all lists on lists.proxmox.com
 help / color / mirror / Atom feed
From: Fabian Ebner <f.ebner@proxmox.com>
To: pve-devel@lists.proxmox.com, a.lauterer@proxmox.com
Subject: Re: [pve-devel] [PATCH v6 qemu-server 2/5] disk reassign: add API endpoint
Date: Thu, 15 Apr 2021 13:52:33 +0200	[thread overview]
Message-ID: <cf8cf8fb-89a2-4b29-6e86-b601526bc956@proxmox.com> (raw)
In-Reply-To: <20210402101923.13050-3-a.lauterer@proxmox.com>

One nit and one comment inline.

Am 02.04.21 um 12:19 schrieb Aaron Lauterer:
> The goal of this new API endpoint is to provide an easy way to move a
> disk between VMs as this was only possible with manual intervention
> until now. Either by renaming the VM disk or by manually adding the
> disks volid to the config of the other VM.
> 
> The latter can easily cause unexpected behavior such as disks attached
> to VM B would be deleted if it used to be a disk of VM A. This happens
> because PVE assumes that the VMID in the volname always matches the VM
> the disk is attached to and thus, would remove any disk with VMID A
> when VM A was deleted.
> 
> The term `reassign` was chosen as it is not yet used
> for VM disks.
> 
> Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
> ---
> v5 -> v6:
> * guard Replication snapshot cleanup
>      additionally to the eval, that code is now only run if the volume is
>      on a storage with the 'replicate' feature
> * add permission check for target vmid
> * changed regex to match unused keys better
> 
> thx @Fabian for these suggestions/catching problems
> 
> v4 -> v5:
> * implemented suggestions from Fabian [1]
>      * logging before action
>      * improving description
>      * improving error messages
>      * using Replication::prepare to remove replication snapshots
>      * check if disk is physical disk using /dev/...
> 
> v3 -> v4: nothing
> 
> v2 -> v3:
> * reordered the locking as discussed with fabian [0] to
> run checks
>      fork worker
> 	lock source config
> 	    lock target config
> 		run checks
> 		...
> 
> * added more checks
>      * will not reassign to or from templates
>      * will not reassign if VM has snapshots present
> * cleanup if disk used to be replicated
> * made task log slightly more verbose
> * integrated general recommendations regarding code
> * renamed `disk` to `drive_key`
> * prepended some vars with `source_` for easier distinction
> 
> v1 -> v2: print config key and volid info at the end of the job so it
> shows up on the CLI and task log
> 
> rfc -> v1:
> * add support to reassign unused disks
> * add support to provide a config digest for the target vm
> * add additional check if disk key is present in config
> * reorder checks a bit
> 
> In order to support unused disk I had to extend
> PVE::QemuServer::Drive::valid_drive_names for the API parameter
> validation.
> 
> Checks are ordered so that cheap tests are run at the first chance to
> fail early.
> 
> The check if both VMs are present on the node is a bit redundant because
> locking the config files will fail if the VM is not present. But with
> the additional check we can provide a useful error message to the user
> instead of a "Configuration file xyz does not exist" error.
> 
> [0] https://lists.proxmox.com/pipermail/pve-devel/2020-September/044930.html
> [1] https://lists.proxmox.com/pipermail/pve-devel/2020-November/046030.html
> 
>   PVE/API2/Qemu.pm        | 172 ++++++++++++++++++++++++++++++++++++++++
>   PVE/QemuServer/Drive.pm |   4 +
>   2 files changed, 176 insertions(+)
> 
> diff --git a/PVE/API2/Qemu.pm b/PVE/API2/Qemu.pm
> index e95ab13..9642b9b 100644
> --- a/PVE/API2/Qemu.pm
> +++ b/PVE/API2/Qemu.pm
> @@ -35,6 +35,7 @@ use PVE::API2::Qemu::Agent;
>   use PVE::VZDump::Plugin;
>   use PVE::DataCenterConfig;
>   use PVE::SSHInfo;
> +use PVE::Replication;
>   
>   BEGIN {
>       if (!$ENV{PVE_GENERATING_DOCS}) {
> @@ -4377,4 +4378,175 @@ __PACKAGE__->register_method({
>   	return PVE::QemuServer::Cloudinit::dump_cloudinit_config($conf, $param->{vmid}, $param->{type});
>       }});
>   
> +__PACKAGE__->register_method({
> +    name => 'reassign_vm_disk',
> +    path => '{vmid}/reassign_disk',
> +    method => 'POST',
> +    protected => 1,
> +    proxyto => 'node',
> +    description => "Reassign a disk to another VM",
> +    permissions => {
> +	description => "You need 'VM.Config.Disk' permissions on /vms/{vmid} and /vms/{target vmid}, and 'Datastore.Allocate' permissions on the storage.",
> +	check => [ 'and',
> +		   ['perm', '/vms/{vmid}', [ 'VM.Config.Disk' ]],
> +		   ['perm', '/storage/{storage}', [ 'Datastore.Allocate' ]],
> +	    ],
> +    },
> +    parameters => {
> +        additionalProperties => 0,
> +	properties => {
> +	    node => get_standard_option('pve-node'),
> +	    vmid => get_standard_option('pve-vmid', { completion => \&PVE::QemuServer::complete_vmid }),
> +	    target_vmid => get_standard_option('pve-vmid', { completion => \&PVE::QemuServer::complete_vmid }),
> +	    drive_name => {
> +	        type => 'string',
> +		description => "The config key of the disk to reassign (for example, ide0 or scsi1).",
> +		enum => [PVE::QemuServer::Drive::valid_drive_names_with_unused()],
> +	    },
> +	    digest => {
> +		type => 'string',
> +		description => 'Prevent changes if current the configuration file of the source VM has a different SHA1 digest. This can be used to prevent concurrent modifications.',
> +		maxLength => 40,
> +		optional => 1,
> +	    },
> +	    target_digest => {
> +		type => 'string',
> +		description => 'Prevent changes if current the configuration file of the target VM has a different SHA1 digest. This can be used to prevent concurrent modifications.',
> +		maxLength => 40,
> +		optional => 1,
> +	    },
> +	},
> +    },
> +    returns => {
> +	type => 'string',
> +	description => "the task ID.",
> +    },
> +    code => sub {
> +	my ($param) = @_;
> +
> +	my $rpcenv = PVE::RPCEnvironment::get();
> +	my $authuser = $rpcenv->get_user();
> +
> +	my $node = extract_param($param, 'node');
> +	my $source_vmid = extract_param($param, 'vmid');
> +	my $target_vmid = extract_param($param, 'target_vmid');
> +	my $source_digest = extract_param($param, 'digest');
> +	my $target_digest = extract_param($param, 'target_digest');
> +	my $drive_name = extract_param($param, 'drive_name');
> +
> +	my $storecfg = PVE::Storage::config();
> +	my $vmlist; > +	my $drive;
> +	my $source_volid;
Nit: $vmlist and $drive are only ever used within the 
load_and_check_configs closure, so they can be declared there

> +
> +	$rpcenv->check_vm_perm($authuser, $target_vmid, undef, ['VM.Config.Disk'])
> +	    if $authuser ne 'root@pam';
> +
> +	die "Reassigning a disk to the same VM is not possible. Did you mean to move the disk?\n"
> +	    if $source_vmid eq $target_vmid;
> +
> +	my $load_and_check_configs = sub {
> +	    $vmlist = PVE::Cluster::get_vmlist()->{ids};
> +	    die "Both VMs need to be on the same node ($vmlist->{$source_vmid}->{node}) but target VM is on $vmlist->{$target_vmid}->{node}.\n"
> +		if $vmlist->{$source_vmid}->{node} ne $vmlist->{$target_vmid}->{node};
> +
> +	    my $source_conf = PVE::QemuConfig->load_config($source_vmid);
> +	    PVE::QemuConfig->check_lock($source_conf);
> +	    my $target_conf = PVE::QemuConfig->load_config($target_vmid);
> +	    PVE::QemuConfig->check_lock($target_conf);
> +
> +	    die "Can't reassign disks from or to templates\n"
> +		if ($source_conf->{template} || $target_conf->{template});
> +
> +	    if ($source_digest) {
> +		eval { PVE::Tools::assert_if_modified($source_digest, $source_conf->{digest}) };
> +		if (my $err = $@) {
> +		    die "VM ${source_vmid}: ${err}";
> +		}
> +	    }
> +
> +	    if ($target_digest) {
> +		eval { PVE::Tools::assert_if_modified($target_digest, $target_conf->{digest}) };
> +		if (my $err = $@) {
> +		    die "VM ${target_vmid}: ${err}";
> +		}
> +	    }
> +
> +	    die "Disk '${drive_name}' does not exist\n"
> +		if !defined($source_conf->{$drive_name});
> +
> +	    $drive = PVE::QemuServer::parse_drive($drive_name, $source_conf->{$drive_name});
> +	    $source_volid = $drive->{file};
> +	    die "disk '${drive_name}' has no associated volume\n" if !$source_volid;
> +	    die "CD drive contents can't be reassigned\n" if PVE::QemuServer::drive_is_cdrom($drive, 1);
> +	    die "Can't reassign physical disk\n" if $drive->{file} =~ m|^/dev/|;
> +	    die "Can't reassign disk used by a snapshot\n"
> +		if PVE::QemuServer::Drive::is_volume_in_use($storecfg, $source_conf, $drive_name, $source_volid);
> +
> +	    die "Storage does not support the reassignment of this disk\n"
> +		if !PVE::Storage::volume_has_feature($storecfg, 'reassign', $source_volid);
> +
> +	    die "Cannot reassign disk while the source VM is running\n"
> +		if PVE::QemuServer::check_running($source_vmid) && $drive_name !~ m/^unused\d+$/;
> +
> +	    return ($source_conf, $target_conf);
> +	};
> +
> +	my $logfunc = sub {
> +	    my ($msg) = @_;
> +	    print STDERR "$msg\n";
> +	};
> +
> +	my $reassign_func = sub {
> +	    return PVE::QemuConfig->lock_config($source_vmid, sub {
> +		return PVE::QemuConfig->lock_config($target_vmid, sub {
> +		    my ($source_conf, $target_conf) = &$load_and_check_configs();
> +
> +		    PVE::Cluster::log_msg('info', $authuser, "reassign disk VM $source_vmid: reassign --disk ${drive_name} --target_vmid $target_vmid");
> +
> +		    my $new_volid = PVE::Storage::reassign_volume(
> +			$storecfg,
> +			$source_volid,
> +			$target_vmid,
> +		    );
> +
> +		    delete $source_conf->{$drive_name};
> +		    print "removing disk '${drive_name}' from VM '${source_vmid}'\n";
> +		    PVE::QemuConfig->write_config($source_vmid, $source_conf);
> +
> +		    # remove possible replication snapshots
> +		    if (PVE::Storage::volume_has_feature($storecfg, 'replicate', $source_volid)) {
> +			eval {
> +			    PVE::Replication::prepare(
> +				$storecfg,
> +				[$new_volid],
> +				undef,
> +				undef,

To actually remove the replication snapshots, you need to use 1 for 
last_sync. undef defaults to 0 and does not remove the replication 
snapshots. 0 happens when a VM was stolen, but replication snapshots for 
stolen VMs are still valid!

The good news is that patch 4 isn't needed ;)

> +				undef,
> +				$logfunc,
> +			    )
> +			};
> +			if (my $err = $@) {
> +			    print "Failed to remove replication snapshots on reassigned disk. Manual cleanup could be necessary.\n";
> +			}
> +		    }
> +
> +		    my $key;
> +		    eval { $key = PVE::QemuConfig->add_unused_volume($target_conf, $new_volid) };
> +		    if (my $err = $@) {
> +			print "failed to add reassigned disk '${new_volid}' to VM '${target_vmid}'. Try to free an 'unused' disk slot and run 'qm rescan ${target_vmid}'.\n";
> +			return 0;
> +		    }
> +
> +		    print "adding disk to VM '${target_vmid}' as '${key}: ${new_volid}'\n";
> +		    PVE::QemuConfig->write_config($target_vmid, $target_conf);
> +		});
> +	    });
> +	};
> +
> +	&$load_and_check_configs();
> +
> +	return $rpcenv->fork_worker('qmreassign', $source_vmid, $authuser, $reassign_func);
> +    }});
> +
>   1;
> diff --git a/PVE/QemuServer/Drive.pm b/PVE/QemuServer/Drive.pm
> index 01ea8d7..e938b9b 100644
> --- a/PVE/QemuServer/Drive.pm
> +++ b/PVE/QemuServer/Drive.pm
> @@ -392,6 +392,10 @@ sub valid_drive_names {
>               'efidisk0');
>   }
>   
> +sub valid_drive_names_with_unused {
> +    return (valid_drive_names(), map {"unused$_"} (0 .. ($MAX_UNUSED_DISKS -1)));
> +}
> +
>   sub is_valid_drivename {
>       my $dev = shift;
>   
> 




  reply	other threads:[~2021-04-15 11:53 UTC|newest]

Thread overview: 18+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-04-02 10:19 [pve-devel] [PATCH v6 series 0/5] disk reassign: add new feature Aaron Lauterer
2021-04-02 10:19 ` [pve-devel] [PATCH v6 storage 1/1] add disk reassign feature Aaron Lauterer
2021-04-13  7:53   ` Dominic Jäger
2021-04-15 11:07   ` Fabian Ebner
2021-04-15 11:31     ` Fabian Ebner
2021-04-15 11:53       ` Aaron Lauterer
2021-04-15 12:09         ` Fabian Ebner
2021-04-15 12:21           ` Thomas Lamprecht
2021-04-15 12:20         ` Thomas Lamprecht
2021-04-02 10:19 ` [pve-devel] [PATCH v6 qemu-server 2/5] disk reassign: add API endpoint Aaron Lauterer
2021-04-15 11:52   ` Fabian Ebner [this message]
2021-04-19  9:26     ` Aaron Lauterer
2021-04-18 15:24   ` Thomas Lamprecht
2021-04-19  9:25     ` Aaron Lauterer
2021-04-02 10:19 ` [pve-devel] [PATCH v6 qemu-server 3/5] cli: disk reassign: add reassign_disk to qm command Aaron Lauterer
2021-04-18 14:50   ` Thomas Lamprecht
2021-04-02 10:19 ` [pve-devel] [PATCH v6 guest-common 4/5] Replication: mention disk reassign in comment of possible reasons Aaron Lauterer
2021-04-02 10:19 ` [pve-devel] [PATCH v6 manager 5/5] ui: tasks: add qmreassign task description Aaron Lauterer

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=cf8cf8fb-89a2-4b29-6e86-b601526bc956@proxmox.com \
    --to=f.ebner@proxmox.com \
    --cc=a.lauterer@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal