messages from 2026-10-02 09:36:27 to 2026-10-06 12:44:14 UTC [more...]
[PATCH manager] fix #4986: jobs: do not get stuck if the task log is missing
2026-10-06 12:41 UTC (2+ messages)
` applied: "
[PATCH-SERIES qemu-server v2 0/2] hotplug pending: use machine type from running instance to avoid mismatch
2026-10-06 12:33 UTC (6+ messages)
` [PATCH qemu-server v2 1/2] "
` [PATCH qemu-server v2 2/2] hotplug pending: only query machine type when actually required
` applied: [PATCH-SERIES qemu-server v2 0/2] hotplug pending: use machine type from running instance to avoid mismatch
[PATCH common/manager 0/2] fix #8006: acme: lifetime-based certificate renewal threshold
2026-10-06 12:31 UTC (3+ messages)
` [PATCH pve-common 1/2] certificate: add helpers for lifetime-based ACME renewal
` [PATCH pve-manager 2/2] fix #8006: api: acme: lifetime-based certificate renewal threshold
[RFC PATCH yew-widget-toolkit] widget: data table: implement auto column sizing based on sample records
2026-10-06 11:29 UTC (2+ messages)
` superseded: "
[PATCH yew-widget-toolkit v2] widget: data table: implement auto column sizing based on sample records
2026-10-06 11:28 UTC
[PATCH test-tools,e2e-tests 0/6] randomly select VMIDs for test
2026-10-06 10:50 UTC (4+ messages)
` [PATCH test-tools 1/6] runner: add vmid-range option for test guest VMIDs
[PATCH qemu-server] fix #4012: migrate: mention snapshots referencing a local ISO image
2026-10-06 10:00 UTC (2+ messages)
[PATCH widget-toolkit] fix #7586: notification: check names of matchers and targets in the UI
2026-10-06 9:54 UTC
[PATCH docs] fix #5371: user management: document the PAM service of the PAM realm
2026-10-06 9:23 UTC
[PATCH qemu-server] hotplug pending: use machine type from running instance to avoid mismatch
2026-10-06 9:00 UTC (2+ messages)
` superseded: "
[PATCH datacenter-manager v6 00/11] refactor and partially fix #7371
2026-10-06 8:59 UTC (13+ messages)
` [PATCH datacenter-manager v6 01/11] lib: api types: add new ResourceView type and move accessors there
` [PATCH datacenter-manager v6 02/11] lib: api types: resource: add 'node' helper to ResourceView
` [PATCH datacenter-manager v6 03/11] lib: api types: add guest specific getter "
` [PATCH datacenter-manager v6 04/11] ui: pve: factor out the pve-manager version extraction
` [PATCH datacenter-manager v6 05/11] ui: renderer: use ResourceView for rendering
` [PATCH datacenter-manager v6 06/11] ui: pve: tree: reuse `PveResource` for `PveTreeNode`
` [PATCH datacenter-manager v6 07/11] ui: pve: tree: render guest tags directly after their name
` [PATCH datacenter-manager v6 08/11] ui: pve: show ha maintenance mode for nodes
` [PATCH datacenter-manager v6 09/11] ui: pve: node selector: show maintenance badge with node name
` [PATCH datacenter-manager v6 10/11] ui: pve: node selector: sort memory columns by usage not by memory size
` [PATCH datacenter-manager v6 11/11] ui: pve: node: show ha maintenance badge
` applied: [PATCH datacenter-manager v6 00/11] refactor and partially fix #7371
[PATCH storage v3 0/4] add ZFS over NVMe/TCP storage plugin
2026-10-05 0:26 UTC (7+ messages)
` [PATCH storage v3 1/4] zfsnvme: "
` [PATCH storage v3 2/4] test: add zfsnvme plugin tests
` [PATCH storage v3 3/4] zfsnvme: fence target commands of abandoned transactions
` [PATCH storage v3 4/4] zfsnvme: wait up to 30 seconds for the shared storage lock
` [PATCH docs v3] storage: document ZFS over NVMe/TCP
` [PATCH manager v3] ui: storage: add ZFS over NVMe/TCP editor
[PATCH storage] fix #6405: disks: smart: parse ATA attributes with additional flags
2026-10-03 11:21 UTC
[RFC] WebRTC console for VMs via QEMU's D-Bus display
2026-10-01 15:10 UTC
[PATCH docs/manager/storage v12 0/6] fix #7339: lvmthick: add option to free storage for deleted VMs
2026-10-06 8:33 UTC (2+ messages)
[PATCH guest-common/manager v2 0/3] fix #5713: vzdump: add notification-mode none
2026-10-06 8:26 UTC (4+ messages)
[PATCH access-control] fix #5368: pam: say that a failed password change is about the host user
2026-10-06 8:21 UTC
[PATCH manager/guest-common/docs 0/3] fix #5990: vzdump: notes template: add pool variable
2026-10-06 7:50 UTC (4+ messages)
` [PATCH manager 1/3] "
` [PATCH guest-common 2/3] vzdump: notes template: mention pool variable in description
` [PATCH docs 3/3] vzdump: notes template: document pool variable
[PATCH manager] fix #8098: ui: ceph: osd: sort by name naturally
2026-10-06 7:20 UTC
[PATCH cluster/docs/manager/widget-toolkit v4 0/8] add warning messages for high token timeouts in clusters
2026-10-05 15:57 UTC (2+ messages)
[PATCH proxmox{,-backup,-datacenter-manager} v3 0/5] factor system report into shared crate
2026-10-05 14:50 UTC (2+ messages)
[PATCH many v6 00/18] add option to prevent suggesting previously used VMIDs
2026-10-05 14:50 UTC (7+ messages)
` [PATCH guest-common v6 07/18] guest id: keep used ID list below the pmxcfs file size limit
` superseded: [PATCH many v6 00/18] add option to prevent suggesting previously used VMIDs
[PATCH many v7 00/24] add option to prevent suggesting previously used VMIDs
2026-10-05 14:48 UTC (25+ messages)
` [PATCH cluster v7 01/24] cluster files: add virtual-guest/used-guest-ids
` [PATCH cluster v7 02/24] datacenter config: add unique subproperty to next-id
` [PATCH cluster v7 03/24] datacenter config: next-id: add enforce subproperty
` [PATCH guest-common v7 04/24] src/makefile: order files alphabetically
` [PATCH guest-common v7 05/24] add module to track previously used guest IDs
` [PATCH guest-common v7 06/24] tests: add tests for used guest ID tracking
` [PATCH guest-common v7 07/24] abstract config: register used guest ID when creating config
` [PATCH guest-common v7 08/24] guest id: keep used ID list below the pmxcfs file size limit
` [PATCH guest-common v7 09/24] tests: add tests for used-guest-ids max file size handling
` [PATCH guest-common v7 10/24] guest id: optionally enforce the next-id range and uniqueness
` [PATCH guest-common v7 11/24] guest id: add helper to check guest IDs against next-id enforcement
` [PATCH qemu-server v7 12/24] api: record VM ID as used on destruction and remote migration
` [PATCH qemu-server v7 13/24] api, remote migrate: exempt existing VMs from next-id enforcement
` [PATCH container v7 14/24] api: record CT ID as used on destruction and remote migration
` [PATCH container v7 15/24] api, migrate: exempt existing CTs from next-id enforcement
` [PATCH manager v7 16/24] ui: guest ID selector: rename exists flag to rejected
` [PATCH manager v7 17/24] ui: guest ID selector: show the error returned by nextid
` [PATCH manager v7 18/24] fix #4369: api: optionally only suggest unique IDs
` [PATCH manager v7 19/24] ui: dc options: rename VMID to guest ID
` [PATCH manager v7 20/24] fix #4369: ui: dc options: add option for unique VM/CT IDs
` [PATCH manager v7 21/24] api: nextid: reject IDs forbidden by next-id enforcement
` [PATCH manager v7 22/24] ui: dc options: add option to enforce next free guest ID settings
` [PATCH docs v7 23/24] pmxcfs: files: add virtual-guest/used-guest-ids
` [PATCH docs v7 24/24] pvecm: next-id: document unique and enforce options
[PATCH v2 0/16] Support for custom EFI firmware
2026-10-05 14:37 UTC (20+ messages)
` [PATCH v2 pve-storage 1/16] plugin: add efi-firmware content type
` [PATCH v2 pve-storage 2/16] test: get_subdir: cover the "
` [PATCH v2 pve-storage 3/16] plugins: allow the efi-firmware content type on file based storages
` [PATCH v2 pve-storage 4/16] api: status: support efi-firmware in upload and download-url
` [PATCH v2 pve-storage 5/16] test: volume access: cover efi-firmware volumes
` [PATCH v2 pve-storage 6/16] test: list volumes: "
` [PATCH v2 qemu-server 07/16] config: add the efi-firmware option
` [PATCH v2 qemu-server 08/16] api: allow setting "
` [PATCH v2 qemu-server 09/16] ovmf: use a custom firmware image if configured
[PATCH proxmox-offline-mirror] fix #7762: wizard: add PDM support
2026-10-05 14:32 UTC (2+ messages)
[PATCH pve-guest-common] tunnel: websocket: prepend api token name when missing
2026-10-05 14:14 UTC (3+ messages)
[PATCH pve-manager v2 0/2] fix #7794: ui: dc summary: add per-node VM/CT count columns
2026-10-05 14:12 UTC (2+ messages)
[PATCH qemu-server v2 0/5] remote migration: extract preconditions and add check endpoint
2026-10-05 14:03 UTC (2+ messages)
[PATCH pve-network] sdn: zones: vxlan: restore the flood entries after an FRR reload
2026-10-05 13:32 UTC (5+ messages)
[PATCH proxmox{,-backup} 00/14] fix #7904: Implement Enable checkboxes for all jobs
2026-10-05 13:12 UTC (2+ messages)
[PATCH pve-kernel] pick proposed fix for bnxt regression in 7.0.14-20+
2026-10-05 11:47 UTC
[PATCH pve-manager] fix typo risc64 => riscv64
2026-10-05 11:07 UTC (2+ messages)
[PATCH storage] plugins: better document how volname_for_format() validates the name
2026-10-05 11:04 UTC
[PATCH proxmox-ve-rs] proxmox-frr: add missing build-deps proxmox-frr-templates
2026-10-05 11:05 UTC (3+ messages)
` applied: "
[PATCH pve-storage 0/2] fix #7360: esxi: write password file as
2026-10-05 10:55 UTC (3+ messages)
` [PATCH pve-storage 1/2] fix #7360: esxi: store password file as utf-8
` [PATCH pve-storage 2/2] esxi: rewrite non-UTF-8 password files
[RFC PATCH datacenter-manager 1/2] ui: pve: tree: render guest tags directly after their name
2026-10-05 11:02 UTC (5+ messages)
` [RFC PATCH datacenter-manager 2/2] ui: pve: tree: size action column better
` superseded: [RFC PATCH datacenter-manager 1/2] ui: pve: tree: render guest tags directly after their name
[PATCH datacenter-manager v5 00/10] refactor and partially fix #7371
2026-10-05 11:01 UTC (14+ messages)
` [PATCH datacenter-manager v5 01/10] lib: api types: add new ResourceView type and move accessors there
` [PATCH datacenter-manager v5 02/10] lib: api types: resource: add 'node' helper to ResourceView
` [PATCH datacenter-manager v5 03/10] lib: api types: add guest specific getter "
` [PATCH datacenter-manager v5 04/10] ui: pve: factor out the pve-manager version extraction
` [PATCH datacenter-manager v5 05/10] ui: renderer: use ResourceView for rendering
` [PATCH datacenter-manager v5 06/10] ui: pve: tree: reuse `PveResource` for `PveTreeNode`
` [PATCH datacenter-manager v5 07/10] ui: pve: show ha maintenance mode for nodes
` [PATCH datacenter-manager v5 08/10] ui: pve: node selector: show maintenance badge with node name
` [PATCH datacenter-manager v5 09/10] ui: pve: node selector: sort memory columns by usage not by memory size
` [PATCH datacenter-manager v5 10/10] ui: pve: node: show ha maintenance badge
` superseded: [PATCH datacenter-manager v5 00/10] refactor and partially fix #7371
[PATCH storage v2 0/7] add native ZFS over NVMe/TCP backend
2026-10-05 0:27 UTC (3+ messages)
[PATCH storage] fix #6915: lvmthin: leave room for repair
2026-10-04 19:33 UTC (2+ messages)
` applied: "
[PATCH storage] fix #7295: lvm plugin: rollback: keep original volume when allocation fails and saferemove is used
2026-10-04 19:33 UTC (2+ messages)
` applied: "
[PATCH storage] lvm plugin: snapshot: don't quietly ignore failure to rename back to original
2026-10-04 19:33 UTC (2+ messages)
` applied: "
[PATCH storage 0/3] generalize volname_for_format across storage plugins
2026-10-04 19:33 UTC (2+ messages)
` applied: "
[PATCH pve-storage] esxi plugin: keep uuid inside vm the same as in esxi
2026-10-04 19:33 UTC (2+ messages)
` applied: "
[PATCH manager] fix #7684: ui: backup job detail: allow sorting guests by inclusion status
2026-10-04 17:35 UTC
[PATCH manager] fix #7178: pve8to9: detect qcow2 TPM state volumes containing raw data
2026-10-04 17:05 UTC
[PATCH manager] ui: qemu pci edit: remove the default PCI domain again before saving
2026-10-04 16:34 UTC
[PATCH manager/docs 0/2] fix #7649: active directory realm: expose and document user attribute name
2026-10-04 16:03 UTC (3+ messages)
` [PATCH manager 1/2] fix #7649: ui: active directory realm: expose user attribute name option
` [PATCH docs 2/2] pveum: active directory: document "
[PATCH docs] fix #5273: pvecm: qdevice: note to not run qnetd on the cluster itself
2026-10-04 15:33 UTC
[PATCH access-control] fix #6429: openid: use the updated user config for the login permissions
2026-10-04 15:02 UTC
[PATCH common 0/2] cli formatter: fix double UTF-8 encoding of YAML
2026-10-04 14:32 UTC (3+ messages)
` [PATCH common 1/2] fix #6305: cli formatter: avoid encoding YAML output twice
` [PATCH common 2/2] cli formatter: decode the output of the yaml renderer
[PATCH manager] fix #6009: ui: drop the 128 TiB limit for disk sizes
2026-10-04 14:00 UTC
[PATCH qemu-server] fix #7525: vga: allow setting the number of outputs for VirtIO GPU
2026-10-04 13:29 UTC
[PATCH proxmox-acme] fix #7155: proxmox-acme: support upper-hex mode of _url_encode
2026-10-04 12:59 UTC
[PATCH docs] fix #7560: user management: privileges: document Sys.AccessNetwork
2026-10-04 12:28 UTC
[PATCH manager/widget-toolkit 0/2] fix #4588: acme: allow setting the alias of DNS domains
2026-10-04 11:58 UTC (3+ messages)
` [PATCH manager 1/2] fix #4588: ui: "
` [PATCH widget-toolkit 2/2] acme: domain edit: "
[PATCH manager] fix #5725: pvenode: acme: add options for external account binding
2026-10-04 11:27 UTC
[PATCH manager] fix #5352: ui: sdn: status: make the list scrollable
2026-10-04 10:57 UTC
[PATCH manager] fix #5798: ui: qemu pci edit: fix warning for shared IOMMU groups
2026-10-03 15:07 UTC
[PATCH storage] fix #6184: import: ovf: add CD drives
2026-10-03 13:28 UTC
[PATCH cluster] fix #5794: cluster join: check that the interfaces of the links are up
2026-10-03 13:16 UTC
[PATCH storage 0/3] api: disks: zfs: fix error counters and in-use spares in pool details
2026-10-03 12:49 UTC (4+ messages)
` [PATCH storage 1/3] test: add tests for zpool status parsing of the ZFS disk API
` [PATCH storage 2/3] fix #6640, #6938: api: disks: zfs: return exact error counters
` [PATCH storage 3/3] fix #6389: api: disks: zfs: parse the message of hot spares in use
[PATCH storage] fix #6441: btrfs: fix cloning templates with non-raw disk images
2026-10-03 12:15 UTC
[PATCH datacenter-manager v4 00/10] refactor and partially fix #7371
2026-10-02 14:15 UTC (2+ messages)
` superseded: "
[PATCH docs/guest-common/qemu-server v5 0/9] add new pci passthrough specific hookscript phase
2026-10-02 13:39 UTC (2+ messages)
[PATCH pve_flutter_frontend] chore: bump version to 1.9.6(53)
2026-10-02 12:52 UTC
[PATCH proxmox-backup] fix #6251: api: Remove running tasks from errors output
2026-10-02 12:34 UTC (2+ messages)
` applied: "
[PATCH proxmox-backup] tape: labeling: improve error message for tapes with existing data
2026-10-02 12:34 UTC (2+ messages)
` applied: "
[PATCH proxmox-backup] fix #8003: sync: pull: log skipped chunk reuse for corrupt manifests
2026-10-02 12:34 UTC (2+ messages)
` applied: "
[PATCH pve-docs 1/1] network/sdn: update and clean up vlan information
2026-10-02 12:32 UTC (3+ messages)
[PATCH proxmox] fix #7723: network-api: avoid overwriting existing inet6 family method
2026-10-02 12:12 UTC (2+ messages)
[PATCH datacenter-manager/yew-widget-toolkit v2 0/3] ui: persist the main menus expanded state
2026-10-02 11:53 UTC (2+ messages)
[RFC datacenter-manager/proxmox v2 0/4] log: allow finegrained control logging levels
2026-10-02 10:59 UTC (6+ messages)
[PATCH container 1/2] pct: Remove experimental state from mknod
2026-10-02 10:36 UTC (2+ messages)
` [PATCH manager 2/2] lxc: features: Remove Experimental suffix from Device Nodes option
[PATCH pve-manager v3 0/2] fix #8031: write APT proxy config on http_proxy change
2026-10-02 10:32 UTC (3+ messages)
` [PATCH pve-manager v3 2/2] "
[PATCH datacenter-manager/proxmox v5 00/21] inject application context via API macro for easier integration testing
2026-10-02 9:46 UTC (2+ messages)
` superseded: "
[PATCH datacenter-manager/proxmox v6 00/21] inject application context via API macro for easier integration testing
2026-10-02 9:36 UTC (20+ messages)
` [PATCH proxmox v6 03/21] api-macro: support #[state] attribute for state injection
` [PATCH proxmox v6 04/21] product-config: add ProductConfig type
` [PATCH datacenter-manager v6 05/21] context: promote context to a dir-style module
` [PATCH datacenter-manager v6 06/21] pdm-config: remotes: rename trait methods to read/write/lock
` [PATCH datacenter-manager v6 07/21] pdm-config: subscriptions: "
` [PATCH datacenter-manager v6 08/21] context: introduce a ContextFactory to build application context
` [PATCH datacenter-manager v6 09/21] context: establish PdmApplication object
` [PATCH datacenter-manager v6 10/21] context: register PdmApplication in router
` [PATCH datacenter-manager v6 11/21] connection: use client factory from PdmApplication handle
` [PATCH datacenter-manager v6 12/21] remote iterator: pass remote config reader explicitly
` [PATCH datacenter-manager v6 13/21] parallel fetcher: pass arguments to closure in a single type
` [PATCH datacenter-manager v6 14/21] server: migrate existing ParallelFetcher users to use PdmApplication
` [PATCH datacenter-manager v6 15/21] tests: add helpers for building API-handler-level integration tests
` [PATCH datacenter-manager v6 16/21] tests: add example tests for SDN API routes
` [PATCH datacenter-manager v6 17/21] api-cache: add wrapper type
` [PATCH datacenter-manager v6 18/21] context: provide api-cache on the app object
` [PATCH datacenter-manager v6 19/21] api: subscriptions: use PdmApplication instead of globals
` [PATCH datacenter-manager v6 20/21] pdm-config: subscriptions: drop unused accessor functions
` [PATCH datacenter-manager v6 21/21] tests: add example tests for remote subscription management
page: next (older) | prev (newer) | latest
- recent:[subjects (threaded)|topics (new)|topics (active)]
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.