public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
[pve-devel] [PATCH v4 qemu-server, container, docs 0/12] migration: don't scan all storages, fail on aliases
 2023-06-16 12:16 UTC  (14+ messages)
` [pve-devel] [PATCH v4 qemu-server 1/12] migration: only migrate disks used by the guest
` [pve-devel] [PATCH v4 qemu-server 2/12] qemuserver: foreach_volid: include pending volumes
` [pve-devel] [PATCH v4 qemu-server 3/12] qemuserver: foreach_volid: always include pending disks
` [pve-devel] [PATCH v4 qemu-server 4/12] qemuserver: foreach_volid: test regular config last
` [pve-devel] [PATCH v4 qemu-server 5/12] migration: add target_storage_check_available
` [pve-devel] [PATCH v4 qemu-server 6/12] migration: scan_local_volumes: adapt refs handling
` [pve-devel] [PATCH v4 qemu-server 7/12] tests: add migration test for pending disk
` [pve-devel] [PATCH v4 qemu-server 8/12] migration: fail when aliased volume is detected
` [pve-devel] [PATCH v4 qemu-server 9/12] tests: add migration alias check
` [pve-devel] [PATCH v4 container 10/12] migration: only migrate volumes used by the guest
` [pve-devel] [PATCH v4 container 11/12] migration: fail when aliased volume is detected
` [pve-devel] [PATCH v4 docs 12/12] storage: add hint to avoid storage aliasing

[pve-devel] [PATCH-SERIES cluster/(ha-)manager] allow node HA shutdown policy override
 2023-06-16 11:33 UTC  (10+ messages)
` [pve-devel] [PATCH cluster 1/1] datacenter config: turn shutdown policy into a standard option
` [pve-devel] [PATCH ha-manager 1/7] lrm service: add runtime directory
` [pve-devel] [RFC ha-manager 2/7] lrm service: move PID file to service's "
` [pve-devel] [PATCH ha-manager 3/7] pve2 env: get shutdown policy override set by node's shutdown API endpoint
` [pve-devel] [PATCH ha-manager 4/7] lrm: honor "
` [pve-devel] [RFC ha-manager 5/7] pve2 env: validate shutdown policy from override file
` [pve-devel] [PATCH ha-manager 6/7] sim env: add support for datacenter config overrides
` [pve-devel] [PATCH ha-manager 7/7] tests: add test for shutdown policy override
` [pve-devel] [PATCH manager 1/1] api: nodes: allow setting HA shutdown policy during shutdown/reboot

[pve-devel] [PATCH installer 0/2] Close app gracefully
 2023-06-16 10:57 UTC  (3+ messages)
` [pve-devel] [PATCH installer 1/2] exit process gracefully
` [pve-devel] [PATCH installer 2/2] stop main loop when closing the main window

[pve-devel] [PATCH common] schema: explicitly set min/max for vmid option
 2023-06-16 10:40 UTC  (4+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH pve-docs v6] update the PCI(e) docs
 2023-06-16 10:37 UTC 

[pve-devel] [PATCH pve-manager 0/2] ui: fix #3760: change units of ram/swap
 2023-06-16  9:54 UTC  (3+ messages)
` [pve-devel] [PATCH pve-manager 1/2] ui: fix #3760: change unit of memory of a VM
` [pve-devel] [PATCH pve-manager 2/2] ui: fix: change units of memory/swap for containers

[pve-devel] [PATCH qemu-server/manger/docs v6] cluster mapping
 2023-06-16  9:27 UTC  (29+ messages)
` [pve-devel] [PATCH qemu-server v6 1/6] enable cluster mapped USB devices for guests
` [pve-devel] [PATCH qemu-server v6 2/6] enable cluster mapped PCI "
` [pve-devel] [PATCH qemu-server v6 3/6] check_local_resources: extend for mapped resources
` [pve-devel] [PATCH qemu-server v6 4/6] api: migrate preconditions: use new check_local_resources info
` [pve-devel] [PATCH qemu-server v6 5/6] migration: check for mapped resources
` [pve-devel] [PATCH qemu-server v6 6/6] add test for mapped pci devices
` [pve-devel] [PATCH manager v6 01/15] pvesh: fix parameters for proxyto_callback
  ` [pve-devel] applied: "
` [pve-devel] [PATCH manager v6 02/15] api: add resource map api endpoints for PCI and USB
` [pve-devel] [PATCH manager v6 03/15] ui: parser: add helper for lists of property strings
` [pve-devel] [PATCH manager v6 04/15] ui: form/USBSelector: make it more flexible with nodename
` [pve-devel] [PATCH manager v6 05/15] ui: form: add PCIMapSelector
` [pve-devel] [PATCH manager v6 06/15] ui: form: add USBMapSelector
` [pve-devel] [PATCH manager v6 07/15] ui: qemu/PCIEdit: rework panel to add a mapped configuration
` [pve-devel] [PATCH manager v6 08/15] ui: qemu/USBEdit: add 'mapped' device case
` [pve-devel] [PATCH manager v6 09/15] ui: form: add MultiPCISelector
` [pve-devel] [PATCH manager v6 10/15] ui: add edit window for pci mappings
` [pve-devel] [PATCH manager v6 11/15] ui: add edit window for usb mappings
` [pve-devel] [PATCH manager v6 12/15] ui: add ResourceMapTree
` [pve-devel] [PATCH manager v6 13/15] ui: allow configuring pci and usb mapping
` [pve-devel] [PATCH manager v6 14/15] ui: window/Migrate: allow mapped devices
` [pve-devel] [PATCH manager v6 15/15] ui: improve permission handling for hardware
` [pve-devel] [PATCH docs v6 1/1] qemu: add documentation about cluster device mapping

[pve-devel] [PATCH proxmox-backup 0/3] file-restore: set arc limits correctly
 2023-06-15 16:11 UTC  (5+ messages)
` [pve-devel] [PATCH proxmox-backup 1/3] file-restore: add zfs. prefix to arc_min/max settings
` [pve-devel] [PATCH proxmox-backup 2/3] file-restore: set zfs_arc_min to current minimum of 32M
` [pve-devel] [PATCH proxmox-backup 3/3] file-restore: set loglevel considering PBS_QEMU_DEBUG
` [pve-devel] applied: [PATCH proxmox-backup 0/3] file-restore: set arc limits correctly

[pve-devel] [PATCH manager stable-7] pve7to8: content-dirs check: skip paths that cannot be resolved
 2023-06-15 14:47 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH v2 manager/container/guest-common 0/4] fix #3069: add pbs-entries-max to vzdump.conf
 2023-06-15 14:14 UTC  (5+ messages)
` [pve-devel] [PATCH v2 manager 1/4] api: backup: refactor backup permission check
` [pve-devel] [PATCH v2 manager 2/4] api: backup: add 'pbs-entries-max' to permission check & config
` [pve-devel] [PATCH v2 container 3/4]: add 'pbs-entries-max' parameter
` [pve-devel] [PATCH v2 guest-common 4/4] vzdump: schema: add 'pbs-entries-max' property

[pve-devel] [PATCH common v2] fix #4778: fix boolean type check for json parameters over the api
 2023-06-15 13:00 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH pve-storage/pve-manager v3 0/4] fix #623: show isos/vztmpl/snippets in subdirs
 2023-06-15 12:56 UTC  (6+ messages)
` [pve-devel] [PATCH pve-storage v3 1/3] recursively go through subdirs to find files
` [pve-devel] [PATCH pve-storage v3 2/3] add `subdir-depth` option to filesystems
` [pve-devel] [PATCH pve-storage v3 3/3] update test for recursive subdir search
` [pve-devel] [PATCH pve-manager v3]ui: add field to set subdir-depth in web interface

[pve-devel] [PATCH RFC common] fix #4778: fix boolean type check for json parameters over the api
 2023-06-15 12:43 UTC  (5+ messages)

[pve-devel] [PATCH storage] content-dirs check: silently skip paths that cannot be resolved
 2023-06-15 12:19 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH v2 storage] api: config: add/update storage: check for type mismatch first
 2023-06-15 12:19 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH qemu 1/2] regenerate patches
 2023-06-15 12:15 UTC  (3+ messages)
` [pve-devel] [PATCH qemu 2/2] fix checks for drive mirror with bitmap
` [pve-devel] applied-series: [PATCH qemu 1/2] regenerate patches

[pve-devel] [PATCH installer 0/4] Drop deprecated GTK 3 methods
 2023-06-15 12:15 UTC  (5+ messages)
` [pve-devel] [PATCH installer 1/4] stop using Gtk3::Misc->set_alignment
` [pve-devel] [PATCH installer 2/4] stop using Gtk3::HBox and Gtk3::VBox
` [pve-devel] [PATCH installer 3/4] stop using Gtk3::HSeparator
` [pve-devel] [PATCH installer 4/4] stop using Gtk3::Window->set_has_resize_grip

[pve-devel] [PATCH qemu-server/novnc/manager/docs v9 0/5] Feature VNC-Clipboard
 2023-06-15 12:11 UTC  (2+ messages)

[pve-devel] [PATCH v2 container manager] Show dynamic container IPs in GUI
 2023-06-15  9:43 UTC  (4+ messages)
` [pve-devel] [PATCH v2 container] api: network: get interfaces from containers
` [pve-devel] [PATCH v2 manager 1/2] lxc: show dynamically assigned IPs in network tab
` [pve-devel] [PATCH v2 manager 2/2] lxc: show IPs in summary view

[pve-devel] [PATCH manager] ui: fix height 'extra cpu flags' field in create wizard
 2023-06-15  8:10 UTC  (2+ messages)

[pve-devel] [PATCH v2 firewall manager] firewall: introduce scoping for ipsets/aliases
 2023-06-15  7:42 UTC  (6+ messages)
` [pve-devel] [PATCH v2 firewall 1/2] api: fix scoping for ipset endpoint
` [pve-devel] [PATCH v2 firewall 2/2] fix #4556: api: return scoped IPSets and aliases
` [pve-devel] [PATCH v2 manager] firewall: add scope field to IPRefSelector
` [pve-devel] applied-series: [PATCH v2 firewall manager] firewall: introduce scoping for ipsets/aliases

[pve-devel] [PATCH v3 manager 0/3]fix 2515 use size defaults
 2023-06-15  7:40 UTC  (2+ messages)

[pve-devel] [PATCH manager 1/2] api: ceph: remove deprecrated Pools path
 2023-06-15  7:39 UTC  (2+ messages)
` [pve-devel] [PATCH manager 2/2] api: ceph: remove deprecrated config and configdb endpoints

[pve-devel] [PATCH pve-network 0/2] fix zones status
 2023-06-14 19:41 UTC  (7+ messages)
` [pve-devel] [PATCH pve-network 1/2] zones: fix status
  ` [pve-devel] applied: "
` [pve-devel] [PATCH pve-network 2/2] zones: status: add a special message if vnet is not generated

[pve-devel] [PATCH common] syslog: interpret priority level 'warn' correctly
 2023-06-14 15:43 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH manager v2 0/4] improve ui for reaml sync jobs
 2023-06-14 15:42 UTC  (6+ messages)
` [pve-devel] [PATCH manager v2 1/4] ui: realm sync edit: improve ux when there is no ldap/ad realm
  ` [pve-devel] applied-series: "
` [pve-devel] [PATCH manager v2 2/4] ui: realm sync: change enabled column rendering
` [pve-devel] [PATCH manager v2 3/4] ui: realm: move sync job panel into realm panel
` [pve-devel] [PATCH manager v2 4/4] ui: realm sync: add 'run now' button

[pve-devel] [PATCH container v2 0/2] add test for LXC_NAME hosts entry and fix a minor glitch
 2023-06-14 14:25 UTC  (4+ messages)
` [pve-devel] [PATCH container v2 1/2] tests: fix small syntax glitch
` [pve-devel] [PATCH container v2 2/2] tests: add minimal test for LXC_NAME hosts entry
` [pve-devel] applied-series: [PATCH container v2 0/2] add test for LXC_NAME hosts entry and fix a minor glitch

[pve-devel] [PATCH manager] fix #4739: ui: add group column in user list
 2023-06-14 14:18 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH manager/container/guest-common 0/4] fix #3069: add pbs-entries-max to vzdump.conf
 2023-06-14 13:57 UTC  (10+ messages)
` [pve-devel] [PATCH manager 1/4] api: backup: refactor backup permission check
` [pve-devel] [PATCH manager 2/4] add 'pbs-entries-max' to permission check & config
` [pve-devel] [PATCH container 3/4] add 'pbs-entries-max' parameter
` [pve-devel] [PATCH guest-common 4/4] vzdump: schema: add 'pbs-entries-max' property

[pve-devel] [PATCH storage] Revert "workaround zfs create -V error for unaligned sizes"
 2023-06-14 12:26 UTC  (5+ messages)

[pve-devel] [PATCH docs] Update and extend permission documentation
 2023-06-14 11:43 UTC  (2+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH qemu-server] status: fix description of qmpstatus property
 2023-06-14 11:34 UTC  (3+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH container 0/2] add test for LXC_NAME hosts entry and fix a minor glitch
 2023-06-14 11:32 UTC  (4+ messages)
` [pve-devel] [PATCH container 1/2] tests: fix small syntax glitch
` [pve-devel] [PATCH container 2/2] tests: add minimal test for LXC_NAME hosts entry

[pve-devel] [PATCH v2 storage 1/2] rbd: improve handling of missing images
 2023-06-14 11:10 UTC  (2+ messages)
` [pve-devel] [PATCH v2 manager 2/2] ui: ContentView: don't show size if it is -1

[pve-devel] [PATCH manager 0/3] rework node console permission checks
 2023-06-14 10:42 UTC  (4+ messages)
` [pve-devel] [PATCH manager 1/3] node console: restrict all non-login commands to root@pam
` [pve-devel] [PATCH manager 2/3] node console: allow usage for non-pam realms
` [pve-devel] [RFC manager 3/3] node console: lift root@pam restriction for commands

[pve-devel] [PATCH manager 1/2] ui: config panel: only set onlineHelp if it exists
 2023-06-14  9:50 UTC  (2+ messages)
` [pve-devel] [PATCH manager 2/2] ui: group storages in folder view

[pve-devel] [PATCH v2 common 1/4] fix #3893: network: make bridge vids configurable
 2023-06-14  9:34 UTC  (5+ messages)
` [pve-devel] [PATCH widget-toolkit 2/4] fix #3892: Network: add bridge vids field for bridge_vids
` [pve-devel] [PATCH v2 manager 3/4] fix #3893: api: network: add bridge_vids parameter
` [pve-devel] [PATCH v2 manager 4/4] fix #3893: ui: network: enable bridge_vids field

[pve-devel] [PATCH container] setup: template_fixup: remove bogus LXC_NAME line from /etc/hosts
 2023-06-13 16:46 UTC  (4+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH zfsonlinux 0/2] update to 2.1.12
 2023-06-13 14:48 UTC  (4+ messages)
` [pve-devel] [PATCH zfsonlinux 1/2] update zfs submodule "
` [pve-devel] [PATCH zfsonlinux 2/2] /lib/zfs-linux/trim: don't exit 1 if last pool isn't nvme-only (Closes: #1030316)
` [pve-devel] applied-series: [PATCH zfsonlinux 0/2] update to 2.1.12

[pve-devel] [PATCH widget-toolkit] window: addtotp: Increase the size of the quiet zone
 2023-06-13 13:32 UTC 

[pve-devel] [PATCH access-control/guest-common/qemu-server/manager v5] cluster mapping
 2023-06-13 12:46 UTC  (9+ messages)
` [pve-devel] [PATCH qemu-server v5 1/6] enable cluster mapped USB devices for guests
` [pve-devel] [PATCH qemu-server v5 3/6] check_local_resources: extend for mapped resources
` [pve-devel] [PATCH qemu-server v5 4/6] api: migrate preconditions: use new check_local_resources info
` [pve-devel] [PATCH v5 02/15] api: add resource map api endpoints for PCI and USB

[pve-devel] [PATCH manager 1/2] pve7to8: refactor user.cfg loop
 2023-06-13 11:50 UTC  (2+ messages)
` [pve-devel] [PATCH manager 2/2] pve7to8: add check for dropped Permissions.Modify

[pve-devel] [PATCH pve-network] fix permissions && use new /sdn/zones/<zone>/<vnet> path
 2023-06-13  7:35 UTC  (4+ messages)
` [pve-devel] applied: "

[pve-devel] [PATCH qemu-server] fix #4549: capture and bubble up qemu errors correctly
 2023-06-13  7:05 UTC  (4+ messages)

[pve-devel] [PATCH v2 ha-manager 1/2] tests: simulate stale maintainance node caused by simultaneous cluster shutdown
 2023-06-13  7:00 UTC  (4+ messages)
` [pve-devel] [PATCH v2 ha-manager 2/2] manager: clear stale maintenance "
  ` [pve-devel] applied: "
` [pve-devel] applied: [PATCH v2 ha-manager 1/2] tests: simulate stale maintainance "

[pve-devel] appllied: [PATCH] read firstline: only map ENOENT to undef, raise error otherwise
 2023-06-13  5:32 UTC  (3+ messages)

[pve-devel] [PATCH-SERIES v6 qemu-server/manager] add and set x86-64-v2-AES as default model for new vms
 2023-06-12 16:23 UTC  (2+ messages)
` [pve-devel] applied-series: "

[pve-devel] [PATCH manager stable-7] pve7to8: add check for nvidia-vgpu-mgr
 2023-06-12 15:15 UTC  (2+ messages)
` [pve-devel] applied: "

page:  |  | latest

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal