all lists on lists.proxmox.com
 help / color / mirror / Atom feed
* [PATCH qemu-server v5 0/4] hotplug: improve and fix cleanup/error handling
@ 2026-10-30 10:04 Dominik Csapak
  2026-10-30 10:04 ` [PATCH qemu-server v5 1/4] hotplug: scsi: only keep controller if a disk on it is still present Dominik Csapak
                   ` (3 more replies)
  0 siblings, 4 replies; 5+ messages in thread
From: Dominik Csapak @ 2026-10-30 10:04 UTC (permalink / raw)
  To: pve-devel

This replaces my earlier v4 9/9 patch[0]

It uses a different approach now by unifying the cleanup and removal of
disks and their controllers.

It also fixes a related bug in 1/4 that was uncovered.

changes from v4:
* rebase on master
* new bugfix (1/4)
* new patch for iothread deletion
* new patch for refactoring the cleanup

0: https://lore.proxmox.com/pve-devel/20261023130324.451252-10-d.csapak@proxmox.com/

Dominik Csapak (4):
  hotplug: scsi: only keep controller if a disk on it is still present
  hotplug: remove iothread with virtio-scsi controller together
  hotplug: factor out cleanup of disk devices
  hotplug: clean up disk devices/objects if adding them failed

 src/PVE/QemuServer.pm                         | 107 ++++++++++--------
 src/test/hotplug/disk-add-fail.conf           |  19 ++++
 src/test/hotplug/disk-add-fail.conf.expected  |  10 ++
 .../disk-add-scsi-single-disk-fail.conf       |  19 ++++
 ...sk-add-scsi-single-disk-fail.conf.expected |  12 ++
 .../hotplug/disk-add-scsi-single-fail.conf    |  19 ++++
 .../disk-add-scsi-single-fail.conf.expected   |   5 +
 .../hotplug/disk-remove-lsi-last-slot.conf    |  16 +++
 .../disk-remove-lsi-last-slot.conf.expected   |   3 +
 .../disk-remove-lsi-second-controller.conf    |  16 +++
 ...remove-lsi-second-controller.conf.expected |   4 +
 11 files changed, 183 insertions(+), 47 deletions(-)
 create mode 100644 src/test/hotplug/disk-add-fail.conf
 create mode 100644 src/test/hotplug/disk-add-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-add-scsi-single-disk-fail.conf
 create mode 100644 src/test/hotplug/disk-add-scsi-single-disk-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-add-scsi-single-fail.conf
 create mode 100644 src/test/hotplug/disk-add-scsi-single-fail.conf.expected
 create mode 100644 src/test/hotplug/disk-remove-lsi-last-slot.conf
 create mode 100644 src/test/hotplug/disk-remove-lsi-last-slot.conf.expected
 create mode 100644 src/test/hotplug/disk-remove-lsi-second-controller.conf
 create mode 100644 src/test/hotplug/disk-remove-lsi-second-controller.conf.expected

-- 
2.47.3





^ permalink raw reply	[flat|nested] 5+ messages in thread

end of thread, other threads:[~2026-10-30 10:12 UTC | newest]

Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-10-30 10:04 [PATCH qemu-server v5 0/4] hotplug: improve and fix cleanup/error handling Dominik Csapak
2026-10-30 10:04 ` [PATCH qemu-server v5 1/4] hotplug: scsi: only keep controller if a disk on it is still present Dominik Csapak
2026-10-30 10:04 ` [PATCH qemu-server v5 2/4] hotplug: remove iothread with virtio-scsi controller together Dominik Csapak
2026-10-30 10:04 ` [PATCH qemu-server v5 3/4] hotplug: factor out cleanup of disk devices Dominik Csapak
2026-10-30 10:04 ` [PATCH qemu-server v5 4/4] hotplug: clean up disk devices/objects if adding them failed Dominik Csapak

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal