
 src/test/disklist_test.pm                     | 107 ++++-
 src/test/multipath-three-states.json          |  52 ++
 src/test/run_disk_api_tests.pl                |  11 +
 src/test/run_iscsi_activation_tests.pl        |  86 ++++
 src/test/run_lun_identity_tests.pl            |  48 ++
 src/test/run_multipath_api_tests.pl           | 444 +++++++++++++++++
 src/test/run_multipath_tests.pl               | 169 +++++++
 src/test/run_san_api_tests.pl                 |  94 ++++
 src/test/run_san_library_tests.pl             | 135 ++++++
 src/test/run_san_lun_scan_tests.pl            | 197 ++++++++
 src/test/run_san_nvme_tests.pl                | 108 +++++
 src/test/run_san_taint_tests.pl               |  60 +++
 src/test/run_san_wipe_tests.pl                | 190 ++++++++
 src/test/run_test_lvm_base_activation.pl      | 118 +++++
 src/test/run_test_lvm_base_conflicts.pl       | 233 ++++++---
 src/test/run_test_lvm_create.pl               |  41 ++
 123 files changed, 5622 insertions(+), 234 deletions(-)

pve-docs:

Thomas Lamprecht (1):
      storage: document the cluster-wide multipath management

 pmxcfs.adoc                  |   2 +
 pve-storage-iscsi.adoc       |  11 ++
 pve-storage-iscsidirect.adoc |   2 +-
 pve-storage-lvm.adoc         |   3 +
 pve-storage-multipath.adoc   | 282 +++++++++++++++++++++++++++++++++++
 pvesm.adoc                   |  18 ++-
 6 files changed, 312 insertions(+), 6 deletions(-)

pve-manager:

Dietmar Maurer (2):
      api: nodes: expose the iSCSI status
      ui: node: san: show iSCSI targets and sessions

Thomas Lamprecht (11):
      pvestatd: apply the multipath configuration and report the node status
      report: add the managed multipath configuration
      api: cluster: add the multipath endpoints
      ui: dc: add a SAN view
      ui: storage: iscsi: add the multipath option
      ui: lvm: enable shared when a base storage is selected
      ui: node: add SAN LUNs panel
      ui: node: san: wipe a LUN that no storage uses
      ui: dc: san: add a guided setup for shared LVM on iSCSI
      ui: dc: san: add a guided setup for shared LVM on Fibre Channel
      ui: storage: point the iSCSI and LVM add dialogs to the SAN view

 PVE/API2/Cluster.pm                           |   7 +
 PVE/API2/Nodes.pm                             |   7 +
 PVE/Report.pm                                 |   3 +
 PVE/Service/pvestatd.pm                       |   7 +
 www/manager6/Makefile                         |  12 +
 www/manager6/SANUtils.js                      | 161 ++++++++
 www/manager6/Utils.js                         |  14 +
 www/manager6/dc/Config.js                     |  23 +-
 www/manager6/dc/MultipathWwidEdit.js          |  81 ++++
 www/manager6/dc/SAN.js                        | 347 ++++++++++++++++++
 www/manager6/node/Config.js                   |  24 ++
 www/manager6/node/ISCSITargets.js             | 122 ++++++
 www/manager6/node/SANLuns.js                  | 184 ++++++++++
 www/manager6/storage/Base.js                  |   5 +
 www/manager6/storage/IScsiEdit.js             |  46 +++
 www/manager6/storage/LVMEdit.js               |   6 +
 www/manager6/storage/wizard/FibreChannel.js   | 162 ++++++++
 www/manager6/storage/wizard/IScsi.js          | 272 ++++++++++++++
 www/manager6/storage/wizard/LunSelect.js      | 179 +++++++++
 www/manager6/storage/wizard/NodeIdentities.js |  83 +++++
 www/manager6/storage/wizard/Wizard.js         | 258 +++++++++++++
 www/manager6/window/SANLunState.js            | 115 ++++++
 www/manager6/window/SANLunWipe.js             |  53 +++
 23 files changed, 2165 insertions(+), 6 deletions(-)




             reply	other threads:[~2026-11-16  1:25 UTC|newest]

Thread overview: 38+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-11-16  1:23 Thomas Lamprecht [this message]
2026-11-16  1:23 ` [PATCH v5 cluster 01/36] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 02/36] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 03/36] diskmanage: qualify NVMe over fabrics transport Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 04/36] diskmanage: optionally include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 05/36] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 06/36] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 07/36] multipath: add a library around multipathd Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 08/36] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 09/36] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 10/36] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 11/36] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 12/36] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 13/36] multipath: publish per-node status Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 14/36] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 15/36] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 16/36] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 17/36] pvesm: expose the " Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 18/36] api: add node-level iSCSI status Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 19/36] disks: lvm: drop unused imports Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 20/36] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 21/36] disks: lvm: refuse to destroy the volume group of a shared storage Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 storage 22/36] disks: allow wiping a SAN LUN that no storage uses Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 docs 23/36] storage: document the cluster-wide multipath management Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 24/36] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 25/36] report: add the managed multipath configuration Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 26/36] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 27/36] api: nodes: expose the iSCSI status Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 28/36] ui: dc: add a SAN view Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 29/36] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 30/36] ui: lvm: enable shared when a base storage is selected Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 31/36] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 32/36] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 33/36] ui: node: san: show iSCSI targets and sessions Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 34/36] ui: dc: san: add a guided setup for shared LVM on iSCSI Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 35/36] ui: dc: san: add a guided setup for shared LVM on Fibre Channel Thomas Lamprecht
2026-11-16  1:23 ` [PATCH v5 manager 36/36] ui: storage: point the iSCSI and LVM add dialogs to the SAN view Thomas Lamprecht
2026-11-18  8:11 ` superseded: [PATCH v5 cluster,storage,docs,manager 00/36] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20261116012355.3187417-1-t.lamprecht@proxmox.com \
    --to=t.lamprecht@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal