From: Thomas Lamprecht <t.lamprecht@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [PATCH v5 manager 35/36] ui: dc: san: add a guided setup for shared LVM on Fibre Channel
Date: Mon, 16 Nov 2026 02:23:44 +0100 [thread overview]
Message-ID: <20261116012355.3187417-36-t.lamprecht@proxmox.com> (raw)
In-Reply-To: <20261116012355.3187417-1-t.lamprecht@proxmox.com>
Fibre Channel LUNs show up as block devices on the nodes, without a
storage that connects to them, so Datacenter > Storage > Add has no
dialog to start from. Add a Fibre Channel entry to the guided setup of
the SAN view: select the LUN, name the volume group and storage,
confirm. It offers SCSI LUNs only. An NVMe/FC namespace uses the
native multipath of the kernel and has no storage that connects it,
so the cluster-wide status could not show its state on the nodes.
The setup enables multipath for the LUN if needed and waits for its map,
then creates the volume group through the node serving the web UI and
adds the shared LVM storage. It adds the storage itself instead of
letting the node disk API do so, as that would add it for all nodes and
without the snapshot setting, to be changed afterwards.
A Fibre Channel LUN has no storage that knows how many paths a node
should have. So an entry the setup adds expects as many paths as the map
has on that node, and a node zoned to fewer fabrics or one that lost a
path shows the LUN as degraded.
A LUN with a volume group cannot be selected again, so the setup
checks that the storage ID is free before it changes anything.
Nodes do not scan for a LUN that is mapped to them after their login
to the array. So the LUN step names the rescan of the Fibre Channel
hosts and links to its documentation, and the closing window names it
for a node that stays missing.
Co-authored-by: Dietmar Maurer <dietmar@proxmox.com>
Signed-off-by: Dietmar Maurer <dietmar@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
---
www/manager6/Makefile | 1 +
www/manager6/dc/SAN.js | 5 +-
www/manager6/storage/wizard/FibreChannel.js | 162 ++++++++++++++++++++
www/manager6/storage/wizard/LunSelect.js | 23 ++-
www/manager6/storage/wizard/Wizard.js | 90 ++++++++++-
www/manager6/window/SANLunState.js | 10 +-
6 files changed, 277 insertions(+), 14 deletions(-)
create mode 100644 www/manager6/storage/wizard/FibreChannel.js
diff --git a/www/manager6/Makefile b/www/manager6/Makefile
index c7cefeacc..ebdc3f802 100644
--- a/www/manager6/Makefile
+++ b/www/manager6/Makefile
@@ -389,6 +389,7 @@ JSSRC= \
storage/wizard/LunSelect.js \
storage/wizard/NodeIdentities.js \
storage/wizard/IScsi.js \
+ storage/wizard/FibreChannel.js \
Workspace.js \
# end of JSSRC list
diff --git a/www/manager6/dc/SAN.js b/www/manager6/dc/SAN.js
index a8ef4cd5b..2adeba227 100644
--- a/www/manager6/dc/SAN.js
+++ b/www/manager6/dc/SAN.js
@@ -106,9 +106,10 @@ Ext.define('PVE.dc.SANView', {
autoShow: true,
apiCallDone: (success) => success && reload(),
});
- let setupItem = (wizardType) => ({
+ let setupItem = (wizardType, disabled) => ({
text: PVE.storage.wizard.subject(wizardType),
iconCls: 'fa fa-fw fa-building',
+ disabled,
handler: () =>
Ext.create('PVE.storage.wizard.SAN', {
wizardType,
@@ -120,7 +121,7 @@ Ext.define('PVE.dc.SANView', {
{
text: gettext('Add Storage'),
disabled: !allCaps.storage['Datastore.Allocate'],
- menu: [setupItem('iscsi')],
+ menu: [setupItem('iscsi'), setupItem('fc', !canModify)],
},
];
me.items = [
diff --git a/www/manager6/storage/wizard/FibreChannel.js b/www/manager6/storage/wizard/FibreChannel.js
new file mode 100644
index 000000000..99dea67c7
--- /dev/null
+++ b/www/manager6/storage/wizard/FibreChannel.js
@@ -0,0 +1,162 @@
+PVE.storage.wizard.createFC = function (wizard, values, lun) {
+ let fail = (response) => wizard.showError(response.htmlStatus);
+ let create = function (row) {
+ if (wizard.destroyed) {
+ return;
+ }
+ Proxmox.Utils.API2Request({
+ url: `/nodes/${Proxmox.NodeName}/disks/lvm`,
+ method: 'POST',
+ params: { name: values.vgname, device: row['by-id'] || row.devpath },
+ waitMsgTarget: wizard,
+ failure: fail,
+ success: function (response) {
+ if (wizard.destroyed) {
+ return;
+ }
+ wizard.waitForTask(response.result.data, () =>
+ wizard.addLVMStorage(values, (res) =>
+ wizard.stopWithError(
+ res.htmlStatus +
+ '<br>' +
+ gettext(
+ 'The volume group was created, but adding the storage failed. Add it under Datacenter > Storage > Add > LVM with Shared enabled.',
+ ),
+ ),
+ ),
+ );
+ },
+ });
+ };
+ let hasMultipath = (row) => ['manual', 'storage', 'unmanaged'].includes(row.multipath);
+ // Fibre Channel has no storage that knows how many paths a node should have, so an entry the
+ // setup adds expects the paths of this node. A node with fewer paths then shows as degraded.
+ // The wizard remembers the entry it added, so that a retry still sets the expected paths before
+ // it creates the volume group.
+ let expectPaths = function (row) {
+ if (!(row['paths-total'] >= 2)) {
+ delete wizard.addedEntry;
+ create(row);
+ return;
+ }
+ Proxmox.Utils.API2Request({
+ url: `/cluster/multipath/wwid/${encodeURIComponent(lun.wwid)}`,
+ method: 'PUT',
+ params: { 'paths-expected': row['paths-total'] },
+ waitMsgTarget: wizard,
+ failure: fail,
+ success: () => {
+ delete wizard.addedEntry;
+ create(row);
+ },
+ });
+ };
+ let waitForMap = function () {
+ if (wizard.destroyed) {
+ return;
+ }
+ let store = Ext.create('Proxmox.data.UpdateStore', {
+ storeid: 'san-wizard-map',
+ model: 'pve-san-lun',
+ interval: 3000,
+ proxy: { type: 'proxmox', url: `/api2/json/nodes/${Proxmox.NodeName}/scan/san-luns` },
+ });
+ let timer = Ext.defer(function () {
+ store.destroy();
+ if (!wizard.destroyed) {
+ wizard.setLoading(false);
+ wizard.showError(
+ gettext(
+ 'The multipath map did not appear within 90 seconds. Check Node > SAN, then reload the LUN list.',
+ ),
+ );
+ }
+ }, 90000);
+ wizard.on(
+ 'destroy',
+ () => {
+ clearTimeout(timer);
+ if (!store.destroyed) {
+ store.destroy();
+ }
+ },
+ null,
+ { single: true },
+ );
+ wizard.setLoading(gettext('Waiting for the multipath map...'));
+ store.on('load', function (s, records, success, operation) {
+ if (wizard.destroyed) {
+ return;
+ }
+ let row = records?.find((rec) => rec.get('wwid') === lun.wwid)?.data;
+ if (!success || (row && hasMultipath(row))) {
+ clearTimeout(timer);
+ store.destroy();
+ wizard.setLoading(false);
+ if (success) {
+ wizard.down('#luns').down('grid').getSelection()[0].set(row);
+ if (wizard.addedEntry === lun.wwid) {
+ expectPaths(row);
+ } else {
+ create(row);
+ }
+ } else {
+ wizard.showError(Proxmox.Utils.getResponseErrorMessage(operation.getError()));
+ }
+ }
+ });
+ store.startUpdate();
+ };
+ let setup = function () {
+ if (hasMultipath(lun)) {
+ if (wizard.addedEntry === lun.wwid) {
+ expectPaths(lun);
+ } else {
+ create(lun);
+ }
+ } else if (lun.multipath === 'pending' || wizard.addedEntry === lun.wwid) {
+ waitForMap();
+ } else {
+ let params = { wwid: lun.wwid };
+ if (values.nodes) {
+ params.nodes = values.nodes;
+ }
+ Proxmox.Utils.API2Request({
+ url: '/cluster/multipath/wwid',
+ method: 'POST',
+ params,
+ waitMsgTarget: wizard,
+ failure: fail,
+ success: () => {
+ wizard.addedEntry = lun.wwid;
+ waitForMap();
+ },
+ });
+ }
+ };
+ // The storage is added last. Its ID has to be free before anything is created, as the LUN
+ // cannot be selected again once it has a volume group.
+ Proxmox.Utils.API2Request({
+ url: '/storage',
+ method: 'GET',
+ waitMsgTarget: wizard,
+ failure: fail,
+ success: function (response) {
+ if (wizard.destroyed) {
+ return;
+ }
+ if (response.result.data.some((entry) => entry.storage === values.storage)) {
+ wizard.showError(
+ Ext.htmlEncode(
+ Ext.String.format(
+ gettext('Storage ID "{0}" is already in use. Choose another ID.'),
+ values.storage,
+ ),
+ ),
+ );
+ return;
+ }
+ setup();
+ },
+ });
+};
diff --git a/www/manager6/storage/wizard/LunSelect.js b/www/manager6/storage/wizard/LunSelect.js
index d96cde871..0bb7807fd 100644
--- a/www/manager6/storage/wizard/LunSelect.js
+++ b/www/manager6/storage/wizard/LunSelect.js
@@ -22,6 +22,10 @@ Ext.define('PVE.storage.wizard.LunSelect', {
let wizard = me.up('window');
let grid = me.down('grid');
me.rstore.stopUpdate();
+ if (!wizard.connection) {
+ me.rstore.startUpdate();
+ return;
+ }
me.store.setFilters([
{ property: 'iscsi-target', value: wizard.connection.target, exactMatch: true },
]);
@@ -67,6 +71,15 @@ Ext.define('PVE.storage.wizard.LunSelect', {
'A LUN used by a storage cannot be selected. A LUN with data that is no longer needed has to be wiped under Node > SAN first.',
),
},
+ ...(me.rescanNote
+ ? [
+ {
+ xtype: 'component',
+ margin: '0 0 10 0',
+ html: `<span class="pmx-hint">${Ext.htmlEncode(gettext('Note:'))}</span> ${me.rescanNote}`,
+ },
+ ]
+ : []),
{
xtype: 'grid',
flex: 1,
@@ -148,7 +161,15 @@ Ext.define('PVE.storage.wizard.LunSelect', {
me.callParent();
Proxmox.Utils.monStoreErrors(me.down('grid'), me.rstore);
me.mon(me.rstore, 'load', updateSelection);
- me.on('activate', () => me.reload());
+ me.on('activate', function () {
+ if (me.up('window').wizardType === 'fc') {
+ me.down('gridcolumn[dataIndex=iscsi-lun]').hide();
+ me.store.setFilters([
+ { filterFn: (rec) => ['fc', 'fcoe'].includes(rec.get('transport')) },
+ ]);
+ }
+ me.reload();
+ });
me.on('deactivate', () => me.rstore.stopUpdate());
me.on('destroy', () => {
me.store.destroy();
diff --git a/www/manager6/storage/wizard/Wizard.js b/www/manager6/storage/wizard/Wizard.js
index 1f3975b75..3744f1ca1 100644
--- a/www/manager6/storage/wizard/Wizard.js
+++ b/www/manager6/storage/wizard/Wizard.js
@@ -1,7 +1,10 @@
Ext.ns('PVE.storage.wizard');
PVE.storage.wizard.subject = (type) =>
- Ext.String.format(gettext('LVM on {0}'), PVE.Utils.format_storage_type(type));
+ Ext.String.format(
+ gettext('LVM on {0}'),
+ type === 'fc' ? gettext('Fibre Channel') : PVE.Utils.format_storage_type(type),
+ );
PVE.storage.wizard.validateNodes = function () {
let nodes = [].concat(this.getValue() || []).filter(Boolean);
@@ -20,6 +23,11 @@ Ext.define('PVE.storage.wizard.SAN', {
width: 1050,
height: 620,
+ stopWithError: function (message) {
+ this.close();
+ Ext.Msg.alert(gettext('Error'), message);
+ },
+
showError: function (message) {
if (this.destroyed) {
return;
@@ -28,6 +36,24 @@ Ext.define('PVE.storage.wizard.SAN', {
Ext.Msg.alert(gettext('Error'), message);
},
+ waitForTask: function (upid, next) {
+ let me = this;
+ Ext.create('Proxmox.window.TaskProgress', {
+ upid,
+ autoShow: true,
+ taskDone: function (success) {
+ if (me.destroyed) {
+ return;
+ }
+ if (success) {
+ next();
+ } else {
+ me.down('#submit').enable();
+ }
+ },
+ });
+ },
+
volumeSettings: function () {
let me = this;
let value = (name) => me.down(`field[name=${name}]`).getValue();
@@ -35,7 +61,13 @@ Ext.define('PVE.storage.wizard.SAN', {
storage: value('storage'),
vgname: value('vgname'),
'snapshot-as-volume-chain': value('snapshot-as-volume-chain') ? 1 : 0,
- nodes: me.connection.nodes,
+ nodes:
+ me.wizardType === 'fc'
+ ? []
+ .concat(value('nodes') || [])
+ .filter(Boolean)
+ .join(',')
+ : me.connection.nodes,
};
},
@@ -63,6 +95,7 @@ Ext.define('PVE.storage.wizard.SAN', {
Ext.create('PVE.window.SANLunState', {
wwid,
storage: values.storage,
+ fc: me.wizardType === 'fc',
autoShow: true,
});
},
@@ -70,11 +103,18 @@ Ext.define('PVE.storage.wizard.SAN', {
},
multipathSummary: function (lun) {
+ let me = this;
// an explicit entry takes precedence, also for a LUN of the connection storage
if (lun.multipath === 'manual') {
return PVE.SANUtils.multipathText('manual');
}
- return PVE.SANUtils.multipathText('storage', this.connection.storage);
+ if (me.connection) {
+ return PVE.SANUtils.multipathText('storage', me.connection.storage);
+ }
+ // the Fibre Channel setup adds an entry for a LUN without multipath
+ return lun.multipath === 'none'
+ ? gettext('Explicit entry, added by this setup')
+ : PVE.SANUtils.multipathText(lun.multipath, lun['multipath-storage']);
},
updateSummary: function () {
@@ -82,7 +122,6 @@ Ext.define('PVE.storage.wizard.SAN', {
let values = me.volumeSettings();
let lun = me.down('#luns').getSelection();
let rows = [
- [gettext('Connection Storage'), me.connection.storage],
[gettext('Storage ID'), values.storage],
[gettext('Volume Group'), values.vgname],
['WWID', lun.wwid],
@@ -94,6 +133,9 @@ Ext.define('PVE.storage.wizard.SAN', {
Proxmox.Utils.format_boolean(values['snapshot-as-volume-chain']),
],
];
+ if (me.connection) {
+ rows.unshift([gettext('Connection Storage'), me.connection.storage]);
+ }
me.down('#summary')
.getStore()
.setData(rows.map(([key, value]) => ({ key, value })));
@@ -104,11 +146,19 @@ Ext.define('PVE.storage.wizard.SAN', {
let values = me.volumeSettings();
let lun = me.down('#luns').getSelection();
me.down('#submit').disable();
- PVE.storage.wizard.createIScsiLVM(me, values, lun);
+ if (me.wizardType === 'fc') {
+ PVE.storage.wizard.createFC(me, values, lun);
+ } else {
+ PVE.storage.wizard.createIScsiLVM(me, values, lun);
+ }
},
initComponent: function () {
let me = this;
+ if (!['iscsi', 'fc'].includes(me.wizardType)) {
+ throw 'no SAN storage type specified';
+ }
+ let iscsi = me.wizardType === 'iscsi';
me.subject = PVE.storage.wizard.subject(me.wizardType);
me.title = Proxmox.Utils.dialog_title(me.subject, true, true);
let common = PVE.panel.StorageBase.commonFields(true);
@@ -130,13 +180,35 @@ Ext.define('PVE.storage.wizard.SAN', {
snapshots.hint,
],
};
+ if (!iscsi) {
+ settings.advancedItems = [
+ { ...common.nodes, validator: PVE.storage.wizard.validateNodes },
+ ];
+ }
me.items = [
- { xtype: 'pveStorageWizardIScsiTarget', title: gettext('Target'), itemId: 'target' },
+ ...(iscsi
+ ? [
+ {
+ xtype: 'pveStorageWizardIScsiTarget',
+ title: gettext('Target'),
+ itemId: 'target',
+ },
+ ]
+ : []),
{
xtype: 'pveStorageWizardLunSelect',
title: 'LUN',
itemId: 'luns',
onlineHelp: 'storage_multipath',
+ // the nodes only see a newly mapped Fibre Channel LUN after a rescan
+ rescanNote: iscsi
+ ? undefined
+ : Ext.String.format(
+ gettext(
+ 'After mapping a new LUN on the array, rescan the Fibre Channel hosts of each node (<a href="{0}" target="_blank" rel="noopener noreferrer">documentation</a>).',
+ ),
+ Ext.htmlEncode(Proxmox.Utils.get_help_link('storage_multipath')),
+ ),
},
settings,
{
@@ -171,14 +243,16 @@ Ext.define('PVE.storage.wizard.SAN', {
me.callParent();
let tabs = me.down('#wizcontent');
tabs.on('tabchange', function (tp, tab) {
- if (tab === me.down('#luns')) {
+ if (iscsi && tab === me.down('#luns')) {
me.down('#back').disable();
}
me.down('#submit').setText(
tab === me.down('#target') ? gettext('Next') : gettext('Finish'),
);
});
- me.down('#submit').setText(gettext('Next'));
+ if (iscsi) {
+ me.down('#submit').setText(gettext('Next'));
+ }
me.on('destroy', () => me.reloadCallback?.());
},
});
diff --git a/www/manager6/window/SANLunState.js b/www/manager6/window/SANLunState.js
index 154836f3b..a0a6d514d 100644
--- a/www/manager6/window/SANLunState.js
+++ b/www/manager6/window/SANLunState.js
@@ -51,9 +51,13 @@ Ext.define('PVE.window.SANLunState', {
margin: '0 0 10 0',
html: Ext.htmlEncode(
Ext.String.format(
- gettext(
- 'Storage "{0}" was added. Guests on this storage cannot run on a node that stays on "Missing": check its access to the LUN on the array.',
- ),
+ me.fc
+ ? gettext(
+ 'Storage "{0}" was added. Guests on this storage cannot run on a node that stays on "Missing": check its access to the LUN on the array and rescan its Fibre Channel hosts.',
+ )
+ : gettext(
+ 'Storage "{0}" was added. Guests on this storage cannot run on a node that stays on "Missing": check its access to the LUN on the array.',
+ ),
me.storage,
),
),
next prev parent reply other threads:[~2026-11-16 1:29 UTC|newest]
Thread overview: 38+ messages / expand[flat|nested] mbox.gz Atom feed top
2026-11-16 1:23 [PATCH v5 cluster,storage,docs,manager 00/36] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 cluster 01/36] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 02/36] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 03/36] diskmanage: qualify NVMe over fabrics transport Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 04/36] diskmanage: optionally include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 05/36] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 06/36] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 07/36] multipath: add a library around multipathd Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 08/36] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 09/36] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 10/36] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 11/36] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 12/36] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 13/36] multipath: publish per-node status Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 14/36] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 15/36] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 16/36] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 17/36] pvesm: expose the " Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 18/36] api: add node-level iSCSI status Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 19/36] disks: lvm: drop unused imports Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 20/36] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 21/36] disks: lvm: refuse to destroy the volume group of a shared storage Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 storage 22/36] disks: allow wiping a SAN LUN that no storage uses Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 docs 23/36] storage: document the cluster-wide multipath management Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 24/36] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 25/36] report: add the managed multipath configuration Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 26/36] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 27/36] api: nodes: expose the iSCSI status Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 28/36] ui: dc: add a SAN view Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 29/36] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 30/36] ui: lvm: enable shared when a base storage is selected Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 31/36] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 32/36] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 33/36] ui: node: san: show iSCSI targets and sessions Thomas Lamprecht
2026-11-16 1:23 ` [PATCH v5 manager 34/36] ui: dc: san: add a guided setup for shared LVM on iSCSI Thomas Lamprecht
2026-11-16 1:23 ` Thomas Lamprecht [this message]
2026-11-16 1:23 ` [PATCH v5 manager 36/36] ui: storage: point the iSCSI and LVM add dialogs to the SAN view Thomas Lamprecht
2026-11-18 8:11 ` superseded: [PATCH v5 cluster,storage,docs,manager 00/36] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20261116012355.3187417-36-t.lamprecht@proxmox.com \
--to=t.lamprecht@proxmox.com \
--cc=pve-devel@lists.proxmox.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox