public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
* [PATCH installer 0/2] align generated vlan-interface config with our docs
@ 2026-11-24  9:39 Stoiko Ivanov
  2026-11-24  9:39 ` [PATCH installer 1/2] network: align VLAN interface names with the documentation Stoiko Ivanov
                   ` (2 more replies)
  0 siblings, 3 replies; 4+ messages in thread
From: Stoiko Ivanov @ 2026-11-24  9:39 UTC (permalink / raw)
  To: pve-devel

noticed that the generated config if the installer has a vlan-id provided
results in vlanX and vlan-raw-device added.
As I usually use the dot notation $iface.X I checked our docs:
https://pve.proxmox.com/pve-docs/chapter-sysadmin.html#_vlan_on_the_host

I think the issue is mostly cosmetic - but having the generated config
aligned with our docs (and not offering multiple versions in our docs)
should help to avoid confusion (thinking of the boot-loaders, where
we actually need to have multiple versions and the resulting questions
on our support channels).

minimally tested by installing the updated proxmox-installer package
in a VM with the installer booted in debug mode.

Stoiko Ivanov (2):
  network: align VLAN interface names with the documentation
  network: drop unneded vlan-raw-device

 Proxmox/Install.pm                |  4 +--
 test/generate-ifupdown2-config.pl | 52 +++++++++++++------------------
 2 files changed, 23 insertions(+), 33 deletions(-)

-- 
2.47.3





^ permalink raw reply	[flat|nested] 4+ messages in thread

* [PATCH installer 1/2] network: align VLAN interface names with the documentation
  2026-11-24  9:39 [PATCH installer 0/2] align generated vlan-interface config with our docs Stoiko Ivanov
@ 2026-11-24  9:39 ` Stoiko Ivanov
  2026-11-24  9:39 ` [PATCH installer 2/2] network: drop unneded vlan-raw-device Stoiko Ivanov
  2026-11-24 10:24 ` [PATCH installer 0/2] align generated vlan-interface config with our docs Stefan Hanreich
  2 siblings, 0 replies; 4+ messages in thread
From: Stoiko Ivanov @ 2026-11-24  9:39 UTC (permalink / raw)
  To: pve-devel

our documentation has relied on ifupdown(2)'s way of handling
$iface.$vid as identifier for VLAN interfaces for a long while
(looking through pve-docs commit history shows `vlan-raw-device`
only occurring in the api-viewer)

Sticking to our documentation should help reducing the different
ways that people are configuring their interfaces and thus hopefully
the potential for errors.

Signed-off-by: Stoiko Ivanov <s.ivanov@proxmox.com>
---
 Proxmox/Install.pm                |  4 +--
 test/generate-ifupdown2-config.pl | 42 +++++++++++++++----------------
 2 files changed, 23 insertions(+), 23 deletions(-)

diff --git a/Proxmox/Install.pm b/Proxmox/Install.pm
index 76bfd04..337f0d7 100644
--- a/Proxmox/Install.pm
+++ b/Proxmox/Install.pm
@@ -887,9 +887,9 @@ sub generate_ifupdown2_config {
     my $get_vlan_stanza = sub {
         my ($raw_device) = @_;
 
-        my $config = "auto vlan$vlan_id\niface vlan$vlan_id $ntype static\n\taddress $cidr\n";
+        my $config = "auto $raw_device.$vlan_id\niface $raw_device.$vlan_id $ntype static\n\taddress $cidr\n";
         $config .= "\tgateway $gateway\n" if !$is_gateway6_from_ra;
-        return [4, "vlan$vlan_id", $config . "\tvlan-raw-device $raw_device\n"];
+        return [4, "$raw_device.$vlan_id", $config . "\tvlan-raw-device $raw_device\n"];
     };
 
     if ($iso_env->{cfg}->{bridged_network} && defined($vlan_id)) {
diff --git a/test/generate-ifupdown2-config.pl b/test/generate-ifupdown2-config.pl
index a3b7bdb..b33f7a7 100755
--- a/test/generate-ifupdown2-config.pl
+++ b/test/generate-ifupdown2-config.pl
@@ -152,8 +152,8 @@ is_generated(
 auto eno1
 iface eno1 inet manual
 
-auto vlan5
-iface vlan5 inet static
+auto eno1.5
+iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device eno1
@@ -194,8 +194,8 @@ iface bond0 inet manual
 	bond-miimon 100
 	bond-mode active-backup
 
-auto vlan5
-iface vlan5 inet static
+auto bond0.5
+iface bond0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device bond0
@@ -244,8 +244,8 @@ iface vmbr0 inet manual
 	bridge-vlan-aware yes
 	bridge-vids 2-4094
 
-auto vlan5
-iface vlan5 inet static
+auto vmbr0.5
+iface vmbr0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device vmbr0
@@ -304,8 +304,8 @@ iface vmbr0 inet manual
 	bridge-vlan-aware yes
 	bridge-vids 2-4094
 
-auto vlan5
-iface vlan5 inet static
+auto vmbr0.5
+iface vmbr0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device vmbr0
@@ -323,8 +323,8 @@ iface eno1 inet manual
 
 iface eno2 inet manual
 
-auto vlan5
-iface vlan5 inet static
+auto eno1.5
+iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device eno1
@@ -347,8 +347,8 @@ iface bond0 inet manual
 	bond-miimon 100
 	bond-mode active-backup
 
-auto vlan5
-iface vlan5 inet static
+auto bond0.5
+iface bond0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device bond0
@@ -363,8 +363,8 @@ is_generated(
 auto eno1
 iface eno1 inet manual
 
-auto vlan5
-iface vlan5 inet static
+auto eno1.5
+iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
 	vlan-raw-device eno1
@@ -749,8 +749,8 @@ iface bond0 inet6 manual
 	bond-miimon 100
 	bond-mode active-backup
 
-auto vlan5
-iface vlan5 inet6 static
+auto bond0.5
+iface bond0.5 inet6 static
 	address 2001:db8::1/64
 	gateway fe80::1
 	vlan-raw-device bond0
@@ -797,8 +797,8 @@ is_generated(
 auto eno1
 iface eno1 inet6 manual
 
-auto vlan5
-iface vlan5 inet6 static
+auto eno1.5
+iface eno1.5 inet6 static
 	address 2001:db8::1/64
 	vlan-raw-device eno1
 
@@ -822,8 +822,8 @@ iface vmbr0 inet6 manual
 	bridge-vlan-aware yes
 	bridge-vids 2-4094
 
-auto vlan5
-iface vlan5 inet6 static
+auto vmbr0.5
+iface vmbr0.5 inet6 static
 	address 2001:db8::1/64
 	vlan-raw-device vmbr0
 EOT
@@ -834,7 +834,7 @@ set_config(bridge => 0, bond => 0, vlan => 1);
 Proxmox::Install::Config::merge({ mngmt_vlan => { enabled => 1, vid => 200 } });
 like(
     Proxmox::Install::generate_ifupdown2_config(),
-    qr/^iface vlan200 inet6 static\n\taddress 2001:db8::1\/64\n\tgateway fe80::1\n/m,
+    qr/^iface eno1.200 inet6 static\n\taddress 2001:db8::1\/64\n\tgateway fe80::1\n/m,
     'management VLAN other than the installation environment one gets the configured gateway',
 );
 
-- 
2.47.3





^ permalink raw reply related	[flat|nested] 4+ messages in thread

* [PATCH installer 2/2] network: drop unneded vlan-raw-device
  2026-11-24  9:39 [PATCH installer 0/2] align generated vlan-interface config with our docs Stoiko Ivanov
  2026-11-24  9:39 ` [PATCH installer 1/2] network: align VLAN interface names with the documentation Stoiko Ivanov
@ 2026-11-24  9:39 ` Stoiko Ivanov
  2026-11-24 10:24 ` [PATCH installer 0/2] align generated vlan-interface config with our docs Stefan Hanreich
  2 siblings, 0 replies; 4+ messages in thread
From: Stoiko Ivanov @ 2026-11-24  9:39 UTC (permalink / raw)
  To: pve-devel

with the previous patch using $iface.$vid the vlan-raw-device and
vlan-id setting should not be needed anymore based on my experience.

fwiw ifupdown-addons-interfaces(5) agrees, but also says, that
if you don't use the dot notation you need to provide both
vlan-raw-device _and_ vlan-id (which does not match my experience).

Sending as separate patch - on the chance that I missed some
combination where vlan-raw-device and(/or) vlan-id are needed/make
sense.

Signed-off-by: Stoiko Ivanov <s.ivanov@proxmox.com>
---
 Proxmox/Install.pm                |  2 +-
 test/generate-ifupdown2-config.pl | 10 ----------
 2 files changed, 1 insertion(+), 11 deletions(-)

diff --git a/Proxmox/Install.pm b/Proxmox/Install.pm
index 337f0d7..d20777e 100644
--- a/Proxmox/Install.pm
+++ b/Proxmox/Install.pm
@@ -889,7 +889,7 @@ sub generate_ifupdown2_config {
 
         my $config = "auto $raw_device.$vlan_id\niface $raw_device.$vlan_id $ntype static\n\taddress $cidr\n";
         $config .= "\tgateway $gateway\n" if !$is_gateway6_from_ra;
-        return [4, "$raw_device.$vlan_id", $config . "\tvlan-raw-device $raw_device\n"];
+        return [4, "$raw_device.$vlan_id", $config];
     };
 
     if ($iso_env->{cfg}->{bridged_network} && defined($vlan_id)) {
diff --git a/test/generate-ifupdown2-config.pl b/test/generate-ifupdown2-config.pl
index b33f7a7..a76c618 100755
--- a/test/generate-ifupdown2-config.pl
+++ b/test/generate-ifupdown2-config.pl
@@ -156,7 +156,6 @@ auto eno1.5
 iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device eno1
 
 iface eno2 inet manual
 EOT
@@ -198,7 +197,6 @@ auto bond0.5
 iface bond0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device bond0
 
 auto eno1
 iface eno1 inet manual
@@ -248,7 +246,6 @@ auto vmbr0.5
 iface vmbr0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device vmbr0
 EOT
     , 'host network setup',
 );
@@ -308,7 +305,6 @@ auto vmbr0.5
 iface vmbr0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device vmbr0
 EOT
     , 'host network setup',
 );
@@ -327,7 +323,6 @@ auto eno1.5
 iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device eno1
 EOT
     , 'interfaces ordered like the network API',
 );
@@ -351,7 +346,6 @@ auto bond0.5
 iface bond0.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device bond0
 EOT
     , 'interfaces ordered like the network API',
 );
@@ -367,7 +361,6 @@ auto eno1.5
 iface eno1.5 inet static
 	address 192.168.0.10/24
 	gateway 192.168.0.1
-	vlan-raw-device eno1
 
 iface eno2 inet manual
 EOT
@@ -753,7 +746,6 @@ auto bond0.5
 iface bond0.5 inet6 static
 	address 2001:db8::1/64
 	gateway fe80::1
-	vlan-raw-device bond0
 
 auto eno1
 iface eno1 inet6 manual
@@ -800,7 +792,6 @@ iface eno1 inet6 manual
 auto eno1.5
 iface eno1.5 inet6 static
 	address 2001:db8::1/64
-	vlan-raw-device eno1
 
 iface eno2 inet6 manual
 EOT
@@ -825,7 +816,6 @@ iface vmbr0 inet6 manual
 auto vmbr0.5
 iface vmbr0.5 inet6 static
 	address 2001:db8::1/64
-	vlan-raw-device vmbr0
 EOT
     , 'gateway learned from router advertisements on the management VLAN on a bridge is not configured',
 );
-- 
2.47.3





^ permalink raw reply related	[flat|nested] 4+ messages in thread

* Re: [PATCH installer 0/2] align generated vlan-interface config with our docs
  2026-11-24  9:39 [PATCH installer 0/2] align generated vlan-interface config with our docs Stoiko Ivanov
  2026-11-24  9:39 ` [PATCH installer 1/2] network: align VLAN interface names with the documentation Stoiko Ivanov
  2026-11-24  9:39 ` [PATCH installer 2/2] network: drop unneded vlan-raw-device Stoiko Ivanov
@ 2026-11-24 10:24 ` Stefan Hanreich
  2 siblings, 0 replies; 4+ messages in thread
From: Stefan Hanreich @ 2026-11-24 10:24 UTC (permalink / raw)
  To: pve-devel

On 11/24/26 10:40 AM, Stoiko Ivanov wrote:
> noticed that the generated config if the installer has a vlan-id provided
> results in vlanX and vlan-raw-device added.
> As I usually use the dot notation $iface.X I checked our docs:
> https://pve.proxmox.com/pve-docs/chapter-sysadmin.html#_vlan_on_the_host

strongly agree, but we also need a fallback for when the interface name is
too long!

> I think the issue is mostly cosmetic - but having the generated config
> aligned with our docs (and not offering multiple versions in our docs)
> should help to avoid confusion (thinking of the boot-loaders, where
> we actually need to have multiple versions and the resulting questions
> on our support channels).
> 
> minimally tested by installing the updated proxmox-installer package
> in a VM with the installer booted in debug mode.




^ permalink raw reply	[flat|nested] 4+ messages in thread

end of thread, other threads:[~2026-11-24 10:24 UTC | newest]

Thread overview: 4+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-11-24  9:39 [PATCH installer 0/2] align generated vlan-interface config with our docs Stoiko Ivanov
2026-11-24  9:39 ` [PATCH installer 1/2] network: align VLAN interface names with the documentation Stoiko Ivanov
2026-11-24  9:39 ` [PATCH installer 2/2] network: drop unneded vlan-raw-device Stoiko Ivanov
2026-11-24 10:24 ` [PATCH installer 0/2] align generated vlan-interface config with our docs Stefan Hanreich

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal