  To: pve-devel

While not a dedicated storage plugin, it is possible to use FC and SAS
attached block storage.

Make it clear that it works and can be used with the snapshots as a
volume chain feature as it needs LVM on top.

Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
---
 pvesm.adoc | 7 +++++++
 1 file changed, 7 insertions(+)

diff --git a/pvesm.adoc b/pvesm.adoc
index 97feca0..b43ca42 100644
--- a/pvesm.adoc
+++ b/pvesm.adoc
@@ -79,6 +79,7 @@ nodes that can be accessed as RBD (RADOS Block Device).
 |LVM-thin       |lvmthin     |block  |no    |yes      |yes
 |iSCSI/kernel   |iscsi       |block  |yes   |no       |yes
 |iSCSI/libiscsi |iscsidirect |block  |yes   |no       |yes
+|FC/SAS         |native^6^   |block  |yes   |yes^4^   |yes
 |Ceph/RBD       |rbd         |block  |yes   |yes      |yes
 |ZFS over iSCSI |zfs         |block  |yes   |yes      |yes
 |========================================================================
@@ -105,6 +106,12 @@ xref:pvesm_lvm_config[LVM configuration] section.
 
 ^5^ Technology preview with best-effort support.
 
+^6^ Fibre Channel (FC) and SAS block storage is handled directly by the host
+without a dedicated storage plugin. The
+https://pve.proxmox.com/wiki/Multipath[Multipath Guide] explains how to set it
+up in a cluster.
+
+
 Thin Provisioning
 ~~~~~~~~~~~~~~~~~
 
-- 
2.47.3





^ permalink raw reply related	[flat|nested] 5+ messages in thread

end of thread, other threads:[~2026-07-02 13:55 UTC | newest]

Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-07-02 11:08 [PATCH docs 1/2] pvesm: mention FC/SAS in the storage overview Aaron Lauterer
2026-07-02 11:08 ` [PATCH docs 2/2] pvesm: update features for LVM,iSCSI,FC,SAS Aaron Lauterer
2026-07-02 11:37   ` Maximiliano Sandoval
2026-07-02 11:46     ` Aaron Lauterer
2026-07-02 13:55 ` applied: [PATCH docs 1/2] pvesm: mention FC/SAS in the storage overview Thomas Lamprecht

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal