public inbox for pve-devel@lists.proxmox.com
 help / color / mirror / Atom feed
From: Aaron Lauterer <a.lauterer@proxmox.com>
To: pve-devel@lists.proxmox.com
Subject: [pve-devel] [PATCH v5 qemu-server 2/5] disk reassign: add API endpoint
Date: Tue, 15 Dec 2020 13:48:37 +0100	[thread overview]
Message-ID: <20201215124840.29914-3-a.lauterer@proxmox.com> (raw)
In-Reply-To: <20201215124840.29914-1-a.lauterer@proxmox.com>

The goal of this new API endpoint is to provide an easy way to move a
disk between VMs as this was only possible with manual intervention
until now. Either by renaming the VM disk or by manually adding the
disks volid to the config of the other VM.

The latter can easily cause unexpected behavior such as disks attached
to VM B would be deleted if it used to be a disk of VM A. This happens
because PVE assumes that the VMID in the volname always matches the VM
the disk is attached to and thus, would remove any disk with VMID A
when VM A was deleted.

The term `reassign` was chosen as it is not yet used
for VM disks.

Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
---
v4 -> v5:
* implemented suggestions from Fabian [1]
    * logging before action
    * improving description
    * improving error messages
    * using Replication::prepare to remove replication snapshots
    * check if disk is physical disk using /dev/...

v3 -> v4: nothing

v2 -> v3:
* reordered the locking as discussed with fabian [0] to
run checks
    fork worker
	lock source config
	    lock target config
		run checks
		...

* added more checks
    * will not reassign to or from templates
    * will not reassign if VM has snapshots present
* cleanup if disk used to be replicated
* made task log slightly more verbose
* integrated general recommendations regarding code
* renamed `disk` to `drive_key`
* prepended some vars with `source_` for easier distinction

v1 -> v2: print config key and volid info at the end of the job so it
shows up on the CLI and task log

rfc -> v1:
* add support to reassign unused disks
* add support to provide a config digest for the target vm
* add additional check if disk key is present in config
* reorder checks a bit

In order to support unused disk I had to extend
PVE::QemuServer::Drive::valid_drive_names for the API parameter
validation.

Checks are ordered so that cheap tests are run at the first chance to
fail early.

The check if both VMs are present on the node is a bit redundant because
locking the config files will fail if the VM is not present. But with
the additional check we can provide a useful error message to the user
instead of a "Configuration file xyz does not exist" error.

[0] https://lists.proxmox.com/pipermail/pve-devel/2020-September/044930.html
[1] https://lists.proxmox.com/pipermail/pve-devel/2020-November/046030.html

 PVE/API2/Qemu.pm        | 151 ++++++++++++++++++++++++++++++++++++++++
 PVE/QemuServer/Drive.pm |   4 ++
 2 files changed, 155 insertions(+)

diff --git a/PVE/API2/Qemu.pm b/PVE/API2/Qemu.pm
index 00d98ab..614f068 100644
--- a/PVE/API2/Qemu.pm
+++ b/PVE/API2/Qemu.pm
@@ -35,6 +35,7 @@ use PVE::API2::Qemu::Agent;
 use PVE::VZDump::Plugin;
 use PVE::DataCenterConfig;
 use PVE::SSHInfo;
+use PVE::Replication;
 
 BEGIN {
     if (!$ENV{PVE_GENERATING_DOCS}) {
@@ -4319,4 +4320,154 @@ __PACKAGE__->register_method({
 	return PVE::QemuServer::Cloudinit::dump_cloudinit_config($conf, $param->{vmid}, $param->{type});
     }});
 
+__PACKAGE__->register_method({
+    name => 'reassign_vm_disk',
+    path => '{vmid}/reassign_disk',
+    method => 'POST',
+    protected => 1,
+    proxyto => 'node',
+    description => "Reassign a disk to another VM",
+    permissions => {
+	description => "You need 'VM.Config.Disk' permissions on /vms/{vmid} and /vms/{target vmid}, and 'Datastore.Allocate' permissions on the storage.",
+	check => [ 'and',
+		   ['perm', '/vms/{vmid}', [ 'VM.Config.Disk' ]],
+		   ['perm', '/storage/{storage}', [ 'Datastore.Allocate' ]],
+	    ],
+    },
+    parameters => {
+        additionalProperties => 0,
+	properties => {
+	    node => get_standard_option('pve-node'),
+	    vmid => get_standard_option('pve-vmid', { completion => \&PVE::QemuServer::complete_vmid }),
+	    target_vmid => get_standard_option('pve-vmid', { completion => \&PVE::QemuServer::complete_vmid }),
+	    drive_name => {
+	        type => 'string',
+		description => "The config key of the disk to reassign (for example, ide0 or scsi1).",
+		enum => [PVE::QemuServer::Drive::valid_drive_names_with_unused()],
+	    },
+	    digest => {
+		type => 'string',
+		description => 'Prevent changes if current the configuration file of the source VM has a different SHA1 digest. This can be used to prevent concurrent modifications.',
+		maxLength => 40,
+		optional => 1,
+	    },
+	    target_digest => {
+		type => 'string',
+		description => 'Prevent changes if current the configuration file of the target VM has a different SHA1 digest. This can be used to prevent concurrent modifications.',
+		maxLength => 40,
+		optional => 1,
+	    },
+	},
+    },
+    returns => {
+	type => 'string',
+	description => "the task ID.",
+    },
+    code => sub {
+	my ($param) = @_;
+
+	my $rpcenv = PVE::RPCEnvironment::get();
+	my $authuser = $rpcenv->get_user();
+
+	my $node = extract_param($param, 'node');
+	my $source_vmid = extract_param($param, 'vmid');
+	my $target_vmid = extract_param($param, 'target_vmid');
+	my $source_digest = extract_param($param, 'digest');
+	my $target_digest = extract_param($param, 'target_digest');
+	my $drive_name = extract_param($param, 'drive_name');
+
+	my $storecfg = PVE::Storage::config();
+	my $vmlist;
+	my $drive;
+	my $source_volid;
+
+	die "Reassigning a disk to the same VM is not possible. Did you mean to move the disk?\n"
+	    if $source_vmid eq $target_vmid;
+
+	my $load_and_check_configs = sub {
+	    $vmlist = PVE::Cluster::get_vmlist()->{ids};
+	    die "Both VMs need to be on the same node ($vmlist->{$source_vmid}->{node}) but target VM is on $vmlist->{$target_vmid}->{node}.\n"
+		if $vmlist->{$source_vmid}->{node} ne $vmlist->{$target_vmid}->{node};
+
+	    my $source_conf = PVE::QemuConfig->load_config($source_vmid);
+	    PVE::QemuConfig->check_lock($source_conf);
+	    my $target_conf = PVE::QemuConfig->load_config($target_vmid);
+	    PVE::QemuConfig->check_lock($target_conf);
+
+	    die "Can't reassign disks from or to templates\n"
+		if ($source_conf->{template} || $target_conf->{template});
+
+	    if ($source_digest) {
+		eval { PVE::Tools::assert_if_modified($source_digest, $source_conf->{digest}) };
+		if (my $err = $@) {
+		    die "VM ${source_vmid}: ${err}";
+		}
+	    }
+
+	    if ($target_digest) {
+		eval { PVE::Tools::assert_if_modified($target_digest, $target_conf->{digest}) };
+		if (my $err = $@) {
+		    die "VM ${target_vmid}: ${err}";
+		}
+	    }
+
+	    die "Disk '${drive_name}' does not exist\n"
+		if !defined($source_conf->{$drive_name});
+
+	    $drive = PVE::QemuServer::parse_drive($drive_name, $source_conf->{$drive_name});
+	    $source_volid = $drive->{file};
+	    die "disk '${drive_name}' has no associated volume\n" if !$source_volid;
+	    die "CD drive contents can't be reassigned\n" if PVE::QemuServer::drive_is_cdrom($drive, 1);
+	    die "Can't reassign physical disk\n" if $drive->{file} =~ m|^/dev/|;
+	    die "Can't reassign disk used by a snapshot\n"
+		if PVE::QemuServer::Drive::is_volume_in_use($storecfg, $source_conf, $drive_name, $source_volid);
+
+	    die "Storage does not support the reassignment of this disk\n"
+		if !PVE::Storage::volume_has_feature($storecfg, 'reassign', $source_volid);
+
+	    die "Cannot reassign disk while the source VM is running\n"
+		if PVE::QemuServer::check_running($source_vmid) && $drive_name !~ m/unused[0-9]/;
+
+	    return ($source_conf, $target_conf);
+	};
+
+	my $logfunc = sub {
+	    my ($msg) = @_;
+	    print STDERR "$msg\n";
+	};
+
+	my $reassign_func = sub {
+	    return PVE::QemuConfig->lock_config($source_vmid, sub {
+		return PVE::QemuConfig->lock_config($target_vmid, sub {
+		    my ($source_conf, $target_conf) = &$load_and_check_configs();
+
+		    PVE::Cluster::log_msg('info', $authuser, "reassign disk VM $source_vmid: reassign --disk ${drive_name} --target_vmid $target_vmid");
+
+		    my $new_volid = PVE::Storage::reassign_volume($storecfg, $source_volid, $target_vmid);
+
+		    delete $source_conf->{$drive_name};
+		    print "removing disk '${drive_name}' from VM '${source_vmid}'\n";
+		    PVE::QemuConfig->write_config($source_vmid, $source_conf);
+
+		    # remove possible replication snapshots
+		    PVE::Replication::prepare($storecfg, [$new_volid], undef, undef, undef, $logfunc);
+
+		    my $key;
+		    eval { $key = PVE::QemuConfig->add_unused_volume($target_conf, $new_volid) };
+		    if (my $err = $@) {
+			print "failed to add reassigned disk '${new_volid}' to VM '${target_vmid}'. Try to free an 'unused' disk slot and run 'qm rescan ${target_vmid}'.\n";
+			return 0;
+		    }
+
+		    print "adding disk to VM '${target_vmid}' as '${key}: ${new_volid}'\n";
+		    PVE::QemuConfig->write_config($target_vmid, $target_conf);
+		});
+	    });
+	};
+
+	&$load_and_check_configs();
+
+	return $rpcenv->fork_worker('qmreassign', $source_vmid, $authuser, $reassign_func);
+    }});
+
 1;
diff --git a/PVE/QemuServer/Drive.pm b/PVE/QemuServer/Drive.pm
index d560937..95c0538 100644
--- a/PVE/QemuServer/Drive.pm
+++ b/PVE/QemuServer/Drive.pm
@@ -383,6 +383,10 @@ sub valid_drive_names {
             'efidisk0');
 }
 
+sub valid_drive_names_with_unused {
+    return (valid_drive_names(), map {"unused$_"} (0 .. ($MAX_UNUSED_DISKS -1)));
+}
+
 sub is_valid_drivename {
     my $dev = shift;
 
-- 
2.20.1





  parent reply	other threads:[~2020-12-15 12:49 UTC|newest]

Thread overview: 10+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2020-12-15 12:48 [pve-devel] [PATCH v5 series 0/5] disk reassign: add new feature Aaron Lauterer
2020-12-15 12:48 ` [pve-devel] [PATCH v5 storage 1/5] add disk reassign feature Aaron Lauterer
2021-03-31  9:34   ` Fabian Grünbichler
2020-12-15 12:48 ` Aaron Lauterer [this message]
2021-03-31  9:23   ` [pve-devel] [PATCH v5 qemu-server 2/5] disk reassign: add API endpoint Fabian Grünbichler
2021-04-01 14:24     ` Aaron Lauterer
2020-12-15 12:48 ` [pve-devel] [PATCH v5 qemu-server 3/5] cli: disk reassign: add reassign_disk to qm command Aaron Lauterer
2020-12-15 12:48 ` [pve-devel] [PATCH v5 guest-common 4/5] Replication: mention disk reassign in comment of possible reasons Aaron Lauterer
2020-12-15 12:48 ` [pve-devel] [PATCH v5 manager 5/5] ui: tasks: add qmreassign task description Aaron Lauterer
2021-02-15 14:59 ` [pve-devel] [PATCH v5 series 0/5] disk reassign: add new feature Aaron Lauterer

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20201215124840.29914-3-a.lauterer@proxmox.com \
    --to=a.lauterer@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal