On Mon Jan 20, 2025 at 3:51 PM CET, Dominik Csapak wrote:
[..]
> +my sub get_current_node_mapping {
> + my ($mapping_config, $mapping_name) = @_;
> +
> + my $node = PVE::INotify::nodename();
> + my $devices = PVE::Mapping::PCI::get_node_mapping($mapping_config, $mapping_name, $node);
> + die "PCI device mapping not found for '$mapping_name'\n" if !$devices || !scalar($devices->@*);
> +
> + return $devices;
> +}
> +
> # returns the parsed pci config but parses the 'host' part into
> # a list if lists into the 'id' property like this:
> #
> @@ -429,8 +440,8 @@ sub parse_hostpci {
>
> if ($mapping) {
> # we have no ordinary pci id, must be a mapping
> - my $devices = PVE::Mapping::PCI::find_on_current_node($mapping);
> - die "PCI device mapping not found for '$mapping'\n" if !$devices || !scalar($devices->@*);
> + my $config = PVE::Mapping::PCI::config();
Nit: Maybe move this line into get_current_node_mapping() too, much like
is done in the previous patch for PVE::QemuServer::USB? Would be nice
from a consistency point-of-view.
> + my $devices = get_current_node_mapping($config, $mapping);
_______________________________________________
pve-devel mailing list
pve-devel@lists.proxmox.com
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel
next prev parent reply other threads:[~2025-02-11 12:45 UTC|newest]
Thread overview: 32+ messages / expand[flat|nested] mbox.gz Atom feed top
2025-01-20 14:51 [pve-devel] [PATCH guest-common/qemu-server/manager/docs v5 0/3] implement experimental vgpu live migration Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH guest-common v5 1/3] mapping: pci: check the mdev configuration on the device too Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH guest-common v5 2/3] mapping: pci: add 'live-migration-capable' flag to mappings Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH guest-common v5 3/3] mapping: remove find_on_current_node Dominik Csapak
2025-01-22 8:16 ` Dominik Csapak
2025-01-22 15:10 ` Thomas Lamprecht
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 01/11] usb: mapping: move implementation of find_on_current_node here Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 02/11] pci: " Dominik Csapak
2025-02-11 12:45 ` Christoph Heiss [this message]
2025-02-13 9:30 ` Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 03/11] pci: mapping: check mdev config against hardware Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 04/11] vm stop-cleanup: allow callers to decide error behavior Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 05/11] migrate: call vm_stop_cleanup after stopping in phase3_cleanup Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 06/11] pci: set 'enable-migration' to on for live-migration marked mapped devices Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 07/11] check_local_resources: add more info per mapped device and return as hash Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 08/11] api: enable live migration for marked mapped pci devices Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 09/11] api: include not mapped resources for running vms in migrate preconditions Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 10/11] tests: cfg2cmd: fix mdev tests Dominik Csapak
2025-01-22 15:10 ` Thomas Lamprecht
2025-01-20 14:51 ` [pve-devel] [PATCH qemu-server v5 11/11] migration: show vfio state transferred too Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH manager v5 1/5] mapping: pci: include mdev in config checks Dominik Csapak
2025-01-20 14:51 ` [pve-devel] [PATCH manager v5 2/5] bulk migrate: improve precondition checks Dominik Csapak
2025-02-11 12:50 ` Christoph Heiss
2025-01-20 14:51 ` [pve-devel] [PATCH manager v5 3/5] bulk migrate: include checks for live-migratable local resources Dominik Csapak
2025-01-20 14:52 ` [pve-devel] [PATCH manager v5 4/5] ui: adapt migration window to precondition api change Dominik Csapak
2025-01-20 14:52 ` [pve-devel] [PATCH manager v5 5/5] fix #5175: ui: allow configuring and live migration of mapped pci resources Dominik Csapak
2025-01-20 14:52 ` [pve-devel] [PATCH docs v5 1/2] qm: resource mapping: add description for `mdev` option Dominik Csapak
2025-01-20 14:52 ` [pve-devel] [PATCH docs v5 2/2] qm: resource mapping: document `live-migration-capable` setting Dominik Csapak
2025-02-11 12:57 ` [pve-devel] [PATCH guest-common/qemu-server/manager/docs v5 0/3] implement experimental vgpu live migration Christoph Heiss
2025-03-05 10:34 ` Eneko Lacunza via pve-devel
2025-03-06 11:06 ` Dominik Csapak
2025-03-06 14:42 ` Eneko Lacunza via pve-devel
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=D7PMKAGM4YFP.KL69Q8B9ZZ9F@proxmox.com \
--to=c.heiss@proxmox.com \
--cc=d.csapak@proxmox.com \
--cc=pve-devel@lists.proxmox.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal