public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
[pve-devel] [PATCH docs/firewall/manager/network/proxmox{-ve-rs, -firewall} v4 00/18] add forward chain firewalling for hosts and vnets
 2024-11-15 12:11 UTC  (10+ messages)
` [pve-devel] [PATCH proxmox-ve-rs v4 01/18] firewall: add forward direction
` [pve-devel] [PATCH proxmox-ve-rs v4 02/18] firewall: add bridge firewall config parser
` [pve-devel] [PATCH proxmox-ve-rs v4 03/18] config: firewall: add tests for interface and directions
` [pve-devel] [PATCH proxmox-ve-rs v4 04/18] host: add struct representing bridge names
` [pve-devel] [PATCH proxmox-firewall v4 05/18] nftables: derive additional traits for nftables types
` [pve-devel] [PATCH proxmox-firewall v4 06/18] sdn: add support for loading vnet-level firewall config
` [pve-devel] [PATCH proxmox-firewall v4 08/18] use std::mem::take over drain()
` [pve-devel] [PATCH pve-firewall v4 11/18] firewall: move to arrow syntax for calling functions
` [pve-devel] [PATCH pve-network v4 17/18] firewall: add endpoints for vnet-level firewall

[pve-devel] [PATCH docs/firewall/manager/proxmox{-firewall, -perl-rs} v4 0/9] autogenerate ipsets for sdn objects
 2024-11-15 12:09 UTC  (9+ messages)
` [pve-devel] [PATCH proxmox-firewall v4 2/9] config: tests: add support for loading sdn and ipam config
` [pve-devel] [PATCH proxmox-firewall v4 3/9] ipsets: autogenerate ipsets for vnets and ipam
` [pve-devel] [PATCH pve-firewall v4 4/9] add support for loading sdn firewall configuration
` [pve-devel] [PATCH pve-firewall v4 5/9] nftables: make is_nftables check flag file instead of config
` [pve-devel] [PATCH pve-firewall v4 6/9] api: load sdn ipsets
` [pve-devel] [PATCH proxmox-perl-rs v4 7/9] add PVE::RS::Firewall::SDN module
` [pve-devel] [PATCH pve-manager v4 8/9] firewall: add sdn scope to IPRefSelector
` [pve-devel] [PATCH pve-docs v4 9/9] sdn: add documentation for firewall integration

[pve-devel] [PATCH storage/qemu-server/manager v5] implement ova/ovf import for file based storages
 2024-11-15 11:47 UTC  (32+ messages)
` [pve-devel] [PATCH storage v5 01/12] copy OVF.pm from qemu-server
` [pve-devel] [PATCH storage v5 02/12] plugin: dir: implement import content type
` [pve-devel] [PATCH storage v5 03/12] plugin: dir: handle ova files for import
` [pve-devel] [PATCH storage v5 04/12] ovf: improve and simplify path checking code
` [pve-devel] [PATCH storage v5 05/12] ovf: implement parsing the ostype
` [pve-devel] [PATCH storage v5 06/12] ovf: implement parsing out firmware type
` [pve-devel] [PATCH storage v5 07/12] ovf: implement rudimentary boot order
` [pve-devel] [PATCH storage v5 08/12] ovf: implement parsing nics
` [pve-devel] [PATCH storage v5 09/12] api: allow ova upload/download
` [pve-devel] [PATCH storage v5 10/12] plugin: enable import for nfs/btrfs/cifs/cephfs/glusterfs
` [pve-devel] [PATCH storage v5 11/12] add 'import' content type to 'check_volume_access'
` [pve-devel] [PATCH storage v5 12/12] plugin: file_size_info: don't ignore base path with whitespace
` [pve-devel] [PATCH qemu-server v5 1/4] api: delete unused OVF.pm
` [pve-devel] [PATCH qemu-server v5 2/4] use OVF from Storage
` [pve-devel] [PATCH qemu-server v5 3/4] api: create: implement extracting disks when needed for import-from
` [pve-devel] [PATCH qemu-server v5 4/4] api: create: add 'import-extraction-storage' parameter
` [pve-devel] [PATCH manager v5 1/9] ui: fix special 'import' icon for non-esxi storages
` [pve-devel] [PATCH manager v5 2/9] ui: guest import: add ova-needs-extracting warning text
` [pve-devel] [PATCH manager v5 3/9] ui: enable import content type for relevant storages
` [pve-devel] [PATCH manager v5 4/9] ui: enable upload/download/remove buttons for 'import' type storages
` [pve-devel] [PATCH manager v5 5/9] ui: disable 'import' button for non importable formats
` [pve-devel] [PATCH manager v5 6/9] ui: import: improve rendering of volume names
` [pve-devel] [PATCH manager v5 7/9] ui: guest import: add storage selector for ova extraction storage
` [pve-devel] [PATCH manager v5 8/9] ui: guest import: change icon/text for non-esxi import storage
` [pve-devel] [PATCH manager v5 9/9] ui: import: show size for dir-based storages

[pve-devel] [PATCH docs/firewall/manager/network/proxmox{-ve-rs, -firewall} v3 00/18] add forward chain firewalling for hosts and vnets
 2024-11-15 11:25 UTC  (6+ messages)
` [pve-devel] [PATCH pve-docs v3 18/18] firewall: add documentation for forward direction

[pve-devel] [PATCH docs/firewall/manager/proxmox{-ve-rs, -firewall, -perl-rs} v3 00/24] autogenerate ipsets for sdn objects
 2024-11-15 11:17 UTC  (5+ messages)
` [pve-devel] [PATCH proxmox-ve-rs v3 16/24] tests: add ipam tests
  ` [pve-devel] partially-applied-series: "

[pve-devel] [PATCH installer] auto-installer: fix: add default value for partition-label
 2024-11-15 10:32 UTC 

[pve-devel] [PATCH v2 storage/guest-common/qemu-server 0/3] harden import of file-based volumes
 2024-11-15 10:16 UTC  (12+ messages)
` [pve-devel] [PATCH v2 storage 1/1] file_size_info: implement untrusted mode
  ` [pve-devel] applied: "
` [pve-devel] [PATCH v2 qemu-server 1/1] disk import: add additional safeguards for imported image files

[pve-devel] [RFC PATCH installer 2/5] fix #5579: first-boot: add initial service packaging
 2024-11-15 10:10 UTC 

[pve-devel] [PATCH qemu-server] fix #3588: helper: consider NIC count for config-specific timeout
 2024-11-15 10:00 UTC 

[pve-devel] [RFC PATCH installer 0/5] fix #5579: allow specifying optional first-boot script
 2024-11-15  9:49 UTC  (13+ messages)
` [pve-devel] [RFC PATCH installer 1/5] common: add function for issuing HTTP GET requests
  ` [pve-devel] applied: "
` [pve-devel] [RFC PATCH installer 2/5] fix #5579: first-boot: add initial service packaging
` [pve-devel] [RFC PATCH installer 3/5] fix #5579: auto-install-assistant: enable baking in first-boot script
` [pve-devel] [RFC PATCH installer 4/5] fix #5579: auto-installer: add optional first-boot hook script
` [pve-devel] [RFC PATCH installer 5/5] fix #5579: install: copy over `proxmox-first-boot` script if present

[pve-devel] [PATCH 0/2] Allow four-octet MAC perfixes
 2024-11-15  8:49 UTC  (2+ messages)
` [pve-devel] [PATCH] fix: allow four-octet MAC prefixes in Web UI validation

[pve-devel] [PATCH manager] ui: tree: show tooltips for all entries that have sensible information
 2024-11-15  7:08 UTC  (4+ messages)
` [pve-devel] applied: "

[pve-devel] applied: [PATCH installer] auto-install: rename 'posthook' to 'post-installation-webhook'
 2024-11-14 20:56 UTC 

[pve-devel] [PATCH installer] fetch-answer: add `$fetchinfo` meta-field to HTTP POST payload
 2024-11-14 20:05 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH installer v3 0/2] assistant: clean up glob patterns & regexes
 2024-11-14 19:53 UTC  (4+ messages)
` [pve-devel] [PATCH installer v3 1/2] tree-wide: run rustfmt, fix clippy warnings
` [pve-devel] [PATCH installer v3 2/2] assistant: avoid regex for simple prefix matching
` [pve-devel] applied: [PATCH installer v3 0/2] assistant: clean up glob patterns & regexes

[pve-devel] [PATCH-SERIES qemu/common/storage/qemu-server/container/manager v4 00/27] backup provider API
 2024-11-14 19:46 UTC  (31+ messages)
` [pve-devel] [PATCH qemu v4 01/27] PVE backup: add target ID in backup state
` [pve-devel] [PATCH qemu v4 02/27] PVE backup: get device info: allow caller to specify filter for which devices use fleecing
` [pve-devel] [PATCH qemu v4 03/27] PVE backup: implement backup access setup and teardown API for external providers
` [pve-devel] [PATCH qemu v4 04/27] PVE backup: implement bitmap support for external backup access
` [pve-devel] [PATCH common v4 05/27] test: lock file: get rid of END block that made test always pass
  ` [pve-devel] applied: "
` [pve-devel] [PATCH common v4 06/27] tools: run fork: allow running code in parent after fork
  ` [pve-devel] applied: "
` [pve-devel] [PATCH common v4 07/27] test: have lock file test use run_fork() helper
  ` [pve-devel] applied: "
` [pve-devel] [PATCH storage v4 08/27] add storage_has_feature() helper function
` [pve-devel] [PATCH storage v4 09/27] plugin: introduce new_backup_provider() method
` [pve-devel] [PATCH storage v4 10/27] extract backup config: delegate to backup provider for storages that support it
` [pve-devel] [POC storage v4 11/27] add backup provider example
` [pve-devel] [POC storage v4 12/27] WIP Borg plugin
` [pve-devel] [PATCH qemu-server v4 13/27] backup: keep track of block-node size for fleecing
` [pve-devel] [PATCH qemu-server v4 14/27] module config: load nbd module at boot
` [pve-devel] [PATCH qemu-server v4 15/27] backup: allow adding fleecing images also for EFI and TPM
` [pve-devel] [PATCH qemu-server v4 16/27] backup: implement backup for external providers
` [pve-devel] [PATCH qemu-server v4 17/27] backup: implement restore "
` [pve-devel] [PATCH qemu-server v4 18/27] backup restore: external: hardening check for untrusted source image
` [pve-devel] [PATCH container v4 19/27] add LXC::Namespaces module
` [pve-devel] [PATCH container v4 20/27] backup: implement backup for external providers
` [pve-devel] [PATCH container v4 21/27] backup: implement restore "
` [pve-devel] [PATCH container v4 22/27] external restore: don't use 'one-file-system' tar flag when restoring from a directory
` [pve-devel] [PATCH container v4 23/27] create: factor out compression option helper
` [pve-devel] [PATCH container v4 24/27] restore tar archive: check potentially untrusted archive
` [pve-devel] [PATCH container v4 25/27] api: add early check against restoring privileged container from external source
` [pve-devel] [PATCH manager v4 26/27] ui: backup: also check for backup subtype to classify archive
` [pve-devel] [PATCH manager v4 27/27] backup: implement backup for external providers

[pve-devel] [RFC ifupdown2] d/maintscripts: use postinst arguments to determine first install
 2024-11-14 17:40 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH] fix #5869: d/postinst: do not fail if ifreload fails on first install
 2024-11-14 17:37 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH pve-network 0/7] add dhcp support for all zones
 2024-11-14 10:29 UTC  (4+ messages)

[pve-devel] [PATCH storage] dirplugin: fix #3986: check for trailing slashes
 2024-11-14  9:41 UTC  (3+ messages)

[pve-devel] [PATCH v3 pve-common 0/5] Section Config: Documentation & Code Cleanup
 2024-11-14  8:37 UTC  (3+ messages)
` [pve-devel] partially-applied-series: "

[pve-devel] [PATCH pve-storage] qcow2 format: enable subcluster allocation by default
 2024-11-14  8:31 UTC  (3+ messages)

[pve-devel] [PATCH docs] fix invonking typo
 2024-11-13 15:41 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH docs] installation: document advanced btrfs options
 2024-11-13 15:40 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH manager v3] ui: acme: switch cluster view items over to those from widget-toolkit
 2024-11-13 14:36 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH manager v2] api/ui: include the node ha status in resources call and show as icon
 2024-11-13 14:36 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH SERIES openid/access-control/docs/manager] fix #4411: add support for openid groups
 2024-11-13 14:08 UTC  (7+ messages)
` [pve-devel] [PATCH openid 1/1] fix #4411: openid: add library code for openid groups support
` [pve-devel] [PATCH access-control 1/1] fix #4411: openid: add logic "

[pve-devel] [PATCH v2 manager] ui: acme: switch cluster view items over to those from widget-toolkit
 2024-11-13 13:29 UTC  (3+ messages)

[pve-devel] [PATCH cluster/qemu-server/container 0/1] fix: #5266 - RRD cleanup when pruning
 2024-11-13 13:18 UTC  (3+ messages)
` [pve-devel] [PATCH cluster/qemu-server/container 1/1] add purge_rrd_data sub

[pve-devel] [PATCH openid 0/1] Make OIDC userinfo endpoint optional
 2024-11-13 12:55 UTC  (4+ messages)
` [pve-devel] [PATCH openid 1/1] fix #4234: openid: make userinfo request optional

[pve-devel] [RFC qemu/common/storage/qemu-server/container/manager v3 00/34] backup provider API
 2024-11-13 12:03 UTC  (28+ messages)
` [pve-devel] [RFC qemu v3 06/34] PVE backup: add target ID in backup state
` [pve-devel] [RFC common v3 10/34] env: add module with helpers to run a Perl subroutine in a user namespace
` [pve-devel] [POC storage v3 14/34] add backup provider example
` [pve-devel] [POC storage v3 15/34] WIP Borg plugin
` [pve-devel] [RFC qemu-server v3 21/34] backup: implement backup for external providers
` [pve-devel] [PATCH container v3 25/34] create: add missing include of PVE::Storage::Plugin
  ` [pve-devel] applied: "
` [pve-devel] [RFC container v3 27/34] create: factor out tar restore command helper
  ` [pve-devel] applied: "
` [pve-devel] [RFC container v3 28/34] backup: implement restore for external providers
` [pve-devel] partially-applied: [RFC qemu/common/storage/qemu-server/container/manager v3 00/34] backup provider API

[pve-devel] [RFC PATCH manager] api/ui: include the node ha status in resources call and show as icon
 2024-11-13 11:39 UTC  (7+ messages)

[pve-devel] [PATCH SERIES manager/http-server/docs] fix #5699: add support for real IP
 2024-11-13 11:36 UTC  (5+ messages)
` [pve-devel] [PATCH docs 1/1] fix #5699: pveproxy: add docs for real IP support
` [pve-devel] [PATCH http-server 1/1] fix #5699: pveproxy: add library methods "

[pve-devel] [PATCH installer v2 0/4] assistant: clean up glob patterns & regexes
 2024-11-12 19:55 UTC  (3+ messages)
` [pve-devel] [PATCH installer v2 3/4] assistant: pre-compile ignored block device patterns
  ` [pve-devel] applied: "

[pve-devel] [PATCH manager 0/3] Use Autoscaler instead of Autoscale on user-facing strings
 2024-11-12 19:35 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH] patches: upstream: python3.12 compat
 2024-11-12 19:06 UTC 

[pve-devel] [PATCH widget-toolkit 0/5] improve webhook edit window
 2024-11-12 17:04 UTC  (7+ messages)
` [pve-devel] [PATCH widget-toolkit 1/5] webhook edit: improve layout and component hierarchy
` [pve-devel] [PATCH widget-toolkit 2/5] webhook edit: make items config not static
` [pve-devel] [PATCH widget-toolkit 3/5] webhook edit: use type in add button text
` [pve-devel] [PATCH widget-toolkit 4/5] webhook edit: add emptytext to key-value fields
` [pve-devel] [PATCH widget-toolkit 5/5] webhook edit: display validity for added key/value fields
` [pve-devel] applied-series: [PATCH widget-toolkit 0/5] improve webhook edit window

[pve-devel] [PATCH pve-common v2 1/4] tap_plug: add support for bridge port isolation
 2024-11-12 16:20 UTC  (5+ messages)
` [pve-devel] [PATCH pve-manager v2 2/4] sdn: vnet: add isolate-ports option
` [pve-devel] [PATCH pve-network v2 3/4] vnets : add ports isolation
` [pve-devel] [PATCH pve-docs v2 4/4] sdn: add documentation for isolated ports option
` [pve-devel] applied: [PATCH pve-common v2 1/4] tap_plug: add support for bridge port isolation

[pve-devel] [PATCH installer v2] post-hook: add `$hook` field describing document schema version
 2024-11-12 15:54 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH manager 1/3] ui: resource tree: fix order of types
 2024-11-12 15:04 UTC  (4+ messages)
` [pve-devel] [PATCH manager 3/3] ui: resource tree: show nodes/storages in pool/tag view by default

[pve-devel] [PATCH novnc v2 1/3] upgrade noVNC and patches to 1.5.0
 2024-11-12 15:04 UTC  (6+ messages)
` [pve-devel] [PATCH novnc v2 2/3] add BUILDDIR to clean make target
` [pve-devel] [PATCH novnc v2 3/3] bump version to 1.5.0-1
  ` [pve-devel] applied: "
` [pve-devel] applied: [PATCH novnc v2 1/3] upgrade noVNC and patches to 1.5.0

page:  |  | latest

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal