public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
* [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
@ 2021-03-01  9:42 Fabian Ebner
  2021-03-01  9:54 ` Stefan Reiter
  2021-03-01 10:23 ` Fabian Ebner
  0 siblings, 2 replies; 9+ messages in thread
From: Fabian Ebner @ 2021-03-01  9:42 UTC (permalink / raw)
  To: pve-devel

Moving to Ceph is very slow when bs=1. Instead, use the biggest possible power
of two <= 1024. At the moment our EFI image sizes are multiples of 1024, so
just using 1024 wouldn't be a problem, but this feels more future-proof.

Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
---

I did not see an way for 'qemu-img dd' to use a larger blocksize while still
specifying the exact total size if it is not a multiple of the blocksize.

 PVE/QemuServer.pm | 10 +++++++++-
 1 file changed, 9 insertions(+), 1 deletion(-)

diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
index f401baf..e579cdf 100644
--- a/PVE/QemuServer.pm
+++ b/PVE/QemuServer.pm
@@ -6991,7 +6991,15 @@ sub clone_disk {
 		# that is given by the OVMF_VARS.fd
 		my $src_path = PVE::Storage::path($storecfg, $drive->{file});
 		my $dst_path = PVE::Storage::path($storecfg, $newvolid);
-		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=1", "count=$size",
+
+		# Ceph doesn't like too small blocksize, see bug #3324
+		my $bs = 1;
+		while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
+		    $bs *= 2;
+		}
+		my $count = $size / $bs;
+
+		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=$bs", "count=$count",
 		    "if=$src_path", "of=$dst_path"]);
 	    } else {
 		qemu_img_convert($drive->{file}, $newvolid, $size, $snapname, $sparseinit);
-- 
2.20.1





^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01  9:42 [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible Fabian Ebner
@ 2021-03-01  9:54 ` Stefan Reiter
  2021-03-01 10:06   ` Fabian Ebner
  2021-03-01 10:23 ` Fabian Ebner
  1 sibling, 1 reply; 9+ messages in thread
From: Stefan Reiter @ 2021-03-01  9:54 UTC (permalink / raw)
  To: pve-devel

On 3/1/21 10:42 AM, Fabian Ebner wrote:
> Moving to Ceph is very slow when bs=1. Instead, use the biggest possible power
> of two <= 1024. At the moment our EFI image sizes are multiples of 1024, so
> just using 1024 wouldn't be a problem, but this feels more future-proof.
> 
> Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
> ---
> 
> I did not see an way for 'qemu-img dd' to use a larger blocksize while still
> specifying the exact total size if it is not a multiple of the blocksize.
>

Could it make sense to just set the block size equal to the image size 
with count=1 ? Since the images will always be very small anyway...

>   PVE/QemuServer.pm | 10 +++++++++-
>   1 file changed, 9 insertions(+), 1 deletion(-)
> 
> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
> index f401baf..e579cdf 100644
> --- a/PVE/QemuServer.pm
> +++ b/PVE/QemuServer.pm
> @@ -6991,7 +6991,15 @@ sub clone_disk {
>   		# that is given by the OVMF_VARS.fd
>   		my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>   		my $dst_path = PVE::Storage::path($storecfg, $newvolid);
> -		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=1", "count=$size",
> +
> +		# Ceph doesn't like too small blocksize, see bug #3324
> +		my $bs = 1;
> +		while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
> +		    $bs *= 2;
> +		}
> +		my $count = $size / $bs;
> +
> +		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=$bs", "count=$count",
>   		    "if=$src_path", "of=$dst_path"]);
>   	    } else {
>   		qemu_img_convert($drive->{file}, $newvolid, $size, $snapname, $sparseinit);
> 




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01  9:54 ` Stefan Reiter
@ 2021-03-01 10:06   ` Fabian Ebner
  2021-03-01 10:13     ` Stefan Reiter
  0 siblings, 1 reply; 9+ messages in thread
From: Fabian Ebner @ 2021-03-01 10:06 UTC (permalink / raw)
  To: Stefan Reiter, pve-devel

Am 01.03.21 um 10:54 schrieb Stefan Reiter:
> On 3/1/21 10:42 AM, Fabian Ebner wrote:
>> Moving to Ceph is very slow when bs=1. Instead, use the biggest 
>> possible power
>> of two <= 1024. At the moment our EFI image sizes are multiples of 
>> 1024, so
>> just using 1024 wouldn't be a problem, but this feels more future-proof.
>>
>> Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
>> ---
>>
>> I did not see an way for 'qemu-img dd' to use a larger blocksize while 
>> still
>> specifying the exact total size if it is not a multiple of the blocksize.
>>
> 
> Could it make sense to just set the block size equal to the image size 
> with count=1 ? Since the images will always be very small anyway...
> 

Note that AAVMF_VARS.fd is 64 MiB. Are blocksizes that big a good idea?

>>   PVE/QemuServer.pm | 10 +++++++++-
>>   1 file changed, 9 insertions(+), 1 deletion(-)
>>
>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
>> index f401baf..e579cdf 100644
>> --- a/PVE/QemuServer.pm
>> +++ b/PVE/QemuServer.pm
>> @@ -6991,7 +6991,15 @@ sub clone_disk {
>>           # that is given by the OVMF_VARS.fd
>>           my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>>           my $dst_path = PVE::Storage::path($storecfg, $newvolid);
>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>> "bs=1", "count=$size",
>> +
>> +        # Ceph doesn't like too small blocksize, see bug #3324
>> +        my $bs = 1;
>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
>> +            $bs *= 2;
>> +        }
>> +        my $count = $size / $bs;
>> +
>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>> "bs=$bs", "count=$count",
>>               "if=$src_path", "of=$dst_path"]);
>>           } else {
>>           qemu_img_convert($drive->{file}, $newvolid, $size, 
>> $snapname, $sparseinit);
>>




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01 10:06   ` Fabian Ebner
@ 2021-03-01 10:13     ` Stefan Reiter
  2021-03-01 10:18       ` Dietmar Maurer
  2021-03-01 10:19       ` Fabian Ebner
  0 siblings, 2 replies; 9+ messages in thread
From: Stefan Reiter @ 2021-03-01 10:13 UTC (permalink / raw)
  To: Fabian Ebner, pve-devel

On 3/1/21 11:06 AM, Fabian Ebner wrote:
> Am 01.03.21 um 10:54 schrieb Stefan Reiter:
>> On 3/1/21 10:42 AM, Fabian Ebner wrote:
>>> Moving to Ceph is very slow when bs=1. Instead, use the biggest 
>>> possible power
>>> of two <= 1024. At the moment our EFI image sizes are multiples of 
>>> 1024, so
>>> just using 1024 wouldn't be a problem, but this feels more future-proof.
>>>
>>> Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
>>> ---
>>>
>>> I did not see an way for 'qemu-img dd' to use a larger blocksize 
>>> while still
>>> specifying the exact total size if it is not a multiple of the 
>>> blocksize.
>>>
>>
>> Could it make sense to just set the block size equal to the image size 
>> with count=1 ? Since the images will always be very small anyway...
>>
> 
> Note that AAVMF_VARS.fd is 64 MiB. Are blocksizes that big a good idea?
> 

That'd be too much, but the VARS file shouldn't be copied anyway? Only 
the efidisk attached to the VM?

>>>   PVE/QemuServer.pm | 10 +++++++++-
>>>   1 file changed, 9 insertions(+), 1 deletion(-)
>>>
>>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
>>> index f401baf..e579cdf 100644
>>> --- a/PVE/QemuServer.pm
>>> +++ b/PVE/QemuServer.pm
>>> @@ -6991,7 +6991,15 @@ sub clone_disk {
>>>           # that is given by the OVMF_VARS.fd
>>>           my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>>>           my $dst_path = PVE::Storage::path($storecfg, $newvolid);
>>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>>> "bs=1", "count=$size",
>>> +
>>> +        # Ceph doesn't like too small blocksize, see bug #3324
>>> +        my $bs = 1;
>>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
>>> +            $bs *= 2;
>>> +        }
>>> +        my $count = $size / $bs;
>>> +
>>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>>> "bs=$bs", "count=$count",
>>>               "if=$src_path", "of=$dst_path"]);
>>>           } else {
>>>           qemu_img_convert($drive->{file}, $newvolid, $size, 
>>> $snapname, $sparseinit);
>>>




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01 10:13     ` Stefan Reiter
@ 2021-03-01 10:18       ` Dietmar Maurer
  2021-03-01 10:22         ` Fabian Ebner
  2021-03-02  7:11         ` Fabian Ebner
  2021-03-01 10:19       ` Fabian Ebner
  1 sibling, 2 replies; 9+ messages in thread
From: Dietmar Maurer @ 2021-03-01 10:18 UTC (permalink / raw)
  To: Proxmox VE development discussion, Stefan Reiter, Fabian Ebner


> >>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
> >>> index f401baf..e579cdf 100644
> >>> --- a/PVE/QemuServer.pm
> >>> +++ b/PVE/QemuServer.pm
> >>> @@ -6991,7 +6991,15 @@ sub clone_disk {
> >>>           # that is given by the OVMF_VARS.fd
> >>>           my $src_path = PVE::Storage::path($storecfg, $drive->{file});
> >>>           my $dst_path = PVE::Storage::path($storecfg, $newvolid);
> >>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
> >>> "bs=1", "count=$size",
> >>> +
> >>> +        # Ceph doesn't like too small blocksize, see bug #3324
> >>> +        my $bs = 1;
> >>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
> >>> +            $bs *= 2;
> >>> +        }

now, $size % $bs != 0

I guess this is wrong...

> >>> +        my $count = $size / $bs;
> >>> +
> >>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
> >>> "bs=$bs", "count=$count",
> >>>               "if=$src_path", "of=$dst_path"]);
> >>>           } else {
> >>>           qemu_img_convert($drive->{file}, $newvolid, $size, 
> >>> $snapname, $sparseinit);
> >>>
> 
> 
> _______________________________________________
> pve-devel mailing list
> pve-devel@lists.proxmox.com
> https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01 10:13     ` Stefan Reiter
  2021-03-01 10:18       ` Dietmar Maurer
@ 2021-03-01 10:19       ` Fabian Ebner
  1 sibling, 0 replies; 9+ messages in thread
From: Fabian Ebner @ 2021-03-01 10:19 UTC (permalink / raw)
  To: Stefan Reiter, pve-devel

Am 01.03.21 um 11:13 schrieb Stefan Reiter:
> On 3/1/21 11:06 AM, Fabian Ebner wrote:
>> Am 01.03.21 um 10:54 schrieb Stefan Reiter:
>>> On 3/1/21 10:42 AM, Fabian Ebner wrote:
>>>> Moving to Ceph is very slow when bs=1. Instead, use the biggest 
>>>> possible power
>>>> of two <= 1024. At the moment our EFI image sizes are multiples of 
>>>> 1024, so
>>>> just using 1024 wouldn't be a problem, but this feels more 
>>>> future-proof.
>>>>
>>>> Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
>>>> ---
>>>>
>>>> I did not see an way for 'qemu-img dd' to use a larger blocksize 
>>>> while still
>>>> specifying the exact total size if it is not a multiple of the 
>>>> blocksize.
>>>>
>>>
>>> Could it make sense to just set the block size equal to the image 
>>> size with count=1 ? Since the images will always be very small anyway...
>>>
>>
>> Note that AAVMF_VARS.fd is 64 MiB. Are blocksizes that big a good idea?
>>
> 
> That'd be too much, but the VARS file shouldn't be copied anyway? Only 
> the efidisk attached to the VM?
> 

AFAICT that's the file used for the EFI disk.

>>>>   PVE/QemuServer.pm | 10 +++++++++-
>>>>   1 file changed, 9 insertions(+), 1 deletion(-)
>>>>
>>>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
>>>> index f401baf..e579cdf 100644
>>>> --- a/PVE/QemuServer.pm
>>>> +++ b/PVE/QemuServer.pm
>>>> @@ -6991,7 +6991,15 @@ sub clone_disk {
>>>>           # that is given by the OVMF_VARS.fd
>>>>           my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>>>>           my $dst_path = PVE::Storage::path($storecfg, $newvolid);
>>>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>>>> "bs=1", "count=$size",
>>>> +
>>>> +        # Ceph doesn't like too small blocksize, see bug #3324
>>>> +        my $bs = 1;
>>>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
>>>> +            $bs *= 2;
>>>> +        }
>>>> +        my $count = $size / $bs;
>>>> +
>>>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, 
>>>> "bs=$bs", "count=$count",
>>>>               "if=$src_path", "of=$dst_path"]);
>>>>           } else {
>>>>           qemu_img_convert($drive->{file}, $newvolid, $size, 
>>>> $snapname, $sparseinit);
>>>>




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01 10:18       ` Dietmar Maurer
@ 2021-03-01 10:22         ` Fabian Ebner
  2021-03-02  7:11         ` Fabian Ebner
  1 sibling, 0 replies; 9+ messages in thread
From: Fabian Ebner @ 2021-03-01 10:22 UTC (permalink / raw)
  To: Dietmar Maurer, Proxmox VE development discussion, Stefan Reiter

Am 01.03.21 um 11:18 schrieb Dietmar Maurer:
> 
>>>>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
>>>>> index f401baf..e579cdf 100644
>>>>> --- a/PVE/QemuServer.pm
>>>>> +++ b/PVE/QemuServer.pm
>>>>> @@ -6991,7 +6991,15 @@ sub clone_disk {
>>>>>            # that is given by the OVMF_VARS.fd
>>>>>            my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>>>>>            my $dst_path = PVE::Storage::path($storecfg, $newvolid);
>>>>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format,
>>>>> "bs=1", "count=$size",
>>>>> +
>>>>> +        # Ceph doesn't like too small blocksize, see bug #3324
>>>>> +        my $bs = 1;
>>>>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
>>>>> +            $bs *= 2;
>>>>> +        }
> 
> now, $size % $bs != 0
> 
> I guess this is wrong...
> 

No, because of the $bs < $size check first. If we enter the loop, $size 
was a multiple of $bs and at least twice $bs. I wrote it like this 
because it'd avoid an endless loop if for whatever reason $size is 0.

>>>>> +        my $count = $size / $bs;
>>>>> +
>>>>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format,
>>>>> "bs=$bs", "count=$count",
>>>>>                "if=$src_path", "of=$dst_path"]);
>>>>>            } else {
>>>>>            qemu_img_convert($drive->{file}, $newvolid, $size,
>>>>> $snapname, $sparseinit);
>>>>>
>>
>>
>> _______________________________________________
>> pve-devel mailing list
>> pve-devel@lists.proxmox.com
>> https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01  9:42 [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible Fabian Ebner
  2021-03-01  9:54 ` Stefan Reiter
@ 2021-03-01 10:23 ` Fabian Ebner
  1 sibling, 0 replies; 9+ messages in thread
From: Fabian Ebner @ 2021-03-01 10:23 UTC (permalink / raw)
  To: pve-devel

After a short off-list discussion with Thomas, we decided to first 
assert that the size is a multiple of 1024 and then simply use bs=1024.

If a new architecture with a strange-sized VARS file comes along we have 
to adapt it though.

Am 01.03.21 um 10:42 schrieb Fabian Ebner:
> Moving to Ceph is very slow when bs=1. Instead, use the biggest possible power
> of two <= 1024. At the moment our EFI image sizes are multiples of 1024, so
> just using 1024 wouldn't be a problem, but this feels more future-proof.
> 
> Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
> ---
> 
> I did not see an way for 'qemu-img dd' to use a larger blocksize while still
> specifying the exact total size if it is not a multiple of the blocksize.
> 
>   PVE/QemuServer.pm | 10 +++++++++-
>   1 file changed, 9 insertions(+), 1 deletion(-)
> 
> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
> index f401baf..e579cdf 100644
> --- a/PVE/QemuServer.pm
> +++ b/PVE/QemuServer.pm
> @@ -6991,7 +6991,15 @@ sub clone_disk {
>   		# that is given by the OVMF_VARS.fd
>   		my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>   		my $dst_path = PVE::Storage::path($storecfg, $newvolid);
> -		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=1", "count=$size",
> +
> +		# Ceph doesn't like too small blocksize, see bug #3324
> +		my $bs = 1;
> +		while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
> +		    $bs *= 2;
> +		}
> +		my $count = $size / $bs;
> +
> +		run_command(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=$bs", "count=$count",
>   		    "if=$src_path", "of=$dst_path"]);
>   	    } else {
>   		qemu_img_convert($drive->{file}, $newvolid, $size, $snapname, $sparseinit);
> 




^ permalink raw reply	[flat|nested] 9+ messages in thread

* Re: [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible
  2021-03-01 10:18       ` Dietmar Maurer
  2021-03-01 10:22         ` Fabian Ebner
@ 2021-03-02  7:11         ` Fabian Ebner
  1 sibling, 0 replies; 9+ messages in thread
From: Fabian Ebner @ 2021-03-02  7:11 UTC (permalink / raw)
  To: Dietmar Maurer, Proxmox VE development discussion

Am 01.03.21 um 11:18 schrieb Dietmar Maurer:
> 
>>>>> diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
>>>>> index f401baf..e579cdf 100644
>>>>> --- a/PVE/QemuServer.pm
>>>>> +++ b/PVE/QemuServer.pm
>>>>> @@ -6991,7 +6991,15 @@ sub clone_disk {
>>>>>            # that is given by the OVMF_VARS.fd
>>>>>            my $src_path = PVE::Storage::path($storecfg, $drive->{file});
>>>>>            my $dst_path = PVE::Storage::path($storecfg, $newvolid);
>>>>> -        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format,
>>>>> "bs=1", "count=$size",
>>>>> +
>>>>> +        # Ceph doesn't like too small blocksize, see bug #3324
>>>>> +        my $bs = 1;
>>>>> +        while ($bs < $size && $bs < 1024 && $size % $bs == 0) {
>>>>> +            $bs *= 2;
>>>>> +        }
> 
> now, $size % $bs != 0
> 
> I guess this is wrong...
> 

Sorry about the confusion yesterday. Of course you are right.

>>>>> +        my $count = $size / $bs;
>>>>> +
>>>>> +        run_command(['qemu-img', 'dd', '-n', '-O', $dst_format,
>>>>> "bs=$bs", "count=$count",
>>>>>                "if=$src_path", "of=$dst_path"]);
>>>>>            } else {
>>>>>            qemu_img_convert($drive->{file}, $newvolid, $size,
>>>>> $snapname, $sparseinit);
>>>>>
>>
>>
>> _______________________________________________
>> pve-devel mailing list
>> pve-devel@lists.proxmox.com
>> https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel




^ permalink raw reply	[flat|nested] 9+ messages in thread

end of thread, other threads:[~2021-03-02  7:12 UTC | newest]

Thread overview: 9+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2021-03-01  9:42 [pve-devel] [PATCH qemu-server] fix #3324: clone disk: use larger blocksize for EFI disk when possible Fabian Ebner
2021-03-01  9:54 ` Stefan Reiter
2021-03-01 10:06   ` Fabian Ebner
2021-03-01 10:13     ` Stefan Reiter
2021-03-01 10:18       ` Dietmar Maurer
2021-03-01 10:22         ` Fabian Ebner
2021-03-02  7:11         ` Fabian Ebner
2021-03-01 10:19       ` Fabian Ebner
2021-03-01 10:23 ` Fabian Ebner

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal