messages from 2026-11-24 14:42:14 to 2026-11-28 15:22:53 UTC [more...]
[RFC PATCH cluster/ha-manager/qemu-server/manager/docs 00/11] fix #6314: ha: keep guests stopped that got powered off from within
2026-11-28 15:11 UTC (12+ messages)
` [RFC PATCH cluster 01/11] datacenter config: add stop-on-poweroff to the HA settings
` [RFC PATCH ha-manager 02/11] fix #6314: config: request stopped state for powered off guests
` [RFC PATCH ha-manager 03/11] lrm: do not start a service again that is about to be stopped
` [RFC PATCH ha-manager 04/11] sim: hardware: add poweroff command for services
` [RFC PATCH ha-manager 05/11] test: add test cases for stop-on-poweroff
` [RFC PATCH ha-manager 06/11] resources: add stop-on-poweroff property for virtual machines
` [RFC PATCH qemu-server 07/11] fix #6314: qm cleanup: report a guest poweroff to the HA stack
` [RFC PATCH manager 08/11] ui: dc options: add stop-on-poweroff to the HA settings
` [RFC PATCH manager 09/11] ui: ha: add stop-on-poweroff selector to the resource edit window
` [RFC PATCH docs 10/11] ha-manager: document the stop-on-poweroff setting
` [RFC PATCH docs 11/11] ha-manager: document the stop-on-poweroff property of resources
[RFC] storage: SAN LUN view treats LUNs of third-party plugins as unused, so they can be wiped
2026-11-27 18:30 UTC (3+ messages)
[PATCH manager] ui: bridge selector: add search field to the drop-down list
2026-11-27 10:00 UTC
[PATCH docs] network: ipv6: mention that all interfaces do slaac
2026-11-27 17:51 UTC (5+ messages)
` superseded: "
[PATCH docs v2] network: ipv6: mention that all interfaces do slaac
2026-11-27 17:48 UTC
[PATCH docs/manager/storage 0/4] fix #8196: lvm: add a throughput limit for discards
2026-11-27 15:44 UTC (2+ messages)
[PATCH manager 0/3] ui: lvm: encourage the use of saferemove or on-volume-remove
2026-11-27 15:32 UTC (4+ messages)
` [PATCH manager 1/3] ui: storage: SAN: add checkboxes for saferemove & on-volume-remove
` [PATCH manager 2/3] ui: lvm: display a warning when there is no cleanup
` [PATCH manager 3/3] ui: storage: SAN: "
[RFC firewall/manager/proxmox{,-firewall} v2 00/12] fix #5759: keep firewall rules up across boot and shutdown
2026-11-27 15:09 UTC (4+ messages)
` [PATCH pve-firewall v2 04/12] fix #5759: firewall: do not remove chains when host is shutting down
[PATCH-SERIES qemu-server 00/10] restore: check permissions up-front
2026-11-27 13:45 UTC (11+ messages)
` [PATCH qemu-server 01/10] restore: vma: rename variable for storage configuration
` [PATCH qemu-server 02/10] restore: skip non-main config sections
` [PATCH qemu-server 03/10] restore: introduce dedicated module
` [PATCH qemu-server 04/10] restore: move helper for cleaning up target to module
` [PATCH qemu-server 05/10] restore: move helper for parsing backup device hints "
` [PATCH qemu-server 06/10] restore: move helpers to deactivate and destroy volumes "
` [PATCH qemu-server 07/10] restore: move helpers to check identity and write config "
` [PATCH qemu-server 08/10] restore: check permissions up-front
` [PATCH qemu-server 09/10] restore: extract common helper for preparing new configuration
` [PATCH qemu-server 10/10] restore: prepare new config before modifying the target
[PATCH manager] fix #7234: ui: backup job: only select guests of the exact pool
2026-11-27 11:20 UTC
[RFC PATCH v2 network/manager/docs 00/15] sdn: add OVN zone and controller plugins
2026-11-27 10:28 UTC (16+ messages)
` [RFC PATCH v2 network 01/15] sdn: controllers: add ovn plugin
` [RFC PATCH v2 network 02/15] sdn: zones: "
` [RFC PATCH v2 network 03/15] sdn: ovn: sync the northbound database on reload
` [RFC PATCH v2 network 04/15] sdn: ovn: configure the chassis on boot and on network reload
` [RFC PATCH v2 network 05/15] sdn: ovn: add port security
` [RFC PATCH v2 network 06/15] sdn: ovn: allow overriding the port security per vnet
` [RFC PATCH v2 network 07/15] sdn: subnets: refuse gateway, snat and dhcp on ovn zones
` [RFC PATCH v2 network 08/15] sdn: ovn: support ssl connections to the databases
` [RFC PATCH v2 network 09/15] sdn: ovn: bind guest ports to the chassis of their node
` [RFC PATCH v2 manager 10/15] ui: sdn: controller selector: allow filtering by controller type
` [RFC PATCH v2 manager 11/15] ui: sdn: add ovn controller
` [RFC PATCH v2 manager 12/15] ui: sdn: add ovn zone
` [RFC PATCH v2 manager 13/15] ui: sdn: vnet: add port security for ovn zones
` [RFC PATCH v2 manager 14/15] ui: sdn: vnet: disable isolate ports "
` [RFC PATCH v2 docs 15/15] sdn: document ovn zones and controllers
[PATCH manager] ui: allow setting skip-freeze-fs in replication jobs
2026-11-27 9:47 UTC
[RFC] storage: SAN LUN view treats LUNs of third-party plugins as unused, so they can be wiped
2026-11-27 8:27 UTC
[RFC] Protect OpenTelemetry Metric Server credentials in pve-manager
2026-11-26 21:53 UTC
[PATCH test-tools 0/3] register clusters with PDM after forming them
2026-11-26 17:59 UTC (4+ messages)
` [PATCH test-tools 1/3] instance: pve client: add helper for the API certificate fingerprint
` [PATCH test-tools 2/3] instance: move the grouping of instances by cluster into a helper
` [PATCH test-tools 3/3] instance: setup: register clusters with PDM after forming them
[RFC PATCH storage/qemu-server/docs v2 0/6] offload full clone to the storage backend
2026-11-26 16:57 UTC (7+ messages)
` [RFC PATCH storage v2 1/6] storage: add asynchronous copy-offload hook for full copies
` [RFC PATCH storage v2 2/6] rbd: implement copy-offload via snapshot + clone + flatten
` [RFC PATCH storage v2 3/6] dir: implement copy-offload via reflink (FICLONE)
` [RFC PATCH storage v2 4/6] btrfs, lvmthin: implement copy-offload (atomic class)
` [RFC PATCH qemu-server v2 5/6] use storage copy-offload for full clone
` [RFC PATCH docs v2 6/6] pvesm: document copy-offload and add it to the storage capability table
[PATCH proxmox-backup 0/3] fix #8373: avoid loosing fs feature flags on mountpoints
2026-11-26 16:49 UTC (5+ messages)
` [PATCH proxmox-backup 1/3] client: pxar: refactor metadata gathering helpers into MetadataAggregator
` [PATCH proxmox-backup 2/3] client: pxar: encapsulate filesystem info in FsInfo
` [PATCH proxmox-backup 3/3] fix #8373: client: pxar: avoid losing fs feature flags on mountpoints
[PATCH proxmox/installer/docs 0/8] installer: add full-disk encryption of the system disks
2026-11-26 16:05 UTC (4+ messages)
` [PATCH installer 1/5] install: encrypt the system disks with LUKS2 or native ZFS encryption
[RFC manager/network v2 0/3] fix #5066: make generated snat rules flushable
2026-11-26 15:50 UTC (2+ messages)
` superseded: "
[PATCH manager/network v3 0/7] fix #5066: make generated snat rules flushable
2026-11-26 15:29 UTC (8+ messages)
` [PATCH network v3 1/7] style: zones: use fully qualified JSONSchema calls for standard options
` [PATCH network v3 2/7] fix #5066: zones: factor out SNAT rule generation
` [PATCH network v3 3/7] fix #5066: zones: add helper to activate prepared SNAT rules
` [PATCH network v3 4/7] fix #5066: evpn: prepare SNAT rules in temporary chain
` [PATCH network v3 5/7] fix #5066: simple zone: "
` [PATCH network v3 6/7] fix #5066: zones: add test for generating and applying SNAT rules
` [PATCH manager v3 7/7] fix #5066: network: activate prepared SDN "
[PATCH storage v5 00/13] add ZFS over NVMe/TCP storage plugin
2026-11-26 15:11 UTC (16+ messages)
` [PATCH storage v5 01/13] zfsnvme: add target state parsing and planning
` [PATCH storage v5 02/13] zfsnvme: add the target transactions
` [PATCH storage v5 03/13] zfsnvme: add storage configuration and volume methods
` [PATCH storage v5 04/13] zfsnvme: connect the nodes and register the plugin
` [PATCH storage v5 05/13] api: san luns: count zfsnvme storages as owners of their subsystem
` [PATCH storage v5 06/13] api: config: check the cluster version before the first zfsnvme storage
` [PATCH storage v5 07/13] test: zfsnvme: add configuration and volume tests
` [PATCH storage v5 08/13] test: zfsnvme: add node side tests
` [PATCH storage v5 09/13] test: zfsnvme: add an in-memory nvmet target
` [PATCH storage v5 10/13] test: zfsnvme: test the target parsers and planners
` [PATCH storage v5 11/13] test: zfsnvme: test the target flows
` [PATCH storage v5 12/13] test: zfsnvme: add a fault sweep, renderer and taint tests
` [PATCH storage v5 13/13] zfsnvme: wait up to 30 seconds for the shared storage lock
` [PATCH docs v5] storage: document ZFS over NVMe/TCP
` [PATCH manager v5] ui: storage: add ZFS over NVMe/TCP editor
[RFC] storage plugin hook for node preference in the load rebalancer
2026-11-26 14:34 UTC (3+ messages)
[PATCH e2e-tests 0/3] plans: upgrade PVE and PBS versions
2026-11-26 13:49 UTC (4+ messages)
` [PATCH e2e-tests 1/3] plans: complete: use Proxmox VE 9.3 for test instances
` [PATCH e2e-tests 2/3] plans: sdn: "
` [PATCH e2e-tests 3/3] plans: pbs: use PVE 9.3 as well as PBS 4.2 "
[PATCH common/manager/widget-toolkit 00/16] partially fix #3809: configure and monitor NTP in the node time panel
2026-11-26 13:40 UTC (17+ messages)
` [PATCH common 01/16] systemd: add helpers to get and set NTP servers
` [PATCH common 02/16] systemd: add helper to query clock synchronization status
` [PATCH common 03/16] systemd: add helpers to synchronize the clock immediately
` [PATCH common 04/16] systemd: add helper to list the current NTP sources
` [PATCH widget-toolkit 05/16] node: time: do not open the editor for the server time row
` [PATCH widget-toolkit 06/16] partially fix #3809: node: time: show and edit NTP servers if supported
` [PATCH widget-toolkit 07/16] node: time: show clock synchronization status
` [PATCH widget-toolkit 08/16] window: add reusable service log window
` [PATCH widget-toolkit 09/16] node: time: add button to open the NTP service log
` [PATCH widget-toolkit 10/16] node: time: add button to synchronize the clock immediately
` [PATCH widget-toolkit 11/16] node: time: add window listing the current NTP sources
` [PATCH manager 12/16] partially fix #3809: api: nodes: time: allow configuring NTP servers
` [PATCH manager 13/16] api: nodes: time: report clock synchronization status
` [PATCH manager 14/16] ui: node: time: use journal for the NTP service log
` [PATCH manager 15/16] api: nodes: time: add endpoint to synchronize the clock immediately
` [PATCH manager 16/16] api: nodes: time: add endpoint to list the current NTP sources
[PATCH manager 0/5] ui: improvements on translatable strings post 9.3
2026-11-26 13:16 UTC (6+ messages)
` [PATCH manager 1/5] ui: mark some strings as translatable
` [PATCH manager 2/5] ui: prefer starting actions with verbs
` [PATCH manager 3/5] ui: s/Bluestore/BlueStore/ on translatable string
` [PATCH manager 4/5] ui: Use qga's full name in translatable strings
` [PATCH manager 5/5] ui: add context to nouns which match a verb
[PATCH pve-manager 1/2] ui: storage wizard: sort storages by id
2026-11-26 10:57 UTC (2+ messages)
` [PATCH pve-manager 2/2] ui: storage wizard: ignore disabled storages when reusing a target
[PATCH common] fix #5607: json schema: describe the allowed characters of configuration IDs
2026-11-26 9:17 UTC
[PATCH proxmox-perltidy] drop blank lines directly after opening block brace
2026-11-26 8:55 UTC
[PATCH pve-storage-plugin-examples 1/1] sshfs: update to storage API 17
2026-11-25 13:18 UTC
[PATCH docs] vzdump: limit fleecing storage recommendations to local storages
2026-11-25 12:21 UTC (2+ messages)
[PATCH qemu-server] fix #6744: migrate: log the size of found local disks
2026-11-25 7:46 UTC
[PATCH firewall/proxmox{-ve-rs,-firewall} 0/7] firewall: handle guest network devices without a MAC address
2026-11-25 7:28 UTC (10+ messages)
` [PATCH proxmox-ve-rs 1/7] ve-config: guest: require the name of container network devices
` [PATCH proxmox-ve-rs 2/7] ve-config: guest: default the type of container network devices to veth
` [PATCH proxmox-ve-rs 3/7] ve-config: guest: accept network devices without a MAC address
` [PATCH proxmox-firewall 4/7] firewall: guest: handle "
` [PATCH proxmox-firewall 5/7] tests: add network devices without "
` [PATCH pve-firewall 6/7] firewall: drop the traffic of guest "
` [PATCH pve-firewall 7/7] firewall: do not generate MAC addresses for guest network devices
[PATCH manager] fix #8136: ui: user/group view: separate listed groups and users with a space
2026-11-25 7:21 UTC
[PATCH container/manager/qemu-server 0/6] persist auto-generated MAC addresses of guest network devices
2026-11-24 23:45 UTC (13+ messages)
` [PATCH pve-container 1/6] setup: do not read datacenter.cfg inside the container's root
` [PATCH pve-container 2/6] start: persist a MAC address for network devices without one
` [PATCH pve-container 3/6] restore: add missing MAC addresses of the backup config
` [PATCH qemu-server 4/6] start: persist a MAC address for network devices without one
` [PATCH qemu-server 5/6] restore: add missing MAC addresses of the backup config
` [PATCH pve-manager 6/6] ui: lxc: network: handle network devices without a MAC address
` applied: [PATCH container/manager/qemu-server 0/6] persist auto-generated MAC addresses of guest network devices
[PATCH pve-manager] ui: dc: storage: reuse icons from add wizard for tree
2026-11-24 22:52 UTC (2+ messages)
` applied: "
[PATCH widget-toolkit] ui: journal view: make filter toolbar scrollable on narrow screens
2026-11-24 22:50 UTC (2+ messages)
` applied: "
[PATCH qemu-server/pve-manager 0/2] fix #7100: allow disabling cloud-init /etc/hosts management
2026-11-24 21:26 UTC (3+ messages)
` [PATCH qemu-server 1/2] fix #7100: cloud-init: make /etc/hosts management configurable
` [PATCH pve-manager 2/2] fix #7100: ui: cloud-init: allow configuring /etc/hosts management
[PATCH installer v2] network: align VLAN interface names with the documentation
2026-11-24 18:13 UTC (2+ messages)
` applied: "
[PATCH qemu] fix windows retrim on scsi-hd: emulate GET LBA STATUS
2026-11-24 17:29 UTC
[PATCH manager/qemu-server 00/15] check the target node's CPU before live migrating a VM
2026-11-24 16:35 UTC (2+ messages)
[PATCH docs/manager/qemu-server v2 00/20] check the target node's CPU before live migrating a VM
2026-11-24 16:30 UTC (21+ messages)
` [PATCH qemu-server v2 01/20] test: migration: allow checking for warnings and errors in the log
` [PATCH qemu-server v2 02/20] migrate: block live migration of host CPU VMs between CPU vendors
` [PATCH qemu-server v2 03/20] fix #6535: migrate: warn about live migration "
` [PATCH qemu-server v2 04/20] cpu flags: factor out parsing the broadcast CPU flags of a node
` [PATCH qemu-server v2 05/20] fix #2924: migrate: block live migration of host CPU VMs to nodes lacking flags
` [PATCH qemu-server v2 06/20] migrate: warn about live migration of host CPU VMs between CPU models
` [PATCH qemu-server v2 07/20] migrate: factor out whether the running virtual CPU is kept
` [PATCH qemu-server v2 08/20] migrate: block migration if the target cannot run the virtual CPU
` [PATCH qemu-server v2 09/20] cpu flags: report invtsc support of nodes
` [PATCH qemu-server v2 10/20] helpers: add helper to query the host's TSC frequency and scaling support
` [PATCH qemu-server v2 11/20] cpu config: add hv-reenlightenment flag and set TSC frequency for it
` [PATCH qemu-server v2 12/20] migrate: block migration to nodes with incompatible TSC for re-enlightenment
` [PATCH qemu-server v2 13/20] cpu config: set TSC frequency for invtsc to allow live migration
` [PATCH qemu-server v2 14/20] migrate: factor out asserting the CPU compatibility of the target
` [PATCH qemu-server v2 15/20] api: migrate: check the CPU of the target before requesting HA migration
` [PATCH manager v2 16/20] pvestatd: broadcast host CPU information relevant for live migration
` [PATCH manager v2 17/20] ui: migrate: show why the CPU of the target node is incompatible
` [PATCH manager v2 18/20] fix #6535: ui: migrate: show CPU warnings for the target node
` [PATCH manager v2 19/20] api: nodes: migrateall: skip VMs whose CPU is incompatible with the target
` [PATCH docs v2 20/20] qm: document hv-reenlightenment, invtsc and CPU checks for migration
[PATCH manager] ui: tree: add expand/collapse all options to datacenter cmd menu
2026-11-24 16:26 UTC
[PATCH/RFC pve-manager 0/2] allow to automatically open guest panel after create wizard
2026-11-24 14:37 UTC (3+ messages)
` [PATCH pve-manager 1/2] ui: qemu create wizard: show the task progress after submitting
` [RFC PATCH pve-manager 2/2] ui: create wizards: optionally open the new guest's summary or console
page: | prev (newer) | latest
- recent:[subjects (threaded)|topics (new)|topics (active)]
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox