Raise the minimum ram required for a PVE instance.
Also specify the minimum and recommended disk space for a PVE instance in GiB.

Signed-off-by: Noel Ullreich <n.ullreich@proxmox.com>
---
 pve-system-requirements.adoc | 12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)

diff --git a/pve-system-requirements.adoc b/pve-system-requirements.adoc
index bb474ac..4e789a4 100644
--- a/pve-system-requirements.adoc
+++ b/pve-system-requirements.adoc
@@ -22,9 +22,9 @@ used in production.
 
 * Intel VT/AMD-V capable CPU/Mainboard for KVM full virtualization support
 
-* RAM: 1 GB RAM, plus additional RAM needed for guests
+* RAM: 2 GiB RAM, plus additional RAM needed for guests
 
-* Hard drive
+* Disk Space: a hard drive with at least a 16 GiB capacity
 
 * One network card (NIC)
 
@@ -35,14 +35,14 @@ Recommended System Requirements
 
 * Intel EMT64 or AMD64 with Intel VT/AMD-V CPU flag.
 
-* Memory: Minimum 2 GB for the OS and {pve} services, plus designated memory for
-  guests. For Ceph and ZFS, additional memory is required; approximately 1GB of
-  memory for every TB of used storage.
+* Memory: Minimum 4 GiB for the OS and {pve} services, plus designated memory for
+  guests. For Ceph and ZFS, additional memory is required; approximately 1 GiB of
+  memory for every TiB of used storage.
 
 * Fast and redundant storage, best results are achieved with SSDs.
 
 * OS storage: Use a hardware RAID with battery protected write cache (``BBU'')
-  or non-RAID with ZFS (optional SSD for ZIL).
+  or non-RAID with ZFS (optional SSD for ZIL) with at least a 32 GiB capacity.
 
 * VM storage:
 ** For local storage, use either a hardware RAID with battery backed write cache
-- 
2.39.2





  parent reply	other threads:[~2023-07-10 13:50 UTC|newest]

Thread overview: 8+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2023-07-10 13:49 [pve-devel] [PATCH pve-installer; pve-docs; pmg-docs; proxmox-backup/docs 0/4] Update min RAM and min disk size for pve Noel Ullreich
2023-07-10 13:49 ` [pve-devel] [PATCH pve-installer 1/1] raise the minimum ram requirements to 2 GiB Noel Ullreich
2023-07-10 13:49 ` [pve-devel] [PATCH pmg_docs 1/1] Consistency of GB and GiB pmg Noel Ullreich
2024-01-22 17:58   ` [pve-devel] applied: " Stoiko Ivanov
2024-02-06 12:20     ` Thomas Lamprecht
2024-02-13 10:37       ` Stoiko Ivanov
2023-07-10 13:49 ` Noel Ullreich [this message]
2023-07-10 13:49 ` [pve-devel] [PATCH proxmox-backup/docs 1/1] Consistency of GB and GiB pbs Noel Ullreich

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20230710134951.79263-4-n.ullreich@proxmox.com \
    --to=n.ullreich@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal