public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
* [PATCH qemu-server v7 0/2] hotplug: improve and fix cleanup/error handling
@ 2026-11-05  8:22 Dominik Csapak
  2026-11-05  8:22 ` [PATCH qemu-server v7 1/2] hotplug: factor out cleanup of disk devices Dominik Csapak
  2026-11-05  8:22 ` [PATCH qemu-server v7 2/2] hotplug: clean up disk devices/objects if adding them failed Dominik Csapak
  0 siblings, 2 replies; 3+ messages in thread
From: Dominik Csapak @ 2026-11-05  8:22 UTC (permalink / raw)
  To: pve-devel

This replaces my earlier v4 9/9 patch[0]

It uses a different approach now by unifying the cleanup and removal of
disks and their controllers.

changes from v6:
* call print_drivedevice_full before adding the SCSI controller, so a
  volume rejected by the storage layer (e.g. a vanished storage) does
  not cause a controller plug/unplug cycle, and add a test for it
* add a test for a failed disk hotplug on a shared SCSI controller,
  which must keep the controller for the remaining disks

changes from v5:
* rebase on master
* rename helper to 'delete_disk_hardware'
* don't eval the individual calls, but always the whole function
  (drops noerr parameter)

changes from v4:
* rebase on master
* new bugfix (1/4)
* new patch for iothread deletion
* new patch for refactoring the cleanup

0: https://lore.proxmox.com/pve-devel/20261023130324.451252-10-d.csapak@proxmox.com/

Dominik Csapak (2):
  hotplug: factor out cleanup of disk devices
  hotplug: clean up disk devices/objects if adding them failed

 src/PVE/QemuServer.pm                         | 75 ++++++++++++-------
 src/test/hotplug/disk-add-fail.conf           | 19 +++++
 src/test/hotplug/disk-add-fail.conf.expected  | 10 +++
 src/test/hotplug/disk-add-fail2.conf          | 17 +++++
 src/test/hotplug/disk-add-fail2.conf.expected |  1 +
 .../disk-add-scsi-shared-controller-fail.conf | 19 +++++
 ...-scsi-shared-controller-fail.conf.expected |  8 ++
 .../disk-add-scsi-single-disk-fail.conf       | 19 +++++
 ...sk-add-scsi-single-disk-fail.conf.expected | 12 +++
 .../hotplug/disk-add-scsi-single-fail.conf    | 19 +++++
 .../disk-add-scsi-single-fail.conf.expected   |  5 ++
 11 files changed, 175 insertions(+), 29 deletions(-)
 create mode 100644 src/test/hotplug/disk-add-fail.conf
 create mode 100644 src/test/hotplug/disk-add-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-add-fail2.conf
 create mode 100644 src/test/hotplug/disk-add-fail2.conf.expected
 create mode 100644 src/test/hotplug/disk-add-scsi-shared-controller-fail.conf
 create mode 100644 src/test/hotplug/disk-add-scsi-shared-controller-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-add-scsi-single-disk-fail.conf
 create mode 100644 src/test/hotplug/disk-add-scsi-single-disk-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-add-scsi-single-fail.conf
 create mode 100644 src/test/hotplug/disk-add-scsi-single-fail.conf.expected

-- 
2.47.3





^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2026-11-05  8:25 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-11-05  8:22 [PATCH qemu-server v7 0/2] hotplug: improve and fix cleanup/error handling Dominik Csapak
2026-11-05  8:22 ` [PATCH qemu-server v7 1/2] hotplug: factor out cleanup of disk devices Dominik Csapak
2026-11-05  8:22 ` [PATCH qemu-server v7 2/2] hotplug: clean up disk devices/objects if adding them failed Dominik Csapak

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal