public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
From: Thomas Lamprecht <t.lamprecht@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [PATCH v3 storage 14/76] diskmanage: qualify NVMe over fabrics transport
Date: Fri,  6 Nov 2026 00:30:49 +0100	[thread overview]
Message-ID: <20261105233336.2178064-15-t.lamprecht@proxmox.com> (raw)
In-Reply-To: <20261105233336.2178064-1-t.lamprecht@proxmox.com>

From: Dietmar Maurer <dietmar@proxmox.com>

lsblk reports 'nvme' for fabrics-attached namespaces, preventing clients
from distinguishing them from local PCIe drives. Read the transport from
the controller, or a subsystem controller for native multipath, and
report nvme-fc, nvme-tcp, nvme-rdma, or nvme-loop instead.

This lets SAN scans and local storage dialogs select suitable devices
without hiding fabrics-attached namespaces server-side.

Signed-off-by: Dietmar Maurer <dietmar@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
---
 src/PVE/Diskmanage.pm                         | 27 +++++++++++++++
 src/test/disk_tests/multipath/disklist        |  2 ++
 .../multipath/disklist_expected.json          | 33 +++++++++++++++++++
 src/test/disk_tests/multipath/lsblk           | 14 ++++++++
 .../disk_tests/multipath/nvme8n1/device/model |  1 +
 .../multipath/nvme8n1/device/transport        |  1 +
 .../multipath/nvme8n1/queue/rotational        |  1 +
 src/test/disk_tests/multipath/nvme8n1/size    |  1 +
 src/test/disk_tests/multipath/nvme8n1_udevadm | 14 ++++++++
 .../disk_tests/multipath/nvme9n1/device/model |  1 +
 .../multipath/nvme9n1/device/transport        |  1 +
 .../multipath/nvme9n1/device/vendor           |  1 +
 .../multipath/nvme9n1/queue/rotational        |  1 +
 src/test/disk_tests/multipath/nvme9n1/size    |  1 +
 src/test/disk_tests/multipath/nvme9n1_udevadm | 12 +++++++
 15 files changed, 111 insertions(+)
 create mode 100644 src/test/disk_tests/multipath/nvme8n1/device/model
 create mode 100644 src/test/disk_tests/multipath/nvme8n1/device/transport
 create mode 100644 src/test/disk_tests/multipath/nvme8n1/queue/rotational
 create mode 100644 src/test/disk_tests/multipath/nvme8n1/size
 create mode 100644 src/test/disk_tests/multipath/nvme8n1_udevadm
 create mode 100644 src/test/disk_tests/multipath/nvme9n1/device/model
 create mode 100644 src/test/disk_tests/multipath/nvme9n1/device/transport
 create mode 100644 src/test/disk_tests/multipath/nvme9n1/device/vendor
 create mode 100644 src/test/disk_tests/multipath/nvme9n1/queue/rotational
 create mode 100644 src/test/disk_tests/multipath/nvme9n1/size
 create mode 100644 src/test/disk_tests/multipath/nvme9n1_udevadm

diff --git a/src/PVE/Diskmanage.pm b/src/PVE/Diskmanage.pm
index e950b6dd..bc81e854 100644
--- a/src/PVE/Diskmanage.pm
+++ b/src/PVE/Diskmanage.pm
@@ -503,6 +503,26 @@ sub is_iscsi {
     return 0;
 }
 
+# Returns the NVMe transport (pcie, fc, tcp, rdma, loop) of a namespace, either directly from
+# its controller, or from any controller of its subsystem for native NVMe multipath setups.
+sub get_nvme_transport {
+    my ($sysdir) = @_;
+
+    my $transport = file_read_firstline("$sysdir/device/transport");
+    return $transport if defined($transport);
+
+    dir_glob_foreach(
+        "$sysdir/device",
+        'nvme\d+',
+        sub {
+            my ($controller) = @_;
+            $transport //= file_read_firstline("$sysdir/device/$controller/transport");
+        },
+    );
+
+    return $transport;
+}
+
 my sub is_ssdlike {
     my ($type) = @_;
     return $type eq 'ssd' || $type eq 'nvme';
@@ -595,6 +615,9 @@ sub get_disks {
             # we do not want iscsi devices
             return if is_iscsi($sysdir);
 
+            my $nvme_transport;
+            $nvme_transport = get_nvme_transport($sysdir) if $dev =~ m/^nvme/;
+
             my $sysdata = get_sysdir_info($sysdir);
             return if !defined($sysdata);
 
@@ -646,7 +669,11 @@ sub get_disks {
                 wearout => $wearout,
             };
 
+            # lsblk reports plain 'nvme' for fabrics attached namespaces
             my $transport = $lsblk_info->{$devpath}->{tran};
+            if (defined($nvme_transport) && $nvme_transport ne 'pcie') {
+                $transport = "nvme-$nvme_transport";
+            }
             $disklist->{$dev}->{transport} = $transport if defined($transport);
             $disklist->{$dev}->{mounted} = 1 if exists $mounted->{$devpath};
 
diff --git a/src/test/disk_tests/multipath/disklist b/src/test/disk_tests/multipath/disklist
index 92935894..f759ba9e 100644
--- a/src/test/disk_tests/multipath/disklist
+++ b/src/test/disk_tests/multipath/disklist
@@ -7,3 +7,5 @@ dm-1
 dm-2
 dm-3
 dm-4
+nvme8n1
+nvme9n1
diff --git a/src/test/disk_tests/multipath/disklist_expected.json b/src/test/disk_tests/multipath/disklist_expected.json
index a8e74fa1..ec442969 100644
--- a/src/test/disk_tests/multipath/disklist_expected.json
+++ b/src/test/disk_tests/multipath/disklist_expected.json
@@ -70,5 +70,38 @@
         "by_id_link": "/dev/disk/by-id/scsi-36001405000000000000000000000000d",
         "transport": "fc",
         "used": "Device Mapper"
+    },
+    "nvme8n1": {
+        "devpath": "/dev/nvme8n1",
+        "size": 10737418240,
+        "vendor": "unknown",
+        "model": "FCMODEL",
+        "serial": "FCNVME1",
+        "wwn": "uuid.20000000-0000-0000-0000-000000000001",
+        "gpt": 0,
+        "rpm": 0,
+        "type": "nvme",
+        "health": "UNKNOWN",
+        "wearout": "N/A",
+        "osdid": -1,
+        "osdid-list": null,
+        "by_id_link": "/dev/disk/by-id/nvme-FCMODEL_FCNVME1",
+        "transport": "nvme-fc"
+    },
+    "nvme9n1": {
+        "devpath": "/dev/nvme9n1",
+        "size": 10737418240,
+        "vendor": "FABVEND",
+        "model": "FABRICS CTRL",
+        "serial": "FAB1",
+        "wwn": "uuid.10000000-0000-0000-0000-000000000001",
+        "gpt": 0,
+        "rpm": 0,
+        "type": "nvme",
+        "health": "UNKNOWN",
+        "wearout": "N/A",
+        "osdid": -1,
+        "osdid-list": null,
+        "transport": "nvme-tcp"
     }
 }
diff --git a/src/test/disk_tests/multipath/lsblk b/src/test/disk_tests/multipath/lsblk
index 91f74574..dfc1ae1a 100644
--- a/src/test/disk_tests/multipath/lsblk
+++ b/src/test/disk_tests/multipath/lsblk
@@ -58,6 +58,20 @@
          "fstype": null,
          "tran": null,
          "pttype": null
+      },
+      {
+         "path": "/dev/nvme8n1",
+         "parttype": null,
+         "fstype": null,
+         "tran": "nvme",
+         "pttype": null
+      },
+      {
+         "path": "/dev/nvme9n1",
+         "parttype": null,
+         "fstype": null,
+         "tran": "nvme",
+         "pttype": null
       }
    ]
 }
diff --git a/src/test/disk_tests/multipath/nvme8n1/device/model b/src/test/disk_tests/multipath/nvme8n1/device/model
new file mode 100644
index 00000000..1aac689e
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme8n1/device/model
@@ -0,0 +1 @@
+FCMODEL
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme8n1/device/transport b/src/test/disk_tests/multipath/nvme8n1/device/transport
new file mode 100644
index 00000000..8b517d01
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme8n1/device/transport
@@ -0,0 +1 @@
+fc
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme8n1/queue/rotational b/src/test/disk_tests/multipath/nvme8n1/queue/rotational
new file mode 100644
index 00000000..c2270834
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme8n1/queue/rotational
@@ -0,0 +1 @@
+0
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme8n1/size b/src/test/disk_tests/multipath/nvme8n1/size
new file mode 100644
index 00000000..8280959b
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme8n1/size
@@ -0,0 +1 @@
+20971520
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme8n1_udevadm b/src/test/disk_tests/multipath/nvme8n1_udevadm
new file mode 100644
index 00000000..d0cd5ea9
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme8n1_udevadm
@@ -0,0 +1,14 @@
+P: /devices/virtual/nvme-subsystem/nvme-subsys8/nvme8n1
+N: nvme8n1
+S: disk/by-id/nvme-FCMODEL_FCNVME1
+E: DEVLINKS=/dev/disk/by-id/nvme-FCMODEL_FCNVME1
+E: DEVNAME=/dev/nvme8n1
+E: DEVPATH=/devices/virtual/nvme-subsystem/nvme-subsys8/nvme8n1
+E: DEVTYPE=disk
+E: ID_MODEL=FCMODEL
+E: ID_SERIAL=FCNVME_1
+E: ID_SERIAL_SHORT=FCNVME1
+E: ID_WWN=uuid.20000000-0000-0000-0000-000000000001
+E: MAJOR=259
+E: MINOR=1
+E: SUBSYSTEM=block
diff --git a/src/test/disk_tests/multipath/nvme9n1/device/model b/src/test/disk_tests/multipath/nvme9n1/device/model
new file mode 100644
index 00000000..aa0287c7
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1/device/model
@@ -0,0 +1 @@
+FABMODEL
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme9n1/device/transport b/src/test/disk_tests/multipath/nvme9n1/device/transport
new file mode 100644
index 00000000..f5483dbf
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1/device/transport
@@ -0,0 +1 @@
+tcp
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme9n1/device/vendor b/src/test/disk_tests/multipath/nvme9n1/device/vendor
new file mode 100644
index 00000000..cdc6ddfa
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1/device/vendor
@@ -0,0 +1 @@
+FABVEND
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme9n1/queue/rotational b/src/test/disk_tests/multipath/nvme9n1/queue/rotational
new file mode 100644
index 00000000..c2270834
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1/queue/rotational
@@ -0,0 +1 @@
+0
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme9n1/size b/src/test/disk_tests/multipath/nvme9n1/size
new file mode 100644
index 00000000..8280959b
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1/size
@@ -0,0 +1 @@
+20971520
\ No newline at end of file
diff --git a/src/test/disk_tests/multipath/nvme9n1_udevadm b/src/test/disk_tests/multipath/nvme9n1_udevadm
new file mode 100644
index 00000000..b6d13ccb
--- /dev/null
+++ b/src/test/disk_tests/multipath/nvme9n1_udevadm
@@ -0,0 +1,12 @@
+P: /devices/virtual/nvme-subsystem/nvme-subsys9/nvme9n1
+N: nvme9n1
+E: DEVNAME=/dev/nvme9n1
+E: DEVPATH=/devices/virtual/nvme-subsystem/nvme-subsys9/nvme9n1
+E: DEVTYPE=disk
+E: ID_MODEL=FABRICS CTRL
+E: ID_SERIAL=FABRICS_1
+E: ID_SERIAL_SHORT=FAB1
+E: ID_WWN=uuid.10000000-0000-0000-0000-000000000001
+E: MAJOR=259
+E: MINOR=0
+E: SUBSYSTEM=block
-- 
2.47.3




  parent reply	other threads:[~2026-11-06  0:51 UTC|newest]

Thread overview: 77+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-11-05 23:30 [PATCH v3 proxmox,proxmox-perl-rs,cluster,storage,docs,manager 00/76] SAN: cluster-wide multipath, SAN views and a guided storage setup Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 proxmox 01/76] add proxmox-multipath crate Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 proxmox-perl-rs 02/76] pve-rs: add PVE::RS::Multipath bindings for multipathd status parsing Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 cluster 03/76] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 04/76] storage: distinguish status-only activation in plugins Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 05/76] lvm: find a shared volume group created by another node Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 06/76] storage: bound LVM status commands Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 07/76] iscsi: rate-limit session rescans per target Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 08/76] iscsi: list the LUNs of each session, not of its SCSI host Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 09/76] lvm: refuse to create a volume group on a device that holds data Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 10/76] lvm: refuse a base volume of a target that serves disk images Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 11/76] iscsi: refuse virtual devices other than multipath maps as volumes Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 12/76] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 13/76] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-05 23:30 ` Thomas Lamprecht [this message]
2026-11-05 23:30 ` [PATCH v3 storage 15/76] disks: list: add include-remote parameter Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 16/76] diskmanage: include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 17/76] diskmanage: link multipath member disks to their map device Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 18/76] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 19/76] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 20/76] pvesm: expose the " Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 21/76] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 22/76] multipath: add a library around multipathd Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 23/76] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-05 23:30 ` [PATCH v3 storage 24/76] api: scan: san-luns: report " Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 25/76] diskmanage: collect local block device users Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 26/76] api: add node-level iSCSI status and maintenance Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 27/76] api: iscsi: add session logout with last-path protection Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 28/76] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 29/76] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 30/76] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 31/76] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 32/76] iscsi: share the initiator identity reader Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 33/76] multipath: publish per-node status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 34/76] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 35/76] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 36/76] multipath: collect identities of non-iSCSI SCSI paths Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 37/76] api: scan: san-luns: report the multipath state of each LUN Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 38/76] api: scan: flag duplicate physical volumes on distinct LUNs Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 39/76] api: disks: recheck local users and retain wipe device references Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 40/76] iscsi: name plain LUNs after their identity link Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 41/76] api: disks: guard SAN wipes with stable identities and storage checks Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 storage 42/76] api: scan: refresh SAN usage with bounded probes Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 docs 43/76] storage: lvm: note the rescan after extending a shared volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 docs 44/76] storage: document the cluster-wide multipath management Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 45/76] api: ceph: osd: keep iSCSI LUNs out of OSD creation Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 46/76] pvestatd: track pending storage status commands across re-exec Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 47/76] ui: storage: factor out the scan picker error mask Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 48/76] ui: storage: nfs: show scan errors and empty results Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 49/76] ui: storage: allow changing the node for NFS/CIFS scans Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 50/76] ui: storage: add guided remote storage wizard with NFS support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 51/76] ui: storage wizard: add SMB/CIFS support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 52/76] ui: storage wizard: preserve settings after partial setup Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 53/76] ui: storage wizard: add Fibre Channel shared LVM setup Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 54/76] ui: storage wizard: reconcile unanswered storage creation Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 55/76] ui: storage wizard: add ZFS over iSCSI support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 56/76] ui: dc: storage: add remote storage wizard entry to the add menu Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 57/76] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 58/76] ui: san luns: show multipath path state Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 59/76] api: nodes: expose iSCSI status and maintenance Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 60/76] pvenode: add iscsi commands Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 61/76] ui: node: san: add iSCSI target and session management Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 62/76] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 63/76] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 64/76] ui: dc: add a cluster-wide multipath view Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 65/76] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 66/76] ui: san luns: show multipath state and manage LUN entries Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 67/76] ui: storage wizard: add iSCSI support Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 68/76] ui: storage wizard: iscsi: show cluster initiator names Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 69/76] ui: storage wizard: iscsi: enable multipath for shared LVM Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 70/76] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 71/76] ui: storage wizard: iscsi: reuse existing target connections Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 72/76] ui: storage wizard: fibre channel: enable multipath for a LUN Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 73/76] ui: storage wizard: let root@pam wipe a LUN with data Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 74/76] ui: storage wizard: do not offer LUNs in use for a new volume group Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 75/76] ui: san: show the local users of a LUN in its usage tooltip Thomas Lamprecht
2026-11-05 23:31 ` [PATCH v3 manager 76/76] ui: san: check the other nodes for users before wiping a LUN Thomas Lamprecht

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20261105233336.2178064-15-t.lamprecht@proxmox.com \
    --to=t.lamprecht@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal