public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
From: Thomas Lamprecht <t.lamprecht@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [PATCH v3 storage 23/76] diskmanage: collect native NVMe multipath path state
Date: Fri,  6 Nov 2026 00:30:58 +0100	[thread overview]
Message-ID: <20261105233336.2178064-24-t.lamprecht@proxmox.com> (raw)
In-Reply-To: <20261105233336.2178064-1-t.lamprecht@proxmox.com>

From: Dietmar Maurer <dietmar@proxmox.com>

NVMe over Fabrics usually uses native multipath, whose paths are
unknown to multipathd. Collect controller state and address, plus
per-path namespace ANA state, from sysfs and group them by head
namespace. This allows uniform health reporting for both multipath
stacks. Local single-controller devices have no per-path entries and
are omitted.

Signed-off-by: Dietmar Maurer <dietmar@proxmox.com>
[TL: drop redundant comments]
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
---
 src/PVE/Diskmanage.pm                         | 60 +++++++++++++++++++
 .../nvme-subsystem/nvme-subsys0/nvme3/address |  1 +
 .../nvme-subsys0/nvme3/nvme2c3n1/ana_state    |  1 +
 .../nvme-subsystem/nvme-subsys0/nvme3/state   |  1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/address |  1 +
 .../nvme-subsys0/nvme4/nvme2c4n1/ana_state    |  1 +
 .../nvme-subsystem/nvme-subsys0/nvme4/state   |  1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/address |  1 +
 .../nvme-subsystem/nvme-subsys1/nvme0/state   |  1 +
 .../multipath/nvme_path_status_expected.json  | 19 ++++++
 src/test/disklist_test.pm                     | 16 +++++
 11 files changed, 103 insertions(+)
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/address
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/nvme2c3n1/ana_state
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/state
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/address
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/nvme2c4n1/ana_state
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/state
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/address
 create mode 100644 src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/state
 create mode 100644 src/test/disk_tests/multipath/nvme_path_status_expected.json

diff --git a/src/PVE/Diskmanage.pm b/src/PVE/Diskmanage.pm
index caad0fee..a7eb2b21 100644
--- a/src/PVE/Diskmanage.pm
+++ b/src/PVE/Diskmanage.pm
@@ -974,6 +974,66 @@ sub is_multipath_device {
     return $uuid =~ m/^(?:part\d+-)?mpath-/ ? 1 : 0;
 }
 
+# Native multipath creates per-path namespace children nvmeXcYnZ below controllers. Local
+# single-controller devices lack these children and are omitted.
+sub get_nvme_path_status {
+    my $res = {};
+
+    dir_glob_foreach(
+        '/sys/class/nvme-subsystem',
+        'nvme-subsys\d+',
+        sub {
+            my ($subsys) = @_;
+            my $subsysdir = "/sys/class/nvme-subsystem/$subsys";
+
+            dir_glob_foreach(
+                $subsysdir,
+                'nvme\d+',
+                sub {
+                    my ($ctrl) = @_;
+                    my $ctrldir = "$subsysdir/$ctrl";
+                    my $state = file_read_firstline("$ctrldir/state") // return;
+                    my $address = file_read_firstline("$ctrldir/address");
+
+                    dir_glob_foreach(
+                        $ctrldir,
+                        'nvme\d+c\d+n\d+',
+                        sub {
+                            my ($pathdev) = @_;
+                            return if $pathdev !~ m/^nvme(\d+)c\d+n(\d+)$/;
+                            my $head = "nvme$1n$2";
+
+                            my $entry = { device => "/dev/$ctrl", state => $state };
+                            $entry->{address} = $address
+                                if defined($address) && $address ne '';
+                            my $ana = file_read_firstline("$ctrldir/$pathdev/ana_state");
+                            $entry->{'ana-state'} = $ana if defined($ana);
+
+                            # 'change' is transient; paths in 'inaccessible' or 'persistent-loss'
+                            # cannot serve IO even on a live controller
+                            my $usable = $state eq 'live'
+                                && (!defined($ana)
+                                    || $ana eq 'optimized'
+                                    || $ana eq 'non-optimized');
+
+                            my $status = $res->{$head} //= { active => 0, paths => [] };
+                            $status->{active}++ if $usable;
+                            push @{ $status->{paths} }, $entry;
+                        },
+                    );
+                },
+            );
+        },
+    );
+
+    for my $status (values %$res) {
+        @{ $status->{paths} } =
+            sort { $a->{device} cmp $b->{device} } @{ $status->{paths} };
+    }
+
+    return $res;
+}
+
 sub lookup_multipath_map {
     my ($devpath) = @_;
 
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/address b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/address
new file mode 100644
index 00000000..803fab3e
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/address
@@ -0,0 +1 @@
+traddr=192.168.3.209,trsvcid=4420,src_addr=192.168.2.171
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/nvme2c3n1/ana_state b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/nvme2c3n1/ana_state
new file mode 100644
index 00000000..e48c58f5
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/nvme2c3n1/ana_state
@@ -0,0 +1 @@
+optimized
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/state b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/state
new file mode 100644
index 00000000..e23fe645
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme3/state
@@ -0,0 +1 @@
+live
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/address b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/address
new file mode 100644
index 00000000..36618744
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/address
@@ -0,0 +1 @@
+traddr=192.168.3.109,trsvcid=4420,src_addr=192.168.2.171
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/nvme2c4n1/ana_state b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/nvme2c4n1/ana_state
new file mode 100644
index 00000000..436c48ee
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/nvme2c4n1/ana_state
@@ -0,0 +1 @@
+inaccessible
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/state b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/state
new file mode 100644
index 00000000..e23fe645
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys0/nvme4/state
@@ -0,0 +1 @@
+live
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/address b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/address
new file mode 100644
index 00000000..f99fcb14
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/address
@@ -0,0 +1 @@
+0000:02:00.0
diff --git a/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/state b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/state
new file mode 100644
index 00000000..e23fe645
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme-subsystem/nvme-subsys1/nvme0/state
@@ -0,0 +1 @@
+live
diff --git a/src/test/disk_tests/multipath/nvme_path_status_expected.json b/src/test/disk_tests/multipath/nvme_path_status_expected.json
new file mode 100644
index 00000000..62611b3f
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme_path_status_expected.json
@@ -0,0 +1,19 @@
+{
+    "nvme2n1": {
+        "active": 1,
+        "paths": [
+            {
+                "device": "/dev/nvme3",
+                "state": "live",
+                "address": "traddr=192.168.3.209,trsvcid=4420,src_addr=192.168.2.171",
+                "ana-state": "optimized"
+            },
+            {
+                "device": "/dev/nvme4",
+                "state": "live",
+                "address": "traddr=192.168.3.109,trsvcid=4420,src_addr=192.168.2.171",
+                "ana-state": "inaccessible"
+            }
+        ]
+    }
+}
diff --git a/src/test/disklist_test.pm b/src/test/disklist_test.pm
index 21823daa..c6fb620c 100644
--- a/src/test/disklist_test.pm
+++ b/src/test/disklist_test.pm
@@ -111,6 +111,7 @@ sub mocked_file_read_firstline {
     my $originalsub = $diskmanage_module->original('file_read_firstline');
 
     $path =~ s|^/sys/block|disk_tests/$testcasedir|;
+    $path =~ s|^/sys/class/nvme-subsystem|disk_tests/$testcasedir/nvme-subsystem|;
 
     return &$originalsub($path);
 }
@@ -120,6 +121,12 @@ sub mocked_dir_glob_foreach {
 
     my $lines = [];
 
+    # nvme subsystem trees are provided as directories, glob them like production code
+    if ($dir =~ s|^/sys/class/nvme-subsystem|disk_tests/$testcasedir/nvme-subsystem|) {
+        my $originalsub = $diskmanage_module->original('dir_glob_foreach');
+        return &$originalsub($dir, $regex, $sub);
+    }
+
     # read lines in from file
     if ($dir =~ m{^/sys/block$}) {
         @$lines = split(/\n/, read_test_file('disklist'));
@@ -267,6 +274,15 @@ sub test_disk_list {
             is($@, '', 'the SAN opt-in accepts an unused iSCSI LUN');
         }
 
+        if (-f "disk_tests/$testcasedir/nvme_path_status_expected.json") {
+            my $status = PVE::Diskmanage::get_nvme_path_status();
+            my $expected_status = decode_json(read_test_file('nvme_path_status_expected.json'));
+
+            print Dumper($status) if $print;
+            $testcount++;
+            is_deeply($status, $expected_status, 'nvme path status should be the same');
+        }
+
         done_testing($testcount);
     };
 }
-- 
2.47.3




  parent reply	other threads:[~2026-11-06  0:52 UTC|newest]

Thread overview: 77+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-11-05 23:30 [PATCH v3 proxmox,proxmox-perl-rs,cluster,storage,docs,manager 00/76] SAN: cluster-wide multipath, SAN views and a guided storage setup Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 proxmox 01/76] add proxmox-multipath crate Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 proxmox-perl-rs 02/76] pve-rs: add PVE::RS::Multipath bindings for multipathd status parsing Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 cluster 03/76] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 04/76] storage: distinguish status-only activation in plugins Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 05/76] lvm: find a shared volume group created by another node Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 06/76] storage: bound LVM status commands Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 07/76] iscsi: rate-limit session rescans per target Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 08/76] iscsi: list the LUNs of each session, not of its SCSI host Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 09/76] lvm: refuse to create a volume group on a device that holds data Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 10/76] lvm: refuse a base volume of a target that serves disk images Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 11/76] iscsi: refuse virtual devices other than multipath maps as volumes Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 12/76] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 13/76] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 14/76] diskmanage: qualify NVMe over fabrics transport Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 15/76] disks: list: add include-remote parameter Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 16/76] diskmanage: include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 17/76] diskmanage: link multipath member disks to their map device Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 18/76] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 19/76] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 20/76] pvesm: expose the " Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 21/76] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 22/76] multipath: add a library around multipathd Thomas Lamprecht
2026-11-05 23:30 ` Thomas Lamprecht [this message]
2026-11-05 23:30 ` [PATCH v3 storage 24/76] api: scan: san-luns: report path state Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 25/76] diskmanage: collect local block device users Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 26/76] api: add node-level iSCSI status and maintenance Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 27/76] api: iscsi: add session logout with last-path protection Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 28/76] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 29/76] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 30/76] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 31/76] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 32/76] iscsi: share the initiator identity reader Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 33/76] multipath: publish per-node status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 34/76] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 35/76] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 36/76] multipath: collect identities of non-iSCSI SCSI paths Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 37/76] api: scan: san-luns: report the multipath state of each LUN Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 38/76] api: scan: flag duplicate physical volumes on distinct LUNs Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 39/76] api: disks: recheck local users and retain wipe device references Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 40/76] iscsi: name plain LUNs after their identity link Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 41/76] api: disks: guard SAN wipes with stable identities and storage checks Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 42/76] api: scan: refresh SAN usage with bounded probes Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 docs 43/76] storage: lvm: note the rescan after extending a shared volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 docs 44/76] storage: document the cluster-wide multipath management Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 45/76] api: ceph: osd: keep iSCSI LUNs out of OSD creation Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 46/76] pvestatd: track pending storage status commands across re-exec Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 47/76] ui: storage: factor out the scan picker error mask Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 48/76] ui: storage: nfs: show scan errors and empty results Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 49/76] ui: storage: allow changing the node for NFS/CIFS scans Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 50/76] ui: storage: add guided remote storage wizard with NFS support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 51/76] ui: storage wizard: add SMB/CIFS support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 52/76] ui: storage wizard: preserve settings after partial setup Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 53/76] ui: storage wizard: add Fibre Channel shared LVM setup Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 54/76] ui: storage wizard: reconcile unanswered storage creation Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 55/76] ui: storage wizard: add ZFS over iSCSI support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 56/76] ui: dc: storage: add remote storage wizard entry to the add menu Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 57/76] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 58/76] ui: san luns: show multipath path state Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 59/76] api: nodes: expose iSCSI status and maintenance Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 60/76] pvenode: add iscsi commands Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 61/76] ui: node: san: add iSCSI target and session management Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 62/76] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 63/76] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 64/76] ui: dc: add a cluster-wide multipath view Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 65/76] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 66/76] ui: san luns: show multipath state and manage LUN entries Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 67/76] ui: storage wizard: add iSCSI support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 68/76] ui: storage wizard: iscsi: show cluster initiator names Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 69/76] ui: storage wizard: iscsi: enable multipath for shared LVM Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 70/76] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 71/76] ui: storage wizard: iscsi: reuse existing target connections Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 72/76] ui: storage wizard: fibre channel: enable multipath for a LUN Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 73/76] ui: storage wizard: let root@pam wipe a LUN with data Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 74/76] ui: storage wizard: do not offer LUNs in use for a new volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 75/76] ui: san: show the local users of a LUN in its usage tooltip Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 76/76] ui: san: check the other nodes for users before wiping a LUN Thomas Lamprecht

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20261105233336.2178064-24-t.lamprecht@proxmox.com \
    --to=t.lamprecht@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal