Subject: [PATCH v4 docs 23/36] storage: document the cluster-wide multipath management
Date: Fri, 13 Nov 2026 04:00:41 +0100	[thread overview]
Message-ID: <20261113030146.1559030-24-t.lamprecht@proxmox.com> (raw)
In-Reply-To: <20261113030146.1559030-1-t.lamprecht@proxmox.com>

Add a chapter for multipath on iSCSI and Fibre Channel SANs, written
around the tasks an admin has: prerequisites, setting up shared LVM
with the guided setup or by hand, adding, growing and removing a LUN,
reading the states during a path failure, array-specific settings and
moving over from a hand-made multipath.conf.

Removing a LUN stays a manual procedure, as Proxmox VE never removes a
WWID or a map by itself, so the chapter spells it out including how to
get out of queued I/O.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
---
 pmxcfs.adoc                  |   2 +
 pve-storage-iscsi.adoc       |  11 ++
 pve-storage-iscsidirect.adoc |   2 +-
 pve-storage-lvm.adoc         |   3 +
 pve-storage-multipath.adoc   | 260 +++++++++++++++++++++++++++++++++++
 pvesm.adoc                   |  18 ++-
 6 files changed, 290 insertions(+), 6 deletions(-)
 create mode 100644 pve-storage-multipath.adoc

diff --git a/pmxcfs.adoc b/pmxcfs.adoc
index 4a334fd..9a1dbd0 100644
--- a/pmxcfs.adoc
+++ b/pmxcfs.adoc
@@ -105,6 +105,8 @@ Files
 |`ha/manager_status`                    | JSON-formatted information regarding HA services on the cluster
 |`ha/resources.cfg`                     | Resources managed by high availability, and their current state
 |`ha/rules.cfg`                         | Rules putting constraints on the HA manager's scheduling of HA resources
+|`multipath-overrides.conf`             | Hardware-specific multipath settings, in `multipath.conf` format, applied on all nodes
+|`multipath.cfg`                        | {pve} cluster-wide multipath configuration (LUN entries)
 |`nodes/<NAME>/config`                  | Node-specific configuration
 |`nodes/<NAME>/lxc/<VMID>.conf`         | VM configuration data for LXC containers
 |`nodes/<NAME>/openvz/`                 | Prior to {pve} 4.0, used for container configuration data (deprecated, removed soon)
diff --git a/pve-storage-iscsi.adoc b/pve-storage-iscsi.adoc
index a02ed46..f8b3a76 100644
--- a/pve-storage-iscsi.adoc
+++ b/pve-storage-iscsi.adoc
@@ -23,6 +23,10 @@ resources.
 
 Low-level iscsi management task can be done using the `iscsiadm` tool.
 
+TIP: To set up shared LVM on a LUN of an iSCSI target, use the guided setup
+under *Datacenter -> Storage -> SAN* in the web UI, see
+xref:storage_multipath_setup[Multipath].
+
 
 Configuration
 ~~~~~~~~~~~~~
@@ -38,6 +42,13 @@ target::
 
 iSCSI target.
 
+multipath::
+
+Combine the paths to each LUN of the target into one `dm-multipath` map on every
+node the storage is enabled on, and monitor the maps cluster-wide. A shared LVM
+storage on a target with several portals needs this option. See
+xref:storage_multipath[Multipath].
+
 
 .Configuration Example (`/etc/pve/storage.cfg`)
 ----
diff --git a/pve-storage-iscsidirect.adoc b/pve-storage-iscsidirect.adoc
index ae722e8..822e9c7 100644
--- a/pve-storage-iscsidirect.adoc
+++ b/pve-storage-iscsidirect.adoc
@@ -21,7 +21,7 @@ Configuration
 ~~~~~~~~~~~~~
 
 The user mode iSCSI backend uses the same configuration options as the
-Open-iSCSI backend.
+Open-iSCSI backend, except for `multipath`.
 
 .Configuration Example (`/etc/pve/storage.cfg`)
 ----
diff --git a/pve-storage-lvm.adoc b/pve-storage-lvm.adoc
index 5b88151..3813a06 100644
--- a/pve-storage-lvm.adoc
+++ b/pve-storage-lvm.adoc
@@ -121,6 +121,9 @@ A benefit of LVM is that it can be used with shared storage.
 For example, an iSCSI LUN. The backend implements proper cluster-wide locking if
 the storage is marked as shared in the configuration.
 
+TIP: The guided setup under *Datacenter -> Storage -> SAN* in the web UI creates
+a shared LVM storage on a SAN LUN, see xref:storage_multipath_setup[Multipath].
+
 NOTE: If you extend a shared volume group onto another device on one node, the
 other nodes may only see the added physical volume after LVM has scanned their
 devices again, for example with `pvscan --cache`. This command also resets the
diff --git a/pve-storage-multipath.adoc b/pve-storage-multipath.adoc
new file mode 100644
index 0000000..d4503a7
--- /dev/null
+++ b/pve-storage-multipath.adoc
@@ -0,0 +1,260 @@
+[[storage_multipath]]
+Multipath
+---------
+ifdef::wiki[]
+:pve-toplevel:
+:title: Storage: Multipath
+endif::wiki[]
+
+Use multipath for shared LVM on an iSCSI or Fibre Channel SAN with redundant
+connections. Device-mapper multipath combines the paths to a LUN into one block
+device, called a map, so I/O can continue when a path fails. Its World Wide
+Identifier (WWID) identifies the same LUN on every node.
+
+{pve} configures maps cluster-wide and shows their state under *Datacenter ->
+Storage -> SAN*. An iSCSI storage with *Multipath* enabled requests maps for its
+LUNs; Fibre Channel LUNs need entries in `/etc/pve/multipath.cfg`. NVMe
+namespaces use kernel-native multipath instead; the procedures below cover SCSI
+LUNs.
+
+Prerequisites
+~~~~~~~~~~~~~
+
+. Upgrade all nodes before enabling cluster-wide multipath management.
+. Install `multipath-tools` on every participating node. The
+  `libpve-storage-perl` package recommends it, but installations without
+  recommended packages need it added separately. A node without it shows
+  *Multipath unavailable* with the reason under *Datacenter -> Storage -> SAN*.
+  Plain iSCSI and LVM without the multipath option still work without it.
+. Allow each node's iSCSI initiator name on the array; the names are shown under
+  *Datacenter -> Storage -> SAN* and in the guided setup. Install `open-iscsi`
+  if needed.
+  For Fibre Channel, configure zoning and LUN masking for the WWPNs of each
+  node's HBA ports, which `cat /sys/class/fc_host/host*/port_name` lists.
+. Present the same empty LUN to all intended nodes over redundant paths. A node
+  does not scan for a Fibre Channel LUN that is mapped to it later, so rescan
+  the Fibre Channel hosts on each node:
++
+----
+# for host in /sys/class/fc_host/host*; do echo '- - -' > /sys/class/scsi_host/${host##*/}/scan; done
+----
++
+If the LUN still does not show up, check the target ports of the array on the
+node. This lists the WWPN, state and roles of each remote port; those of the
+array need the state `Online` and the role `FCP Target`. A `Blocked` port needs
+its connection restored before a rescan can reach it:
++
+----
+# for port in /sys/class/fc_remote_ports/rport-*; do echo $(cat $port/{port_name,port_state,roles}); done
+----
+
+[[storage_multipath_setup]]
+Setting Up Shared LVM
+~~~~~~~~~~~~~~~~~~~~
+
+. Open *Datacenter -> Storage -> SAN* in the web UI on a node that can access
+  the LUN and select *Add Storage -> LVM on iSCSI* or *LVM on Fibre Channel*.
+. For iSCSI, enter a portal, select the target and name the connection storage.
+  This storage connects to the target with `content none` and *Multipath*
+  enabled, while the LVM storage manages guest disks. Continuing creates or
+  reuses the connection storage before you select a LUN.
+. Select the LUN, choose the storage ID and volume group, then confirm. For
+  Fibre Channel, the setup adds the multipath entry of the LUN if it has none.
+  An entry it adds expects as many paths as the map has on the node serving
+  the web UI when it appears, if that is at least two; existing entries and
+  maps stay as they are. Set *Expected Paths* in the entry if it is missing or
+  does not match the intended topology, for example because a fabric was down
+  at that time or nodes have different path counts.
+  Leave *Nodes* empty for all nodes. Virtual machines on the storage can only
+  have snapshots with *Allow Snapshots as Volume-Chain*, a technology preview
+  that applies to disks created after it is set; see
+  xref:pvesm_lvm_config[LVM configuration].
+. Check the state of the LUN on each node of the storage, which the setup
+  shows once the storage is added. Before that, only the node serving the web
+  UI looked at the LUN; the LUN list names it as *Scan node*. The other nodes
+  set the LUN up with their next status updates and show *Pending* during the
+  first minute. For a node that stays *Missing*, check its access to the LUN
+  on the array before placing guests on the storage. *OK (1 path)* means that
+  the node reaches the LUN over a single path. The *State* column of the view
+  shows the same later.
+
+A LUN that a storage uses cannot be selected, and the setup refuses a LUN that
+contains data. To reuse such a LUN, first stop all its users on all hosts and
+remove its storage references, then use *Wipe* under *Node -> SAN* as
+`root@pam`. This destroys its data. The usage shown for a LUN is cached per
+node, so other nodes can still show the old content after a wipe. If setup
+fails, check the error, the node's task log and *Datacenter -> Storage* before
+retrying; closing the dialog does not undo changes.
+
+The dialogs under *Datacenter -> Storage -> Add* can do the same for iSCSI in
+two steps: add an *iSCSI* storage with *Multipath* enabled and *Use LUNs
+directly* cleared, then an *LVM* storage with it as *Base storage* and the LUN
+as *Base volume*. Selecting a base storage enables *Shared*; keep it enabled.
+
+To set up iSCSI by hand, run these commands on a node with access to the target:
+
+----
+# pvesm add iscsi <connection> --portal <portal> --target <iqn> --content none --multipath 1
+# pvesm list <connection> --content images
+# pvesm add lvm <storage> --vgname <vg> --base <volume-id> --shared 1
+----
+
+Use the complete volume ID from the listing, including the connection storage
+prefix and the `dm-uuid-mpath-<wwid>` suffix. Adding the LVM storage creates the
+volume group. Keep its base volume: it connects the target before LVM
+activation.
+
+For Fibre Channel, add an entry with the number of paths each node should
+have, wait for the scan to show a by-id path with `dm-uuid-mpath-<wwid>`, then
+create the volume group and shared storage:
+
+----
+# pvesh create /cluster/multipath/wwid --wwid <wwid> --paths-expected <paths>
+# pvesm scan san-luns --output-format json
+# pvesh create /nodes/<node>/disks/lvm --name <storage> \
+    --device /dev/disk/by-id/dm-uuid-mpath-<wwid> --add_storage 1
+----
+
+These examples allow all nodes. For a subset, set `--nodes <nodes>` on the
+entry or iSCSI storage and on the LVM storage (`pvesm set <storage> --nodes
+<nodes>`), using a comma-separated list. `pvesh` waits for the creation task;
+check its output for errors before using the storage.
+
+Adding Another LUN
+~~~~~~~~~~~~~~~~~~
+
+. Present the new LUN to the same nodes on the array. Enabled iSCSI storages
+  rescan their sessions automatically; for Fibre Channel, rescan the hosts as
+  shown in the prerequisites.
+. Run the guided setup again. For iSCSI, select the same target to reuse its
+  connection storage. If it lacks *Multipath*, enable that option in its edit
+  dialog first, observing the migration advice below.
+. Select the new LUN and create a separate LVM storage. By hand, repeat the
+  iSCSI listing and LVM command above, or the Fibre Channel procedure.
+
+[[storage_multipath_grow]]
+Growing a LUN
+~~~~~~~~~~~~~
+
+. Grow the LUN on the array. Never shrink a LUN in use.
+. Wait for the iSCSI session rescan, or rescan each SCSI path on every Fibre
+  Channel node with `echo 1 > /sys/block/<path>/device/rescan`, where `<path>`
+  is a member device such as `sdc`, not the map.
+. Check the map size on every node with `multipath -ll <wwid>` or under
+  *Node -> SAN*. The generated configuration sets `auto_resize grow_only`:
+  the map grows once all its paths report the new size. If necessary, run
+  `multipathd resize map <map>` after all paths have grown.
+. Run `pvresize /dev/disk/by-id/dm-uuid-mpath-<wwid>` on one node only, after
+  every node's map has grown. A smaller map cannot access the added space.
+
+[[storage_multipath_remove]]
+Removing a LUN
+~~~~~~~~~~~~~~
+
+{pve} never flushes maps or removes WWIDs from `/etc/multipath/wwids`.
+Removing a configuration entry is not enough. A map that queues I/O without
+paths can block guests and LVM commands, so disable queueing before unmapping:
+
+. Stop all users of the LUN on all hosts, or move their data elsewhere. Remove
+  the LVM storage with `pvesm remove <storage>` and deactivate its volume group
+  on every node with `vgchange -an <vg>`. Neither command erases the data.
+. Set an existing entry to fail I/O with
+  `pvesh set /cluster/multipath/wwid/<wwid> --no-path-retry fail`.
+  If none exists, create one with
+  `pvesh create /cluster/multipath/wwid --wwid <wwid> --no-path-retry fail`.
+  Add `--nodes <nodes>` if only a subset of nodes sees the LUN.
+. Wait until `multipath -ll <wwid>` on every participating node no longer lists
+  `queue_if_no_path` in the map's features. Wait for offline nodes to return.
+  Record the map name and member devices, and each member's identifier from
+  `/sys/block/<path>/device/wwid`.
+. Unmap the LUN on the array.
+. On every node, flush the map with `multipath -f <map>`. If it is busy, retry
+  after a few seconds; if it stays busy, find and stop its remaining users. Do
+  not force removal. For each recorded path,
+  check that its identifier is unchanged, then delete it with
+  `echo 1 > /sys/block/<path>/device/delete`. Skip paths already gone; stop if
+  an identifier changed.
+. Remove the explicit entry with `pvesh delete /cluster/multipath/wwid/<wwid>`.
+  Removing it earlier makes the nodes apply the default retry policy of the
+  array again, which can queue I/O on a map that is not flushed yet and block
+  whatever opens it.
+. On every node, wait until its next status update has removed the WWID from
+  `/etc/multipath/conf.d/pve-aliases.conf`, which takes about ten seconds, then
+  run `multipath -w <wwid>` to remove it from the allow-list. Running it before
+  that update can let the update add the WWID again. Check that
+  `grep -c '^/<wwid>/$' /etc/multipath/wwids` prints 0, and again after the
+  next status update.
+
+If the LUN was already unmapped and I/O is stuck, run
+`multipathd disablequeueing map <map>` on each affected node, then continue
+with the removal procedure.
+
+[[storage_multipath_disconnect]]
+Removing an iSCSI connection storage does not log out its sessions. Keep it
+while other LUNs of the target are in use; session maintenance is done with
+`iscsiadm`, not the read-only *Node -> SAN -> iSCSI* view.
+
+Checking Path Failures
+~~~~~~~~~~~~~~~~~~~~~
+
+*Datacenter -> Storage -> SAN* shows node availability, configuration errors
+and LUN states. The *State* of a LUN is the worst one among its nodes and names
+them if they are only some of the nodes. Hover over it for the states and path
+counts of all nodes. *Multipath* describes how the map is managed, not its
+health: by an explicit entry, by the storage that requests it, or *Unmanaged*
+for a map that {pve} did not set up. Under *Node -> SAN*, expand the LUN to
+inspect individual paths. *Node -> SAN -> iSCSI* shows targets and sessions.
+
+*Optimal*:: All known paths are usable and no expected path is missing.
+*OK (1 path)*:: The only path is usable, and there is no other path to fail
+over to. The API reports this as `optimal` with one path.
+*Degraded*:: Some paths are unusable or fewer paths exist than expected.
+*Failed*:: No usable path remains; I/O queues or fails according to the retry
+policy.
+*Missing*:: A node with a current report is expected to have the LUN but does
+not.
+*Unknown*:: No usable current observation is available for that node.
+
+During a path failure, inspect the degraded LUN's paths and restore the failed
+connection. The state returns to *Optimal* when the paths recover. Check node
+availability too: unknown observations do not worsen a known LUN state.
+
+An iSCSI storage expects one path per portal. For a Fibre Channel LUN, set
+*Expected Paths* in its multipath entry, as the guided setup does. Without it,
+a node only shows fewer paths than it should have while the lost ones are
+still listed. Depending on the settings for the array, the kernel removes a
+path that stays down longer than `dev_loss_tmo`, and the map then shows
+*Optimal* with fewer paths, or *OK (1 path)* for the last one.
+
+[[storage_multipath_config]]
+Array Settings and Existing Configurations
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Use the built-in device profiles unless the array vendor requires changes.
+*Edit Overrides* under *Datacenter -> Storage -> SAN* edits
+`/etc/pve/multipath-overrides.conf` for all nodes. For example, to set a retry
+count for one array model (replace the vendor and product expressions):
+
+----
+devices {
+    device {
+        vendor "<vendor>"
+        product "<product>"
+        no_path_retry 12
+    }
+}
+----
+
+To move from a hand-made `/etc/multipath.conf`:
+
+. Back up the local configuration on every node. Move shared array settings to
+  the overrides file; add WWID entries under *Datacenter -> Storage -> SAN* for
+  Fibre Channel LUNs or per-LUN aliases and `no-path-retry` settings.
+. Enable *Multipath* on existing iSCSI storages. Keep existing LVM base volumes.
+  Check `multipathd show config` on every node before removing duplicate local
+  settings. Do not edit the generated `/etc/multipath/conf.d/pve-*.conf` files.
+. Check active volume dependencies with `lsblk` on each node. Enabling multipath
+  does not move active volumes off individual paths. Stop and restart affected
+  guests, or migrate them away and back, before relying on path redundancy.
+  Keep LVM component detection enabled and follow the
+  xref:storage_lvm[shared LVM autoactivation guidance].
diff --git a/pvesm.adoc b/pvesm.adoc
index 5bd24b2..5668a41 100644
--- a/pvesm.adoc
+++ b/pvesm.adoc
@@ -96,11 +96,10 @@ TiB sized), these operations may take several minutes, or in extreme cases, even
 hours. If your setup is affected, create and remove snapshots while the VM is
 shut down, expecting a long task duration.
 
-^3^: With iSCSI, FibreChannel (FC), or SAS block storage as shared storage in a
-cluster, LVM is used to split the LUN into virtual disks. The
-https://pve.proxmox.com/wiki/Multipath[Multipath Guide] explains how to
-configure it in a cluster, including multipathing which is usually a
-requirement in these scenarios.
+^3^: With iSCSI, Fibre Channel (FC), or SAS block storage as shared storage in
+a cluster, LVM is used to split the LUN into virtual disks. A LUN is usually
+reachable over several paths; xref:storage_multipath[Multipath] describes how
+{pve} manages them in a cluster.
 
 ^4^: Since {pve} 9, snapshots as a volume chain have been available for VMs.
 These snapshots use separate volumes for the snapshot data and layer them.  For
@@ -153,6 +152,11 @@ also useful for local storage types. In this case such local storage
 is available on all nodes, but it is physically different and can have
 totally different content.
 
+Add storage under *Datacenter -> Storage -> Add* in the web UI. For shared LVM
+on a xref:storage_multipath_setup[SAN LUN], use the guided setup under
+*Datacenter -> Storage -> SAN -> Add Storage* instead. It creates the storages
+that are needed and enables multipath for the LUN.
+
 
 Storage Pools
 ~~~~~~~~~~~~~
@@ -421,6 +425,8 @@ See Also
 
 * link:/wiki/Storage:_iSCSI[Storage: iSCSI]
 
+* link:/wiki/Storage:_Multipath[Storage: Multipath]
+
 * link:/wiki/Storage:_LVM[Storage: LVM]
 
 * link:/wiki/Storage:_LVM_Thin[Storage: LVM Thin]
@@ -463,6 +469,8 @@ include::pve-storage-iscsi.adoc[]
 
 include::pve-storage-iscsidirect.adoc[]
 
+include::pve-storage-multipath.adoc[]
+
 include::pve-storage-rbd.adoc[]
 
 include::pve-storage-cephfs.adoc[]




  parent reply	other threads:[~2026-11-13  3:19 UTC|newest]

Thread overview: 38+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-11-13  3:00 [PATCH v4 cluster,storage,docs,manager 00/36] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 cluster 01/36] cfs: observe the multipath configuration files Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 02/36] diskmanage: collect disk transport type from lsblk Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 03/36] diskmanage: qualify NVMe over fabrics transport Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 04/36] diskmanage: optionally include iSCSI session devices in disk enumeration Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 05/36] diskmanage: collect native NVMe multipath path state Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 06/36] iscsi: factor out session device map from device list Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 07/36] multipath: add a library around multipathd Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 08/36] diskmanage: add helper to list multipath devices Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 09/36] multipath: add a cluster-wide configuration Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 10/36] iscsi: add an option to manage storage LUNs with multipath Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 11/36] lvm: activate a missing base volume before using the volume group Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 12/36] multipath: apply the configuration on every node Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 13/36] multipath: publish per-node status Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 14/36] api: add endpoints for the cluster-wide multipath configuration Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 15/36] api: multipath: add the cluster-wide health status Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 16/36] api: scan: add a SAN LUN inventory Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 17/36] pvesm: expose the " Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 18/36] api: add node-level iSCSI status Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 19/36] disks: lvm: drop unused imports Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 20/36] disks: lvm: allow volume groups on SAN LUNs and multipath maps Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 21/36] disks: lvm: refuse to destroy the volume group of a shared storage Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 storage 22/36] disks: allow wiping a SAN LUN that no storage uses Thomas Lamprecht
2026-11-13  3:00 ` Thomas Lamprecht [this message]
2026-11-13  3:00 ` [PATCH v4 manager 24/36] pvestatd: apply the multipath configuration and report the node status Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 25/36] report: add the managed multipath configuration Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 26/36] api: cluster: add the multipath endpoints Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 27/36] api: nodes: expose the iSCSI status Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 28/36] ui: dc: add a SAN view Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 29/36] ui: storage: iscsi: add the multipath option Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 30/36] ui: lvm: enable shared when a base storage is selected Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 31/36] ui: node: add SAN LUNs panel Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 32/36] ui: node: san: wipe a LUN that no storage uses Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 33/36] ui: node: san: show iSCSI targets and sessions Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 34/36] ui: dc: san: add a guided setup for shared LVM on iSCSI Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 35/36] ui: dc: san: add a guided setup for shared LVM on Fibre Channel Thomas Lamprecht
2026-11-13  3:00 ` [PATCH v4 manager 36/36] ui: storage: point the iSCSI and LVM add dialogs to the SAN view Thomas Lamprecht
2026-11-16  1:28 ` superseded: [PATCH v4 cluster,storage,docs,manager 00/36] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM Thomas Lamprecht

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20261113030146.1559030-24-t.lamprecht@proxmox.com \
    --to=t.lamprecht@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal