* [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf
@ 2026-06-09 12:11 Dominik Csapak
2026-06-09 14:48 ` Fiona Ebner
2026-06-10 13:43 ` superseded: " Dominik Csapak
0 siblings, 2 replies; 5+ messages in thread
From: Dominik Csapak @ 2026-06-09 12:11 UTC (permalink / raw)
To: pve-devel
OVMF can only use PXE/network boot when a virtual RNG device is added
for VMs, but this is not obvious from the UI or the error behavior.
Add a small warning to the boot order edit that says what is necessary.
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
---
changes from v1:
* removed stray debug log statement..., sry for the noise
www/manager6/qemu/BootOrderEdit.js | 22 ++++++++++++++++++++++
1 file changed, 22 insertions(+)
diff --git a/www/manager6/qemu/BootOrderEdit.js b/www/manager6/qemu/BootOrderEdit.js
index 521a3d6e..6ae1f506 100644
--- a/www/manager6/qemu/BootOrderEdit.js
+++ b/www/manager6/qemu/BootOrderEdit.js
@@ -26,6 +26,7 @@ Ext.define('PVE.qemu.BootOrderPanel', {
let grid = me.lookup('grid');
let marker = me.lookup('marker');
let emptyWarning = me.lookup('emptyWarning');
+ let rngPxeWarning = me.lookup('rngPxeWarning');
marker.originalValue = undefined;
@@ -43,6 +44,18 @@ Ext.define('PVE.qemu.BootOrderPanel', {
view.inUpdate = false;
marker.checkDirty();
emptyWarning.setHidden(val !== '');
+
+ let showRngPxeWarning = false;
+ if (
+ view.vmconfig?.bios?.toLowerCase().includes('ovmf') &&
+ !view.vmconfig?.rng0 &&
+ val?.includes('net')
+ ) {
+ showRngPxeWarning = true;
+ }
+
+ rngPxeWarning.setHidden(!showRngPxeWarning);
+
grid.getView().refresh();
},
},
@@ -238,6 +251,15 @@ Ext.define('PVE.qemu.BootOrderPanel', {
userCls: 'pmx-hint',
value: gettext('Warning: No devices selected, the VM will probably not boot!'),
},
+ {
+ xtype: 'displayfield',
+ reference: 'rngPxeWarning',
+ userCls: 'pmx-hint',
+ hidden: true,
+ value: gettext(
+ 'Warning: PXE boot with OVMF only works when a Virtio RNG device is added!',
+ ),
+ },
{
// for dirty marking and 'reset' function
xtype: 'field',
--
2.47.3
^ permalink raw reply related [flat|nested] 5+ messages in thread
* Re: [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf
2026-06-09 12:11 [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf Dominik Csapak
@ 2026-06-09 14:48 ` Fiona Ebner
2026-06-10 13:43 ` superseded: " Dominik Csapak
1 sibling, 0 replies; 5+ messages in thread
From: Fiona Ebner @ 2026-06-09 14:48 UTC (permalink / raw)
To: Dominik Csapak, pve-devel
Am 09.06.26 um 2:11 PM schrieb Dominik Csapak:
> OVMF can only use PXE/network boot when a virtual RNG device is added
> for VMs, but this is not obvious from the UI or the error behavior.
>
> Add a small warning to the boot order edit that says what is necessary.
>
> Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
Reviewed-by: Fiona Ebner <f.ebner@proxmox.com>
with some optional nits below:
> ---
> changes from v1:
> * removed stray debug log statement..., sry for the noise
>
> www/manager6/qemu/BootOrderEdit.js | 22 ++++++++++++++++++++++
> 1 file changed, 22 insertions(+)
>
> diff --git a/www/manager6/qemu/BootOrderEdit.js b/www/manager6/qemu/BootOrderEdit.js
> index 521a3d6e..6ae1f506 100644
> --- a/www/manager6/qemu/BootOrderEdit.js
> +++ b/www/manager6/qemu/BootOrderEdit.js
> @@ -26,6 +26,7 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> let grid = me.lookup('grid');
> let marker = me.lookup('marker');
> let emptyWarning = me.lookup('emptyWarning');
> + let rngPxeWarning = me.lookup('rngPxeWarning');
>
> marker.originalValue = undefined;
>
> @@ -43,6 +44,18 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> view.inUpdate = false;
> marker.checkDirty();
> emptyWarning.setHidden(val !== '');
> +
> + let showRngPxeWarning = false;
> + if (
Style nit: no need for the if block. You can assign the expression directly.
> + view.vmconfig?.bios?.toLowerCase().includes('ovmf') &&
Nit: No need for toLowerCase() and includes(), it can just be === 'ovmf'
like we already do in other places?
> + !view.vmconfig?.rng0 &&
> + val?.includes('net')
> + ) {
> + showRngPxeWarning = true;
> + }
> +
> + rngPxeWarning.setHidden(!showRngPxeWarning);
> +
> grid.getView().refresh();
> },
> },
> @@ -238,6 +251,15 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> userCls: 'pmx-hint',
> value: gettext('Warning: No devices selected, the VM will probably not boot!'),
> },
> + {
> + xtype: 'displayfield',
> + reference: 'rngPxeWarning',
> + userCls: 'pmx-hint',
> + hidden: true,
> + value: gettext(
> + 'Warning: PXE boot with OVMF only works when a Virtio RNG device is added!',
Nit: maybe use active voice?
For PXE boot with OVMF, you must add a VirtIO RNG device!
> + ),
> + },
> {
> // for dirty marking and 'reset' function
> xtype: 'field',
^ permalink raw reply [flat|nested] 5+ messages in thread
* [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf
@ 2026-06-10 13:40 Dominik Csapak
2026-06-10 13:43 ` Dominik Csapak
0 siblings, 1 reply; 5+ messages in thread
From: Dominik Csapak @ 2026-06-10 13:40 UTC (permalink / raw)
To: pve-devel
OVMF can only use PXE/network boot when a virtual RNG device is added
for VMs, but this is not obvious from the UI or the error behavior.
Add a small warning to the boot order edit that says what is necessary.
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
Reviewed-by: Fiona Ebner <f.ebner@proxmox.com>
---
changes from v1:
* incorporated fionas feedback (thanks!)
* include r-b trailer from fiona
www/manager6/qemu/BootOrderEdit.js | 16 ++++++++++++++++
1 file changed, 16 insertions(+)
diff --git a/www/manager6/qemu/BootOrderEdit.js b/www/manager6/qemu/BootOrderEdit.js
index 521a3d6e..08e71913 100644
--- a/www/manager6/qemu/BootOrderEdit.js
+++ b/www/manager6/qemu/BootOrderEdit.js
@@ -26,6 +26,7 @@ Ext.define('PVE.qemu.BootOrderPanel', {
let grid = me.lookup('grid');
let marker = me.lookup('marker');
let emptyWarning = me.lookup('emptyWarning');
+ let rngPxeWarning = me.lookup('rngPxeWarning');
marker.originalValue = undefined;
@@ -43,6 +44,14 @@ Ext.define('PVE.qemu.BootOrderPanel', {
view.inUpdate = false;
marker.checkDirty();
emptyWarning.setHidden(val !== '');
+
+ let showRngPxeWarning =
+ view.vmconfig?.bios === 'ovmf' &&
+ !view.vmconfig?.rng0 &&
+ val?.includes('net');
+
+ rngPxeWarning.setHidden(!showRngPxeWarning);
+
grid.getView().refresh();
},
},
@@ -238,6 +247,13 @@ Ext.define('PVE.qemu.BootOrderPanel', {
userCls: 'pmx-hint',
value: gettext('Warning: No devices selected, the VM will probably not boot!'),
},
+ {
+ xtype: 'displayfield',
+ reference: 'rngPxeWarning',
+ userCls: 'pmx-hint',
+ hidden: true,
+ value: gettext('Warning: For PXE boot with OVMF, you must add a VirtIO RNG device!'),
+ },
{
// for dirty marking and 'reset' function
xtype: 'field',
--
2.47.3
^ permalink raw reply related [flat|nested] 5+ messages in thread
* Re: [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf
2026-06-10 13:40 Dominik Csapak
@ 2026-06-10 13:43 ` Dominik Csapak
0 siblings, 0 replies; 5+ messages in thread
From: Dominik Csapak @ 2026-06-10 13:43 UTC (permalink / raw)
To: pve-devel
this is actually v3, sorry^^
On 6/10/26 3:41 PM, Dominik Csapak wrote:
> OVMF can only use PXE/network boot when a virtual RNG device is added
> for VMs, but this is not obvious from the UI or the error behavior.
>
> Add a small warning to the boot order edit that says what is necessary.
>
> Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
> Reviewed-by: Fiona Ebner <f.ebner@proxmox.com>
> ---
> changes from v1:
> * incorporated fionas feedback (thanks!)
> * include r-b trailer from fiona
>
> www/manager6/qemu/BootOrderEdit.js | 16 ++++++++++++++++
> 1 file changed, 16 insertions(+)
>
> diff --git a/www/manager6/qemu/BootOrderEdit.js b/www/manager6/qemu/BootOrderEdit.js
> index 521a3d6e..08e71913 100644
> --- a/www/manager6/qemu/BootOrderEdit.js
> +++ b/www/manager6/qemu/BootOrderEdit.js
> @@ -26,6 +26,7 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> let grid = me.lookup('grid');
> let marker = me.lookup('marker');
> let emptyWarning = me.lookup('emptyWarning');
> + let rngPxeWarning = me.lookup('rngPxeWarning');
>
> marker.originalValue = undefined;
>
> @@ -43,6 +44,14 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> view.inUpdate = false;
> marker.checkDirty();
> emptyWarning.setHidden(val !== '');
> +
> + let showRngPxeWarning =
> + view.vmconfig?.bios === 'ovmf' &&
> + !view.vmconfig?.rng0 &&
> + val?.includes('net');
> +
> + rngPxeWarning.setHidden(!showRngPxeWarning);
> +
> grid.getView().refresh();
> },
> },
> @@ -238,6 +247,13 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> userCls: 'pmx-hint',
> value: gettext('Warning: No devices selected, the VM will probably not boot!'),
> },
> + {
> + xtype: 'displayfield',
> + reference: 'rngPxeWarning',
> + userCls: 'pmx-hint',
> + hidden: true,
> + value: gettext('Warning: For PXE boot with OVMF, you must add a VirtIO RNG device!'),
> + },
> {
> // for dirty marking and 'reset' function
> xtype: 'field',
^ permalink raw reply [flat|nested] 5+ messages in thread
* superseded: [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf
2026-06-09 12:11 [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf Dominik Csapak
2026-06-09 14:48 ` Fiona Ebner
@ 2026-06-10 13:43 ` Dominik Csapak
1 sibling, 0 replies; 5+ messages in thread
From: Dominik Csapak @ 2026-06-10 13:43 UTC (permalink / raw)
To: pve-devel
superseded by v3, which i mislabeled as v2:
https://lore.proxmox.com/pve-devel/20260610134117.3100390-1-d.csapak@proxmox.com/
On 6/9/26 2:11 PM, Dominik Csapak wrote:
> OVMF can only use PXE/network boot when a virtual RNG device is added
> for VMs, but this is not obvious from the UI or the error behavior.
>
> Add a small warning to the boot order edit that says what is necessary.
>
> Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
> ---
> changes from v1:
> * removed stray debug log statement..., sry for the noise
>
> www/manager6/qemu/BootOrderEdit.js | 22 ++++++++++++++++++++++
> 1 file changed, 22 insertions(+)
>
> diff --git a/www/manager6/qemu/BootOrderEdit.js b/www/manager6/qemu/BootOrderEdit.js
> index 521a3d6e..6ae1f506 100644
> --- a/www/manager6/qemu/BootOrderEdit.js
> +++ b/www/manager6/qemu/BootOrderEdit.js
> @@ -26,6 +26,7 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> let grid = me.lookup('grid');
> let marker = me.lookup('marker');
> let emptyWarning = me.lookup('emptyWarning');
> + let rngPxeWarning = me.lookup('rngPxeWarning');
>
> marker.originalValue = undefined;
>
> @@ -43,6 +44,18 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> view.inUpdate = false;
> marker.checkDirty();
> emptyWarning.setHidden(val !== '');
> +
> + let showRngPxeWarning = false;
> + if (
> + view.vmconfig?.bios?.toLowerCase().includes('ovmf') &&
> + !view.vmconfig?.rng0 &&
> + val?.includes('net')
> + ) {
> + showRngPxeWarning = true;
> + }
> +
> + rngPxeWarning.setHidden(!showRngPxeWarning);
> +
> grid.getView().refresh();
> },
> },
> @@ -238,6 +251,15 @@ Ext.define('PVE.qemu.BootOrderPanel', {
> userCls: 'pmx-hint',
> value: gettext('Warning: No devices selected, the VM will probably not boot!'),
> },
> + {
> + xtype: 'displayfield',
> + reference: 'rngPxeWarning',
> + userCls: 'pmx-hint',
> + hidden: true,
> + value: gettext(
> + 'Warning: PXE boot with OVMF only works when a Virtio RNG device is added!',
> + ),
> + },
> {
> // for dirty marking and 'reset' function
> xtype: 'field',
^ permalink raw reply [flat|nested] 5+ messages in thread
end of thread, other threads:[~2026-06-10 13:44 UTC | newest]
Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-06-09 12:11 [PATCH manager v2] ui: qemu: boot order: warn of missing pxe support for ovmf Dominik Csapak
2026-06-09 14:48 ` Fiona Ebner
2026-06-10 13:43 ` superseded: " Dominik Csapak
-- strict thread matches above, loose matches on Subject: below --
2026-06-10 13:40 Dominik Csapak
2026-06-10 13:43 ` Dominik Csapak
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox