all lists on lists.proxmox.com
 help / color / mirror / Atom feed
* qemu-server: Severe I/O stalls moving VM disks from NFS to LVM-thin, resolved with -t none
@ 2026-10-28  7:41 RAFAEL SILVA
  0 siblings, 0 replies; only message in thread
From: RAFAEL SILVA @ 2026-10-28  7:41 UTC (permalink / raw)
  To: pve-devel

Hello Proxmox VE developers,

I would like to report an issue with VM disk moves from NFS storage to
LVM-thin using the Proxmox VE web interface.

I investigated the issue, identified a difference in the target cache mode
used by qemu-img, and successfully tested a local workaround.

*Environment*

   -

   Proxmox VE: 9.2.0
   -

   pve-manager: 9.2.21
   -

   qemu-server: 9.2.10
   -

   pve-qemu-kvm: 11.0.3-4
   -

   Kernel: 7.0.14-22-pve
   -

   libpve-storage-perl: 9.1.12
   -

   Source: TrueNAS NFS storage containing RAW VM images
   -

   Destination: local LVM-thin storage (local-lvm)
   -

   Hardware: Dell PowerEdge R710, PERC 6/i, four HDDs in RAID 5
   -

   RAID cache policy: WriteThrough (degraded BBU)

*Observed behavior*

Moving a powered-off VM disk from NFS to LVM-thin through the web interface
caused severe I/O congestion and host responsiveness issues.

During the operation, I observed approximately:

   -

   Write latency (w_await): 1,699 ms
   -

   Average queue size (aqu-sz): 104
   -

   Disk utilization: 94.5%
   -

   Write throughput: 10 MB/s

The problem persisted even with a 5 MiB/s conversion bandwidth limit.

It was reproducible with NFS datasets using both 64K and 128K ZFS record
sizes.

Disk moves in the opposite direction (LVM-thin to NFS) worked normally.

VMware ESXi imports into the same LVM-thin storage also worked normally.

*Command generated by Proxmox*

/usr/bin/qemu-img convert -p -n -r 5120K \
  -f raw -O raw -- \
  /mnt/pve/nas-nfs-vms/images/113/vm-113-disk-0.raw \
  zeroinit:/dev/pve/vm-113-disk-0

*Successful manual conversion*

qemu-img convert -p -n -f raw -O raw -t none -- \
  /mnt/pve/nas-nfs-vms/images/113/vm-113-disk-0.raw \
  zeroinit:/dev/pve/vm-113-disk-0

This completed successfully without the previously observed severe I/O
stalls.

I also verified that an ESXi import using -t none opened its destination
block device with O_DIRECT.

*Relevant implementation*

In PVE/QemuServer/QemuImage.pm, the convert() function contains:

push @$cmd, '-t', 'none' if $dst_scfg->{type} eq 'zfspool';

Therefore, the target cache mode is explicitly set to none for ZFS pool
destinations, but not for LVM-thin.

*Locally tested workaround*

I changed the condition to:

push @$cmd, '-t', 'none'
    if $dst_scfg->{type} eq 'zfspool'
    || ($dst_storeid eq 'local-lvm' && $dst_scfg->{type} eq 'lvmthin');

After applying this modification, VM disk moves from NFS to local-lvm
through the Proxmox web interface completed successfully without the
previous severe I/O stalls.

This workaround is intentionally limited to my local storage ID. I am not
proposing the storage-name-specific condition as an upstream solution.

*Additional testing observations*

The original disk move experienced severe I/O stalls even when the
conversion bandwidth was limited to 5 MiB/s.

Both the successful manual conversion and the subsequent successful
web-interface disk move were performed without a bandwidth limit, using -t
none.

Despite the absence of rate limiting, neither operation reproduced the
previously observed I/O congestion.

This suggests that the target cache mode may be a more significant factor
than the transfer rate itself.

However, since the bandwidth limit and target cache mode were changed
together, I cannot conclusively isolate their individual effects.

I have not repeated the failing conversion solely to test this distinction,
as the original behavior caused severe host responsiveness issues.

*Questions*

Would enabling -t none for LVM-thin destinations be appropriate?

Alternatively, would it be preferable to make the target cache mode
configurable for disk conversion operations?

I understand that the degraded RAID BBU and WriteThrough policy may
contribute to the observed behavior, and I cannot yet determine whether the
issue affects other hardware configurations.

I would appreciate feedback on the preferred approach. This would be my
first contribution to Proxmox VE. I would be happy to perform additional
tests, prepare a patch, or follow any guidance on the preferred approach.

Thank you for your time and for maintaining Proxmox VE.
Rafael Prazeres

^ permalink raw reply	[flat|nested] only message in thread

only message in thread, other threads:[~2026-10-28  7:41 UTC | newest]

Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-10-28  7:41 qemu-server: Severe I/O stalls moving VM disks from NFS to LVM-thin, resolved with -t none RAFAEL SILVA

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal