Ok,  I understand the case.

29.12.2021 16:13, Uwe Sauter пишет:
> Am 29.12.21 um 13:51 schrieb Сергей Цаболов:
>> Hi, Uwe
>>
>> 29.12.2021 14:16, Uwe Sauter пишет:
>>> Just a feeling but I'd say that the imbalance in OSDs (one host having many more disks than the
>>> rest) is your problem.
>> Yes, last node in cluster have more disk then the rest, but
>>
>> one disk is 12TB and all others 9 HD is 1TB
>>
>>> Assuming that your configuration keeps 3 copies of each VM image then the imbalance probably means
>>> that 2 of these 3 copies reside on pve-3111 and if this host is unavailable, all VM images with 2
>>> copies on that host become unresponsive, too.
>> In Proxmox web ceph pool I set the  Size: 2 , Min.Size: 2
>>
> So this means that you want to have 2 copies in the regular case (size) and also 2 copies in the
> failure case (min size) so that the VMs stay available.
Yes I think before like you answer, but is not so worked.
>
> So you might solve your problem by decreasing min size to 1 (dangerous!!) or by increasing size to
> 3, which means that in the regular case you will have 3 copies but if only 2 are available, it will
> still work and re-sync the 3rd copy once it comes online again.

I understand if decreasing min.size to 1 is very (dangerous!!!)

If I increasing to 3 min.size keep 2 is default .

But I'm afraid if set the 3/2 (good choice) MAX AVAIL in pool is will 
decrease in two or more space, or am I wrong?

For now I have with all disk :

CLASS  SIZE         AVAIL       USED         RAW USED  %RAW USED
hdd    `106 TiB      99 TiB      7.7 TiB       7.7 TiB       7.26
TOTAL  106 TiB      99 TiB      7.7 TiB       7.7 TiB       7.26

--- POOLS ---
POOL                             ID      PGS       STORED OBJECTS  
USED         %USED      MAX AVAIL
device_health_metrics   1         1          8.3 MiB 22   17 MiB      
         0             44 TiB
vm.pool                         2          1024    3.0 TiB   864.55k  
6.0 TiB       6.39         44 TiB ( terminal 44 TiB = 48.37 ) in web I 
see  51.50 TB
cephfs_data                   3         32         874 GiB 223.76k  1.7 
TiB       1.91         44 TiB
cephfs_metadata            4        32           25 MiB 27   51 MiB      
0                       44 TiB


Am I right in my reasoning ?

Thank you!



>
>> With :  ceph osd map vm.pool object-name (vm ID) I see some of vm object one copy is on osd.12,
>> example :
>>
>> osdmap e14321 pool 'vm.pool' (2) object '114' -> pg 2.10486407 (2.7) -> up ([12,8], p12) acting
>> ([12,8], p12)
>>
>> But this example :
>>
>> osdmap e14321 pool 'vm.pool' (2) object '113' -> pg 2.8bd09f6d (2.36d) -> up ([10,7], p10) acting
>> ([10,7], p10)
>>
>> osd.10 and osd.7
>>
>>> Check your failure domain for Ceph and possibly change it from OSD to host. This should prevent that
>>> one host holds multiple copies of a VM image.
>> I didn 't understand a little what to check  ?
>>
>> Can you explain me with example?
>>
> I don't have an example but you can read about the concept at:
>
> https://docs.ceph.com/en/latest/rados/operations/crush-map/#crush-maps
>
>
> Regards,
>
> 	Uwe
>
>
>
>>>
>>> Regards,
>>>
>>>      Uwe
>>>
>>> Am 29.12.21 um 09:36 schrieb Сергей Цаболов:
>>>> Hello to all.
>>>>
>>>> In my case I have the 7 node cluster Proxmox and working Ceph (ceph version 15.2.15  octopus
>>>> (stable)": 7)
>>>>
>>>> Ceph HEALTH_OK
>>>>
>>>> ceph -s
>>>>     cluster:
>>>>       id:     9662e3fa-4ce6-41df-8d74-5deaa41a8dde
>>>>       health: HEALTH_OK
>>>>
>>>>     services:
>>>>       mon: 7 daemons, quorum pve-3105,pve-3107,pve-3108,pve-3103,pve-3101,pve-3111,pve-3109 (age 17h)
>>>>       mgr: pve-3107(active, since 41h), standbys: pve-3109, pve-3103, pve-3105, pve-3101, pve-3111,
>>>> pve-3108
>>>>       mds: cephfs:1 {0=pve-3105=up:active} 6 up:standby
>>>>       osd: 22 osds: 22 up (since 17h), 22 in (since 17h)
>>>>
>>>>     task status:
>>>>
>>>>     data:
>>>>       pools:   4 pools, 1089 pgs
>>>>       objects: 1.09M objects, 4.1 TiB
>>>>       usage:   7.7 TiB used, 99 TiB / 106 TiB avail
>>>>       pgs:     1089 active+clean
>>>>
>>>> ---------------------------------------------------------------------------------------------------------------------
>>>>
>>>>
>>>>
>>>> ceph osd tree
>>>>
>>>> ID   CLASS  WEIGHT     TYPE NAME            STATUS  REWEIGHT PRI-AFF
>>>>    -1         106.43005  root default
>>>> -13          14.55478      host pve-3101
>>>>    10    hdd    7.27739          osd.10           up   1.00000 1.00000
>>>>    11    hdd    7.27739          osd.11           up   1.00000 1.00000
>>>> -11          14.55478      host pve-3103
>>>>     8    hdd    7.27739          osd.8            up   1.00000 1.00000
>>>>     9    hdd    7.27739          osd.9            up   1.00000 1.00000
>>>>    -3          14.55478      host pve-3105
>>>>     0    hdd    7.27739          osd.0            up   1.00000 1.00000
>>>>     1    hdd    7.27739          osd.1            up   1.00000 1.00000
>>>>    -5          14.55478      host pve-3107
>>>>     2    hdd    7.27739          osd.2            up   1.00000 1.00000
>>>>     3    hdd    7.27739          osd.3            up   1.00000 1.00000
>>>>    -9          14.55478      host pve-3108
>>>>     6    hdd    7.27739          osd.6            up   1.00000 1.00000
>>>>     7    hdd    7.27739          osd.7            up   1.00000 1.00000
>>>>    -7          14.55478      host pve-3109
>>>>     4    hdd    7.27739          osd.4            up   1.00000 1.00000
>>>>     5    hdd    7.27739          osd.5            up   1.00000 1.00000
>>>> -15          19.10138      host pve-3111
>>>>    12    hdd   10.91409          osd.12           up   1.00000 1.00000
>>>>    13    hdd    0.90970          osd.13           up   1.00000 1.00000
>>>>    14    hdd    0.90970          osd.14           up   1.00000 1.00000
>>>>    15    hdd    0.90970          osd.15           up   1.00000 1.00000
>>>>    16    hdd    0.90970          osd.16           up   1.00000 1.00000
>>>>    17    hdd    0.90970          osd.17           up   1.00000 1.00000
>>>>    18    hdd    0.90970          osd.18           up   1.00000 1.00000
>>>>    19    hdd    0.90970          osd.19           up   1.00000 1.00000
>>>>    20    hdd    0.90970          osd.20           up   1.00000 1.00000
>>>>    21    hdd    0.90970          osd.21           up   1.00000 1.00000
>>>>
>>>> ---------------------------------------------------------------------------------------------------------------
>>>>
>>>>
>>>>
>>>> POOL                               ID  PGS   STORED   OBJECTS USED     %USED  MAX AVAIL
>>>> vm.pool                            2  1024  3.0 TiB  863.31k  6.0 TiB   6.38     44 TiB  (this pool
>>>> have the all VM disk)
>>>>
>>>> ---------------------------------------------------------------------------------------------------------------
>>>>
>>>>
>>>>
>>>> ceph osd map vm.pool vm.pool.object
>>>> osdmap e14319 pool 'vm.pool' (2) object 'vm.pool.object' -> pg 2.196f68d5 (2.d5) -> up ([2,4], p2)
>>>> acting ([2,4], p2)
>>>>
>>>> -----------------------------------------------------------------------------------------------------------------------------------------------------------------------
>>>>
>>>>
>>>> pveversion -v
>>>> proxmox-ve: 6.4-1 (running kernel: 5.4.143-1-pve)
>>>> pve-manager: 6.4-13 (running version: 6.4-13/9f411e79)
>>>> pve-kernel-helper: 6.4-8
>>>> pve-kernel-5.4: 6.4-7
>>>> pve-kernel-5.4.143-1-pve: 5.4.143-1
>>>> pve-kernel-5.4.106-1-pve: 5.4.106-1
>>>> ceph: 15.2.15-pve1~bpo10
>>>> ceph-fuse: 15.2.15-pve1~bpo10
>>>> corosync: 3.1.2-pve1
>>>> criu: 3.11-3
>>>> glusterfs-client: 5.5-3
>>>> ifupdown: residual config
>>>> ifupdown2: 3.0.0-1+pve4~bpo10
>>>> ksm-control-daemon: 1.3-1
>>>> libjs-extjs: 6.0.1-10
>>>> libknet1: 1.22-pve1~bpo10+1
>>>> libproxmox-acme-perl: 1.1.0
>>>> libproxmox-backup-qemu0: 1.1.0-1
>>>> libpve-access-control: 6.4-3
>>>> libpve-apiclient-perl: 3.1-3
>>>> libpve-common-perl: 6.4-4
>>>> libpve-guest-common-perl: 3.1-5
>>>> libpve-http-server-perl: 3.2-3
>>>> libpve-storage-perl: 6.4-1
>>>> libqb0: 1.0.5-1
>>>> libspice-server1: 0.14.2-4~pve6+1
>>>> lvm2: 2.03.02-pve4
>>>> lxc-pve: 4.0.6-2
>>>> lxcfs: 4.0.6-pve1
>>>> novnc-pve: 1.1.0-1
>>>> proxmox-backup-client: 1.1.13-2
>>>> proxmox-mini-journalreader: 1.1-1
>>>> proxmox-widget-toolkit: 2.6-1
>>>> pve-cluster: 6.4-1
>>>> pve-container: 3.3-6
>>>> pve-docs: 6.4-2
>>>> pve-edk2-firmware: 2.20200531-1
>>>> pve-firewall: 4.1-4
>>>> pve-firmware: 3.3-2
>>>> pve-ha-manager: 3.1-1
>>>> pve-i18n: 2.3-1
>>>> pve-qemu-kvm: 5.2.0-6
>>>> pve-xtermjs: 4.7.0-3
>>>> qemu-server: 6.4-2
>>>> smartmontools: 7.2-pve2
>>>> spiceterm: 3.1-1
>>>> vncterm: 1.6-2
>>>> zfsutils-linux: 2.0.6-pve1~bpo10+1
>>>>
>>>> -----------------------------------------------------------------------------------------------------------------------------------------------------------------------
>>>>
>>>>
>>>>
>>>> And now my problem:
>>>>
>>>> For all VM I have one pool for VM disks
>>>>
>>>> When  node/host pve-3111  is shutdown in many of other nodes/hosts pve-3107, pve-3105  VM not
>>>> shutdown but not available in network.
>>>>
>>>> After the node/host is up Ceph back to HEALTH_OK and the all VM back to access in Network (without
>>>> reboot).
>>>>
>>>> Can some one to suggest me what I can to check in Ceph ?
>>>>
>>>> Thanks.
>>>>
>
-- 
-------------------------
С уважением
Сергей Цаболов,
Системный администратор
ООО "Т8"
Тел.: +74992716161,
Моб: +79850334875
tsabolov@t8.ru
ООО «Т8», 107076, г. Москва, Краснобогатырская ул., д. 44, стр.1
www.t8.ru




  reply	other threads:[~2021-12-29 14:06 UTC|newest]

Thread overview: 6+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
     [not found] <e6b7d3f3-d6ce-ef41-cfa8-36b011243ebc@t8.ru>
     [not found] ` <6f23d719-1931-cc81-899d-3202047c4a56@binovo.es>
     [not found]   ` <101971ad-519a-9af2-249e-433df28b1f1a@t8.ru>
2021-12-29  8:36     ` Сергей Цаболов
2021-12-29 11:16       ` Uwe Sauter
2021-12-29 12:51         ` Сергей Цаболов
2021-12-29 13:13           ` Uwe Sauter
2021-12-29 14:06             ` Сергей Цаболов [this message]
2021-12-29 14:13               ` Uwe Sauter

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=131ea5ec-89df-4c90-5808-451c33abbb05@t8.ru \
    --to=tsabolov@t8.ru \
    --cc=pve-user@lists.proxmox.com \
    --cc=uwe.sauter.de@gmail.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal