Tested this by setting up an LVM volume group on a shared LUN (via
iSCSI) according to the Proxmox multipath docs [0]. Replicated the steps
to reproduce given in Friedrich's comment in the bug ticket on a 2-node
cluster and was able to reproduce the original problems. With the
patches applied, the following scenario worked as I would expect it to:
- Created VM with ID 100 on shared LVM on node 1
- Restarted node 2
- Deleted VM 100
- Created VM 100 on node 2
Checked that:
- Device mapper device is not created on node 2 (output of `dmsetup ls |
grep 100` shows no results) during the reboot
- Creation of new VM 100 on node 2 is successful
Additionally also checked the migration scenario on the same 2-node cluster:
- Created VM with ID 100 on shared LVM on node 1
- Rebooted node 2
- Created backup of VM 100
- Destroyed VM 100
- Restored VM 100 from backup on node 1
- Started VM 100
- Live migrated VM 100 from node 1 to node 2
Checked that:
- Again, device mapper device is not created on reboot of node 2
- After restoring VM 100 on node 1 and starting it, the inactive LV
exists on node 2
- VM 100 is successfully live-migrated to node 2, the previously
inactive LV is set to active
Also ran the pve8to9 script:
- The script correctly detected that the LVM storage contained guest
volumes with autoactivation enabled
- After running `pve8to9 updatelvm`, lvs reported autoactivation
disabled for all volumes on the node
Consider this:
Tested-by: Michael Köppl <m.koeppl@proxmox.com>
Also had a look at the changes to the best of my abilities, taking the
previous discussions from v1 and v2 into account. Apart from one
suggestion I added to the pve-manager 3/3 patch, the changes look good
to me. So please also consider this:
Reviewed-by: Michael Köppl <m.koeppl@proxmox.com>
[0] https://pve.proxmox.com/wiki/Multipath
On 4/29/25 13:36, Friedrich Weber wrote:
> # Summary
>
> With default settings, LVM autoactivates LVs when it sees a new VG, e.g. after
> boot or iSCSI login. In a cluster with guest disks on a shared LVM VG (e.g. on
> top of iSCSI/Fibre Channel (FC)/direct-attached SAS), this can indirectly cause
> guest creation or migration to fail. See bug #4997 [1] and patch #2 for
> details.
>
> The primary goal of this series is to avoid autoactivating thick LVs that hold
> guest disks in order to fix #4997. For this, it patches the LVM storage plugin
> to create new LVs with autoactivation disabled, and implements a pve8to9 check
> and subcommand to disable autoactivation on existing LVs (see below for
> details).
>
> The series does the same for LVM-thin storages. While LVM-thin storages are
> inherently local and cannot run into #4997, it can still make sense to avoid
> unnecessarily activating thin LVs at boot.
>
> This series should only be applied for PVE 9, see below.
>
> Marked as RFC to get feedback on the general approach and some details, see
> patches #3 and #6. In any case, this series shouldn't be merged as-is, as it
> adds an incomplete stub implementation of pve8to9 (see below).
>
> # Mixed 7/8 cluster
>
> Unfortunately, we need to consider the mixed-version cluster between PVE 7 and
> PVE 8 because PVE 7/Bullseye's LVM does not know `--setautoactivation`. A user
> upgrading from PVE 7 will temporarily have a mixed 7/8 cluster. Once this
> series is applied, the PVE 8 nodes will create new LVs with
> `--setautoactivation n`, which the PVE 7 nodes do not know. In my tests, the
> PVE 7 nodes can read/interact with such LVs just fine, *but*: As soon as a PVE
> 7 node creates a new (unrelated) LV, the `--setautoactivation n` flag is reset
> to default `y` on *all* LVs of the VG. I presume this is because creating a new
> LV rewrites metadata, and the PVE 7 LVM doesn't write out the
> `--setautoactivation n` flag. I imagine (have not tested) this will cause
> problems on a mixed cluster.
>
> Hence, as also discussed in v2, we should only apply this series for PVE 9, as
> we can be sure all nodes are running at least PVE 8 then.
>
> # pve8to9 script
>
> As discussed in v2, this series implements
>
> (a) a pve8to9 check to detect thick and thin LVs with autoactivation enabled
> (b) a script to disable autoactivation on LVs when needed, intended to be run
> manually by the user during 8->9 upgrade
>
> pve8to9 doesn't exist yet, so patch #4 adds a stub implementation to have a
> basis for (a) and (b). We naturally don't have to go with this implementation,
> I'm happy to rebase once pve8to9 exists.
>
> Patch #5 moves the existing checks from `pve8to9` to `pve8to9 checklist`, to be
> able to implement (b) as a new subcommand. I realize this is a huge user-facing
> change, and we don't have to go with this approach. It is also incomplete, as
> patch #5 doesn't update the manpage. I included this to have a basis for the
> next patch.
>
> Patch #6 implements a pve8to9 subcommand for (b), but this can be moved to a
> dedicated script of course. Documentation for the new subcommand is missing.
>
> # Bonus fix for FC/SAS multipath+LVM issue
>
> As it turns out, this series seems to additionally fix an issue on hosts with
> LVM on FC/SAS-attached LUNs *with multipath* where LVM would report "Device
> mismatch detected" warnings because the LVs are activated too early in the boot
> process before multipath is available. Our current suggested workaround is to
> install multipath-tools-boot [2]. With this series applied and when users have
> upgraded to 9, this shouldn't be necessary anymore, as LVs are not
> auto-activated after boot.
>
> # Interaction with zfs-initramfs
>
> zfs-initramfs used to ship an an initramfs-tools script that unconditionally
> activates *all* VGs that are visible at boot time, ignoring the autoactivation
> flag. A fix was already applied in v2 [3].
>
> # Patch summary
>
> - Patch #1 is preparation
> - Patch #2 makes the LVM plugin create new LVs with `--setautoactivation n`
> - Patch #3 makes the LVM-thin plugin disable autoactivation for new LVs
> - Patch #4 creates a stub pve8to9 script (see pve8to9 section above)
> - Patch #5 moves pve8to9 checks to a subcommand (see pve8to9 section above)
> - Patch #6 adds a pve8to9 subcommand to disable autoactivation
> (see pve8ot9 section above)
>
> # Changes since v2
>
> - drop zfsonlinux patch that was since applied
> - add patches for LVM-thin
> - add pve8to9 patches
>
> v2: https://lore.proxmox.com/pve-devel/20250307095245.65698-1-f.weber@proxmox.com/
> v1: https://lore.proxmox.com/pve-devel/20240111150332.733635-1-f.weber@proxmox.com/
>
> [1] https://bugzilla.proxmox.com/show_bug.cgi?id=4997
> [2] https://pve.proxmox.com/mediawiki/index.php?title=Multipath&oldid=12039#%22Device_mismatch_detected%22_warnings
> [3] https://lore.proxmox.com/pve-devel/ad4c806c-234a-4949-885d-8bb369860cc0@proxmox.com/
>
> pve-storage:
>
> Friedrich Weber (3):
> lvm: create: use multiple lines for lvcreate command line
> fix #4997: lvm: create: disable autoactivation for new logical volumes
> lvmthin: disable autoactivation for new logical volumes
>
> src/PVE/Storage/LVMPlugin.pm | 10 +++++++++-
> src/PVE/Storage/LvmThinPlugin.pm | 18 +++++++++++++++++-
> 2 files changed, 26 insertions(+), 2 deletions(-)
>
>
> pve-manager stable-8:
>
> Friedrich Weber (3):
> cli: create pve8to9 script as a copy of pve7to8
> pve8to9: move checklist to dedicated subcommand
> pve8to9: detect and (if requested) disable LVM autoactivation
>
> PVE/CLI/Makefile | 1 +
> PVE/CLI/pve8to9.pm | 1695 ++++++++++++++++++++++++++++++++++++++++++++
> bin/Makefile | 12 +-
> bin/pve8to9 | 8 +
> 4 files changed, 1715 insertions(+), 1 deletion(-)
> create mode 100644 PVE/CLI/pve8to9.pm
> create mode 100755 bin/pve8to9
>
>
> Summary over all repositories:
> 6 files changed, 1741 insertions(+), 3 deletions(-)
>
_______________________________________________
pve-devel mailing list
pve-devel@lists.proxmox.com
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel
next prev parent reply other threads:[~2025-06-10 15:03 UTC|newest]
Thread overview: 16+ messages / expand[flat|nested] mbox.gz Atom feed top
2025-04-29 11:36 Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-storage v3 1/3] lvm: create: use multiple lines for lvcreate command line Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-storage v3 2/3] fix #4997: lvm: create: disable autoactivation for new logical volumes Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-storage v3 3/3] lvmthin: " Friedrich Weber
2025-06-10 15:00 ` Michael Köppl
2025-06-23 9:25 ` Friedrich Weber
2025-06-27 8:14 ` Fabian Grünbichler
2025-06-30 7:47 ` Friedrich Weber
2025-07-01 16:11 ` Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-manager stable-8 v3 1/3] cli: create pve8to9 script as a copy of pve7to8 Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-manager stable-8 v3 2/3] pve8to9: move checklist to dedicated subcommand Friedrich Weber
2025-04-29 11:36 ` [pve-devel] [PATCH pve-manager stable-8 v3 3/3] pve8to9: detect and (if requested) disable LVM autoactivation Friedrich Weber
2025-06-10 14:25 ` Michael Köppl
2025-06-23 9:25 ` Friedrich Weber
2025-06-10 15:03 ` Michael Köppl [this message]
2025-06-23 9:26 ` [pve-devel] [RFC storage/manager v3 0/6] fix #4997: lvm, lvm-thin: avoid autoactivating LVs Friedrich Weber
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=4319a564-8b07-4c5f-878d-188781f56592@proxmox.com \
--to=m.koeppl@proxmox.com \
--cc=f.weber@proxmox.com \
--cc=pve-devel@lists.proxmox.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal