public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
 messages from 2026-09-23 15:09:30 to 2026-09-29 13:25:50 UTC [more...]

[PATCH pve-firewall v2] api: aliases: make 'cidr' optional when updating
 2026-09-29 13:25 UTC 

[PATCH] api: aliases: make 'cidr' optional when updating
 2026-09-29 13:23 UTC 

[PATCH pve-manager v2 0/2] ui: vm create: populate EFI and
 2026-09-29 13:16 UTC  (2+ messages)

[PATCH proxmox 0/3] minor cleanup of build.sh
 2026-09-29 12:31 UTC  (4+ messages)
` [PATCH proxmox 1/3] build.sh: remove redundant quotes in paths
` [PATCH proxmox 2/3] build.sh: replace legacy empty string check with -z
` [PATCH proxmox 3/3] build.sh: utilize CONTROL variable

[PATCH pve-network] sdn: zones: vxlan: restore the flood entries after an FRR reload
 2026-09-29  9:28 UTC 

[PATCH common/manager/proxmox-widget-toolkit/storage/storage-plugin-examples v3 00/17] GUI Support for Custom Storage Plugins
 2026-09-29  9:21 UTC  (3+ messages)

[PATCH qemu-server] fix #6907: memory: allow multi-digit host nodes with hugepages
 2026-09-28 15:26 UTC  (2+ messages)

[PATCH manager] fix #6475: ui: upload: only show the file name of the selected file
 2026-09-28 14:07 UTC  (3+ messages)

[RFC proxmox-perl-rs/qemu-server/qemu-server-rs 0/9] pci-handling rewrite (part 1)
 2026-09-28 14:06 UTC  (13+ messages)
` [PATCH pve-qemu-server-rs 1/9] add pve-qemu-server-pci crate for guest PCI address generation
` [PATCH pve-qemu-server-rs 2/9] pci: add machine abstraction and PCI bridge generation
` [PATCH pve-qemu-server-rs 3/9] pci: layout: add v2 PCI and PCIe layouts
` [PATCH proxmox-perl-rs 5/9] pve: add bindings for `pve-qemu-server-pci` crate

[PATCH storage] fix #6969: plugin: keep content directory when freeing its last file
 2026-09-28 13:37 UTC  (2+ messages)

[PATCH storage v2 0/7] add native ZFS over NVMe/TCP backend
 2026-09-28 11:53 UTC  (2+ messages)

[pve-devel] [PATCH container] add container console scrollback buffer
 2026-09-28 11:02 UTC  (3+ messages)

[PATCH installer v2] buildsys: add static version of proxmox-auto-install-assistant
 2026-09-28  9:37 UTC  (2+ messages)

[RFC qemu-server v2 0/4] fix #7282: allow (NUMA aware) vCPU pinning
 2026-09-28  8:28 UTC  (6+ messages)
` [RFC qemu-server v2 1/4] pinning: add topology discovery and config parsing

[PATCH manager 0/2] fix #6516: limit the backup job ID length on creation
 2026-09-26  7:29 UTC  (3+ messages)
` [PATCH manager 1/2] fix #6516: api: backup jobs: limit the "
` [PATCH manager 2/2] fix #6516: ui: backup job: limit the job ID length

[PATCH proxmox-acme 0/3] acme: fix missing/diverging shim helpers, tighten missing-function check
 2026-09-25 12:47 UTC  (4+ messages)
` [PATCH proxmox-acme 1/3] fix #7851: acme: add missing _mktemp and restore _dbase64 default
` [PATCH proxmox-acme 2/3] acme: add missing _url_replace function
` [PATCH proxmox-acme 3/3] tests: rewrite check-missing-functions to catch calls in substitutions

Tools for migrating Hyper-V VMs to Proxmox VE
 2026-09-25  8:33 UTC 

[PATCH manager 0/2] ui: fix memory usage percentage above 100% and its sorting
 2026-09-25  5:32 UTC  (3+ messages)
` [PATCH manager 1/2] fix #6874: ui: node selectors: sort memory usage by percentage
` [PATCH manager 2/2] fix #7224: ui: utils: show memory usage above 100% correctly

[PATCH manager] fix #7860: api: backup info: skip jobs with invalid guest selection
 2026-09-25  5:30 UTC 

[PATCH http-server 0/2] apiserver: make multipart upload parsing more RFC compliant
 2026-09-25  5:34 UTC  (3+ messages)
` [PATCH http-server 1/2] fix #6887: apiserver: accept quoted multipart boundary
` [PATCH http-server 2/2] fix #7389: apiserver: accept unquoted multipart parameter values

SPAM: [RFC PATCH 0/4] lxc: add safe OCI rootfs replacement
 2026-09-24 18:39 UTC  (3+ messages)
`  "

[PATCH 2/2] manager: add GUI support for backup export and import
 2026-09-23 12:25 UTC 

[PATCH v2 0/16] Support for custom EFI firmware
 2026-09-28  5:48 UTC  (17+ messages)
` [PATCH v2 pve-storage 1/16] plugin: add efi-firmware content type
` [PATCH v2 pve-storage 2/16] test: get_subdir: cover the "
` [PATCH v2 pve-storage 3/16] plugins: allow the efi-firmware content type on file based storages
` [PATCH v2 pve-storage 4/16] api: status: support efi-firmware in upload and download-url
` [PATCH v2 pve-storage 5/16] test: volume access: cover efi-firmware volumes
` [PATCH v2 pve-storage 6/16] test: list volumes: "
` [PATCH v2 qemu-server 07/16] config: add the efi-firmware option
` [PATCH v2 qemu-server 08/16] api: allow setting "
` [PATCH v2 qemu-server 09/16] ovmf: use a custom firmware image if configured
` [PATCH v2 qemu-server 10/16] test: efi-firmware key in VM config
` [PATCH v2 qemu-server 11/16] test: efi-firmware volumes replication
` [PATCH v2 pve-manager 12/16] ui: storage: add efi-firmware content type support
` [PATCH v2 pve-manager 13/16] ui: form: support other content types in the ISO selector
` [PATCH v2 pve-manager 14/16] ui: qemu: allow selecting a custom EFI firmware image
` [PATCH v2 pve-docs 15/16] pvesm: document the efi-firmware content type
` [PATCH v2 pve-docs 16/16] qm: document the efi-firmware VM option

[PATCH manager 0/1] ui: ceph: fix muting a health check with no expiry
 2026-09-27 14:18 UTC  (2+ messages)
` [PATCH manager] fix #8046: "

[PATCH manager 0/4] cephx: migrate keys with a monitor this cluster does not manage
 2026-09-27  0:59 UTC  (5+ messages)
` [PATCH manager 1/4] migrations: cephx: ask a monitor about itself through one route
` [PATCH manager 2/4] migrations: cephx: judge cipher support by the version a daemon runs
` [PATCH manager 3/4] migrations: cephx: rotate the monitor key with monitors we do not manage
` [PATCH manager 4/4] migrations: cephx: name the hosts keeping key copies we cannot write

[RFC cluster/manager 00/10] pmxcfs: add a change notification socket
 2026-09-25 15:18 UTC  (11+ messages)
` [PATCH pve-cluster 01/10] buildsys: add rust workspace under src/rust
` [PATCH pve-cluster 02/10] rust: notify: add change notification socket server

[PATCH pve-network] sdn: zones: vxlan: set the local tunnel address explicitly
 2026-09-25 13:40 UTC 

[PATCH-SERIES qemu-server 0/7] fix #8071: volume snapshot delete: use current drive information to fix SAVC handling
 2026-09-25 12:26 UTC  (8+ messages)
` [PATCH qemu-server 1/7] volume snapshot (delete): avoid using deprecated check_running() helper
` [PATCH qemu-server 2/7] volume snapshot delete: move getting attached device ID to caller
` [PATCH qemu-server 3/7] fix #8071: volume snapshot delete: use current drive information to fix SAVC handling
` [PATCH qemu-server 4/7] snapshot: add module for snapshot-related functionality
` [PATCH qemu-server 5/7] snapshot: use v5.36 and subroutine signatures
` [PATCH qemu-server 6/7] volume chain: blockdev delete: remove superfluous parse_volume_id() call
` [PATCH qemu-server 7/7] volume chain: blockdev delete: pass volume ID instead of drive and mark private

SPAM: [PATCH container/firewall/manager/network/qemu-server v3 00/16] handle dangling references when firewall objects go away
 2026-09-25 11:05 UTC  (18+ messages)
` [PATCH pve-firewall v3 01/16] helpers: add helpers to update firewall object references
` [PATCH pve-firewall v3 02/16] parser: do not log errors for disabled rules
` [PATCH pve-firewall v3 03/16] api: ipset: add option to update references on edit
` [PATCH pve-firewall v3 04/16] api: ipset: add option to handle dangling references on delete
` [PATCH pve-firewall v3 05/16] api: aliases: add option to update references on edit
` [PATCH pve-firewall v3 06/16] api: aliases: add option to handle dangling references on delete
` SPAM: [PATCH pve-firewall v3 07/16] firewall: tests: add tests for object reference update logic
` SPAM: [PATCH pve-network v3 08/16] apply: add option to handle dangling references on VNet deletion
` [PATCH qemu-server v3 09/16] api: destroy_vm: add option to handle dangling IPSet references
` SPAM: [PATCH pve-container v3 10/16] "
` SPAM: [PATCH pve-manager v3 11/16] ui: firewall: add common widgets for deleting and updating references
` [PATCH pve-manager v3 12/16] ui: firewall: ipset: add controls to update/delete references on edit
` [PATCH pve-manager v3 13/16] ui: firewall: aliases: "
` [PATCH pve-manager v3 14/16] ui: sdn: apply: add control for dangling IPSet references
` [PATCH pve-manager v3 15/16] ui: guest destroy: use let for non-constant variable bindings
` [PATCH pve-manager v3 16/16] ui: guest destroy: add control for dangling IPSet references

[PATCH firewall/manager v2 0/9] allow updating references when renaming/deleting firewall objects
 2026-09-25  9:44 UTC  (2+ messages)
` superseded: "

[PATCH access-control] fix #8053: auth: accept "0" as password for pam and pve realms
 2026-09-25  9:21 UTC 

[PATCH manager] fix #7623: ui: backup: only list guests of the selected pool
 2026-09-25  9:20 UTC 

[PATCH many v5 0/7] add option to prevent suggesting previously used VMIDs
 2026-09-24 16:18 UTC  (5+ messages)
` superseded: "

[PATCH many v6 00/18] add option to prevent suggesting previously used VMIDs
 2026-09-24 16:15 UTC  (19+ messages)
` [PATCH cluster v6 01/18] cluster files: add virtual-guest/used-guest-ids
` [PATCH cluster v6 02/18] datacenter config: add unique subproperty to next-id
` [PATCH cluster v6 03/18] datacenter config: next-id: add enforce subproperty
` [PATCH guest-common v6 04/18] add module to track previously used guest IDs
` [PATCH guest-common v6 05/18] tests: add tests for used guest ID tracking
` [PATCH guest-common v6 06/18] abstract config: register used guest ID when creating config
` [PATCH guest-common v6 07/18] guest id: keep used ID list below the pmxcfs file size limit
` [PATCH guest-common v6 08/18] tests: add tests for used-guest-ids max file size handling
` [PATCH guest-common v6 09/18] guest id: optionally enforce the next-id range and uniqueness
` [PATCH qemu-server v6 10/18] api: record VM ID as used on destruction and remote migration
` [PATCH qemu-server v6 11/18] api, remote migrate: exempt existing VMs from next-id enforcement
` [PATCH container v6 12/18] api: record CT ID as used on destruction and remote migration
` [PATCH container v6 13/18] api, migrate: exempt existing CTs from next-id enforcement
` [PATCH manager v6 14/18] fix #4369: api: optionally only suggest unique IDs
` [PATCH manager v6 15/18] ui: dc options: rename VMID to guest ID
` [PATCH manager v6 16/18] fix #4369: ui: dc options: add option for unique VM/CT IDs
` [PATCH manager v6 17/18] api: nextid: reject IDs forbidden by next-id enforcement
` [PATCH manager v6 18/18] ui: dc options: add option to enforce next free guest ID settings

[PATCH 0/7] SEV: Expose chip ID and reported TCB versions
 2026-09-24 14:14 UTC  (8+ messages)
` [PATCH pve-common 1/7] procfs: read CPU model and stepping from cpuinfo
` [PATCH qemu-server 2/7] sev: Detect SEV-
` [PATCH qemu-server 3/7] sev: Expose chip ID and reported TCB versions
` [PATCH qemu-server 4/7] api: add endpoint for SEV attestation data
` [PATCH pve-manager 5/7] api: register SEV capabilities endpoint
` [PATCH pve-docs 6/7] qm: Describe ASIDs for SEV
` [PATCH pve-docs 7/7] sev: Describe VCEK retieval

[PATCH pve-storage] esxi plugin: keep uuid inside vm the same as in esxi
 2026-09-24 12:14 UTC  (2+ messages)

[PATCH cluster/manager v5 0/2] Configurable window titles for nodes
 2026-09-24 12:01 UTC  (5+ messages)
` [PATCH cluster v5 1/2] fix #5475: configurable window title
` [PATCH manager v5 2/2] "

[PATCH cluster/manager v4 0/2] Configurable window titles for nodes
 2026-09-24  9:54 UTC  (2+ messages)
` superseded: "

[PATCH pve-storage, pve-manager v1 00/54] Fix #2884: Implement Subdirectory Scanning for Dir-Based Storage Types
 2026-09-24  9:43 UTC  (2+ messages)
` superseded: "

[PATCH installer 0/3] clean up old, unused files
 2026-09-24  9:41 UTC  (2+ messages)

[PATCH proxmox] installer-types: align documentation of hdsize for btrfs with lvm & zfs
 2026-09-24  9:33 UTC  (2+ messages)

[RFC] Native ZFS over NVMe/TCP storage backend for Proxmox VE
 2026-09-24  9:26 UTC  (7+ messages)

[PATCH many 00/29] notifications: add nested match expressions
 2026-09-24  8:30 UTC  (5+ messages)
` [PATCH proxmox-perl-rs 24/29] notify: opt into 'legacy-matchers' feature in proxmox-notify

[RFC pve-container 1/1] mountpoint backup: allow changing backup flag at runtime
 2026-09-24  6:36 UTC  (5+ messages)

[PATCH cluster/access-control/manager/docs/proxmox 0/9] fix #7805: add a datacenter-wide API token policy
 2026-09-23 20:59 UTC  (10+ messages)
` [PATCH cluster 1/9] datacenter config: add token-policy option
` [PATCH access-control 2/9] fix #7805: api: token: enforce datacenter token policy
` [PATCH docs 3/9] user management: document the API "
` [PATCH manager 4/9] ui: token edit: only submit the expiration date when changed
` [PATCH manager 5/9] api: cluster options: return token-policy without Sys.Audit
` [PATCH manager 6/9] ui: dc options: allow editing the API token policy
` [PATCH manager 7/9] ui: token edit: adapt to the datacenter "
` [PATCH proxmox 8/9] access-control: add API token policy type with expiry checks
` [PATCH proxmox 9/9] access-control: enforce token policy on token create and update

[PATCH proxmox-firewall] nftables: move protocol match rendering into the lib
 2026-09-23 19:15 UTC  (2+ messages)
` applied: "

[PATCH proxmox-firewall] nftables: build without the config extension
 2026-09-23 19:15 UTC  (2+ messages)
` applied: "

[PATCH proxmox-firewall] nftables: add support for mark-keyed verdict maps
 2026-09-23 19:15 UTC  (2+ messages)
` applied: "

[PATCH e2e-tests 1/1] debian: storage-plugin: add libguestfs-tools as recommended dependency
 2026-09-23 19:11 UTC  (2+ messages)
` applied: "

[PATCH test-tools 0/4] remove PDM submodule
 2026-09-23 19:10 UTC  (2+ messages)
` applied: "

[PATCH manager/storage v2 00/50] Fix #2884: Implement Subdirectory Scanning for Dir-Based Storage Types
 2026-09-23 15:16 UTC  (31+ messages)
` [PATCH pve-storage v2 21/50] test: guest import: add tests for PVE::GuestImport
` [PATCH pve-storage v2 22/50] tree-wide: introduce parsing module and replace usages of ISO_EXT_RE_0
` [PATCH pve-storage v2 23/50] common: test: set up parser testing code, add tests for 'iso' vtype
` [PATCH pve-storage v2 24/50] tree-wide: replace usages of VZTMPL_EXT_RE_1 with parsing functions
` [PATCH pve-storage v2 25/50] tree-wide: replace usages of BACKUP_EXT_RE_2 "
` [PATCH pve-storage v2 26/50] tree-wide: replace usages of inline regexes for snippets with parsers
` [PATCH pve-storage v2 27/50] tree-wide: partially replace usages of regexes for 'import' vtype
` [PATCH pve-storage v2 28/50] tree-wide: replace remaining "
` [PATCH pve-storage v2 29/50] tree-wide: simplify recently refactored parsing logic
` [PATCH pve-storage v2 30/50] test: list volumes: reorganize and modernize test running code
` [PATCH pve-storage v2 31/50] test: list volumes: fix broken test checking for vmlist modifications
` [PATCH pve-storage v2 32/50] test: list volumes: introduce new format for test cases
` [PATCH pve-storage v2 33/50] test: list volumes: remove legacy code and migrate cases to new format
` [PATCH pve-storage v2 34/50] plugin: do not return volumes of undeclared content types anymore
` [PATCH pve-storage v2 35/50] plugin: correct comment in get_subdir_files helper
` [PATCH pve-storage v2 36/50] test: parse volname: modernize code
` [PATCH pve-storage v2 37/50] test: parse volname: adapt tests regarding 'import' volume type
` [PATCH pve-storage v2 38/50] test: parse volname: move VM disk test creation into separate block
` [PATCH pve-storage v2 39/50] test: parse volname: move backup file test creation into sep. block
` [PATCH pve-storage v2 40/50] test: parse volname: parameterize test case creation for some vtypes
` [PATCH pve-storage v2 41/50] test: volume id: modernize code
` [PATCH pve-storage v2 42/50] test: volume id: rename 'volname' test case parameter to 'file'
` [PATCH pve-storage v2 43/50] test: filesystem path: modernize code
` [PATCH pve-storage v2 44/50] fix #2884: implement nested subdir scanning and support 'iso' vtype
  ` [PATCH pve-storage v2 45/50] fix #2884: support nested subdir scanning for 'vztmpl' volume type
  ` [PATCH pve-storage v2 46/50] fix #2884: support nested subdir scanning for 'snippets' vtype
  ` [PATCH pve-storage v2 47/50] test: add more tests for 'import' vtype & guard against nested subdirs
  ` [PATCH pve-storage v2 48/50] test: add tests guarding against subdir scanning for vtypes
  ` [PATCH pve-manager v2 49/50] fix #2884: ui: storage: add field for 'max-scan-depth' property
  ` [PATCH pve-manager v2 50/50] pve8to9: use helper from common storage module to get vtype subdir


This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal