From: Stefan Hrdlicka <s.hrdlicka@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [pve-devel] [PATCH V6 pve-manager 0/2] fix #2822: add iscsi, lvm, lvmthin & zfs
Date: Fri, 30 Sep 2022 14:38:00 +0200 [thread overview]
Message-ID: <20220930123802.772865-1-s.hrdlicka@proxmox.com> (raw)
V1 -> V2:
# pve-storage
* removed because patch is not needed
# pve-manager (1/3)
* remove storage controller from V1
* added custom ComboBox with API URL & setNodeName function
* added scan node selection for iSCSI
* scan node selection field no longer send to server
## (optional) pve-manager (2/3): cleanup related files
* var to let statement change
* some indentation
## ((very) optional) pve-manager (3/3): cleanup all var statements
* replaces all var with let statements
V2 -> V3:
# pve-manager (1/2)
* fix broken interface (broken in V2 )
* improve tooltip
* replace jNodeSelector function with class object
(PVE.panel.StorageBaseWithNodeSelector)
# other things:
* removed very optional cleanup
* nothing changed for "Base storage" selector. It is still possible to
select for example an iSCSI device only availabe on one node that
isn't availabe on the other ones. I wasn't sure if this should be
changed in this context as well.
V3 -> V4:
# pve-manager (1/2)
* "localhost" is set for "Scan Node"
* if another node is selcted and the "X" (clear) is used, localhost is
set as the value again
* use lookupReference
* moved used template literals for building path strings
V4 -> V5:
# pve-manager (1/2)
* s/lookupReference/lookup/
* move ComboBoxSetStoreNode & StrageScanNodeSelector
to www/manager6/form
* move array pushes to initialization of array
V5 -> V6:
# pve-manager (1/2)
* set default value of "Scan node" to Proxmox.NodeName
* don't allow empty "Scan node"
Stefan Hrdlicka (2):
fix #2822: add iscsi, lvm, lvmthin & zfs storage for all cluster nodes
cleanup: "var" to "let", fix some indentation in related files
www/manager6/Makefile | 2 +
www/manager6/form/ComboBoxSetStoreNode.js | 16 +++++
www/manager6/form/StorageScanNodeSelector.js | 31 +++++++++
www/manager6/storage/Base.js | 11 +--
www/manager6/storage/IScsiEdit.js | 35 +++++++---
www/manager6/storage/LVMEdit.js | 43 +++++++++---
www/manager6/storage/LvmThinEdit.js | 70 ++++++++++++++------
www/manager6/storage/ZFSPoolEdit.js | 51 +++++++++-----
8 files changed, 199 insertions(+), 60 deletions(-)
create mode 100644 www/manager6/form/ComboBoxSetStoreNode.js
create mode 100644 www/manager6/form/StorageScanNodeSelector.js
--
2.30.2
next reply other threads:[~2022-09-30 12:38 UTC|newest]
Thread overview: 5+ messages / expand[flat|nested] mbox.gz Atom feed top
2022-09-30 12:38 Stefan Hrdlicka [this message]
2022-09-30 12:38 ` [pve-devel] [PATCH V6 pve-manager 1/2] fix #2822: add iscsi, lvm, lvmthin & zfs storage for all cluster nodes Stefan Hrdlicka
2022-09-30 12:38 ` [pve-devel] [PATCH V6 pve-manager 2/2] cleanup: "var" to "let", fix some indentation in related files Stefan Hrdlicka
2022-10-21 9:24 ` [pve-devel] [PATCH V6 pve-manager 0/2] fix #2822: add iscsi, lvm, lvmthin & zfs Dominik Csapak
2022-12-13 12:12 ` Thomas Lamprecht
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20220930123802.772865-1-s.hrdlicka@proxmox.com \
--to=s.hrdlicka@proxmox.com \
--cc=pve-devel@lists.proxmox.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox