public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
From: Dominik Csapak <d.csapak@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [pve-devel] [PATCH docs v2 1/2] qm: resource mapping: add description for `mdev` option
Date: Wed, 10 Apr 2024 13:04:00 +0200	[thread overview]
Message-ID: <20240410110401.2226201-22-d.csapak@proxmox.com> (raw)
In-Reply-To: <20240410110401.2226201-1-d.csapak@proxmox.com>

in a new section about additional options

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
---
 qm.adoc | 13 +++++++++++++
 1 file changed, 13 insertions(+)

diff --git a/qm.adoc b/qm.adoc
index 1170dd1..c146ce9 100644
--- a/qm.adoc
+++ b/qm.adoc
@@ -1734,6 +1734,19 @@ To create mappings `Mapping.Modify` on `/mapping/<type>/<name>` is necessary
 To use these mappings, `Mapping.Use` on `/mapping/<type>/<name>` is necessary
 (in addition to the normal guest privileges to edit the configuration).
 
+Additional Options
+^^^^^^^^^^^^^^^^^^
+
+There are additional options when defining a cluster wide resource mapping.
+Currently there are the following options:
+
+* `mdev` (PCI): This marks the PCI device as being capable of providing
+  `mediated devices`. When this is enabled, you can select a type when
+  configuring it on the guest. If multiple PCI devices are selected for
+  the mapping, the mediated device will be create on the first one where
+  there are any available instances of the selected type.
+
+
 Managing Virtual Machines with `qm`
 ------------------------------------
 
-- 
2.39.2





  parent reply	other threads:[~2024-04-10 11:13 UTC|newest]

Thread overview: 25+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2024-04-10 11:03 [pve-devel] [PATCH guest-common/qemu-server/manager/docs v2] implement experimental vgpu live migration Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH guest-common v2 1/5] mapping: pci: fix missing description/default for mdev Dominik Csapak
2024-04-11 16:27   ` [pve-devel] applied: " Thomas Lamprecht
2024-04-10 11:03 ` [pve-devel] [PATCH guest-common v2 2/5] mapping: pci: rework properties check Dominik Csapak
2024-04-11 16:49   ` Thomas Lamprecht
2024-04-10 11:03 ` [pve-devel] [PATCH guest-common v2 3/5] mapping: pci: check the mdev configuration on the device too Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH guest-common v2 4/5] mapping: pci: add 'live-migration-capable' flag to mappings Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH guest-common v2 5/5] mapping: remove find_on_current_node Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 01/10] usb: mapping: move implementation of find_on_current_node here Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 02/10] pci: " Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 03/10] pci: mapping: check mdev config against hardware Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 04/10] stop cleanup: remove unnecessary tpmstate cleanup Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 05/10] vm_stop_cleanup: add noerr parameter Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 06/10] migrate: call vm_stop_cleanup after stopping in phase3_cleanup Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 07/10] pci: set 'enable-migration' to on for live-migration marked mapped devices Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 08/10] check_local_resources: add more info per mapped device and return as hash Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 09/10] api: enable live migration for marked mapped pci devices Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH qemu-server v2 10/10] api: include not mapped resources for running vms in migrate preconditions Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH manager v2 1/5] mapping: pci: include mdev in config checks Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH manager v2 2/5] bulk migrate: improve precondition checks Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH manager v2 3/5] bulk migrate: include checks for live-migratable local resources Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH manager v2 4/5] ui: adapt migration window to precondition api change Dominik Csapak
2024-04-10 11:03 ` [pve-devel] [PATCH manager v2 5/5] fix #5175: ui: allow configuring and live migration of mapped pci resources Dominik Csapak
2024-04-10 11:04 ` Dominik Csapak [this message]
2024-04-10 11:04 ` [pve-devel] [PATCH docs v2 2/2] qm: resource mapping: document `live-migration-capable` setting Dominik Csapak

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20240410110401.2226201-22-d.csapak@proxmox.com \
    --to=d.csapak@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal