From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from gate001.proxmox.com (gate001.proxmox.com [45.144.208.40]) by lore.proxmox.com (Postfix) with ESMTPS id 6104B1FF066 for ; Tue, 24 Nov 2026 13:21:26 +0100 (CET) Received: from gate001.proxmox.com (localhost.localdomain [127.0.0.1]) by gate001.proxmox.com (Proxmox) with ESMTP id 7E42121520; Tue, 24 Nov 2026 13:21:23 +0100 (CET) Message-ID: <9f279375-b419-4f20-894a-9d767b5e17dc@proxmox.com> Date: Tue, 24 Nov 2026 13:21:17 +0100 MIME-Version: 1.0 User-Agent: Mozilla Thunderbird Subject: Re: [PATCH installer v2] network: align VLAN interface names with the documentation To: pve-devel@lists.proxmox.com References: <20261124114245.2656326-1-s.ivanov@proxmox.com> Content-Language: en-US From: Stefan Hanreich In-Reply-To: <20261124114245.2656326-1-s.ivanov@proxmox.com> Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 7bit X-SPAM-LEVEL: Spam detection results: 0 AWL 0.188 Adjusted score from AWL reputation of From: address DMARC_MISSING 0.1 Missing DMARC policy KAM_DMARC_STATUS 0.01 Test Rule for DKIM or SPF Failure with Strict Alignment (newer systems) RCVD_IN_DNSWL_MED -2.3 Sender listed at https://www.dnswl.org/, medium trust SPF_HELO_NONE 0.001 SPF: HELO does not publish an SPF Record SPF_PASS -0.001 SPF: sender matches SPF record Message-ID-Hash: O6WXTHIK45VGYFC556BIZASFPXDUQLJ3 X-Message-ID-Hash: O6WXTHIK45VGYFC556BIZASFPXDUQLJ3 X-MailFrom: s.hanreich@proxmox.com X-Mailman-Rule-Misses: dmarc-mitigation; no-senders; approved; loop; banned-address; emergency; member-moderation; nonmember-moderation; administrivia; implicit-dest; max-recipients; max-size; news-moderation; no-subject; digests; suspicious-header X-Mailman-Version: 3.3.10 Precedence: list List-Id: Proxmox VE development discussion List-Help: List-Owner: List-Post: List-Subscribe: List-Unsubscribe: gave this a quick spin on a rebuilt ISO, generated vmbr0.137 as expected. Tested-by: Stefan Hanreich On 11/24/26 12:43 PM, Stoiko Ivanov wrote: > Our documentation has relied on ifupdown(2)'s way of handling > $iface.$vid as identifier for VLAN interfaces for a long while > (looking through pve-docs commit history shows `vlan-raw-device` > only occurring in the api-viewer) > > One case where the $iface.$vlan_id naming breaks is for long > interface names (e.g. enp129s0f1np1, or mac-based enxdadadadadada) > > Use the dot-notation where this is possible, and fallback > to `vlan$vlan_id` with `vlan-raw-device $iface` where this is needed > > For the dot-notation case also drop `vlan-raw-device` to avoid > misconfigurations due to mismatches/incomplete substitutions. > > I considered also adding `vlan-id $vlan_id` to the config in the > `vlan-raw-device` case, based on ifupdown-addons-interfaces(5) saying > it requires it, but my tests show it's not needed. > > I considered encoding the interface name as "utf-8" for the length > comparison, but we luckily restrict the pinned names to ascii only. > > Sticking to our documentation should help reducing the different > ways that people are configuring their interfaces and thus hopefully > the potential for errors. > > Signed-off-by: Stoiko Ivanov > --- > v1->v2: > * merge both patches into a single one > * handle the quite real case of long predictable ifnames (enp129s0f1np1) > pointed out by Stefan (and a review tool) > * add a test-case. > v1: > https://lore.proxmox.com/pve-devel/dbbc7520-5e8a-4e10-9371-d1c7745cfd5c@proxmox.com/T/#t > > Proxmox/Install.pm | 12 +++- > test/generate-ifupdown2-config.pl | 106 +++++++++++++++++++++--------- > 2 files changed, 85 insertions(+), 33 deletions(-) > > diff --git a/Proxmox/Install.pm b/Proxmox/Install.pm > index 76bfd04..c1660fb 100644 > --- a/Proxmox/Install.pm > +++ b/Proxmox/Install.pm > @@ -16,6 +16,7 @@ use Proxmox::Install::StorageConfig; > use Proxmox::Sys::Block qw(get_cached_disks wipe_disk partition_bootable_disk); > use Proxmox::Sys::Command qw(run_command syscmd); > use Proxmox::Sys::File qw(file_read_firstline file_read_all file_write_all); > +use Proxmox::Sys::Net; > use Proxmox::Sys::ZFS; > use Proxmox::UI; > > @@ -887,9 +888,16 @@ sub generate_ifupdown2_config { > my $get_vlan_stanza = sub { > my ($raw_device) = @_; > > - my $config = "auto vlan$vlan_id\niface vlan$vlan_id $ntype static\n\taddress $cidr\n"; > + my $devname = "$raw_device.$vlan_id"; > + my $long_if = length($devname) > Proxmox::Sys::Net::MAX_IFNAME_LEN; > + $devname = "vlan$vlan_id" if $long_if; > + > + my $config = "auto $devname\niface $devname $ntype static\n\taddress $cidr\n"; > $config .= "\tgateway $gateway\n" if !$is_gateway6_from_ra; > - return [4, "vlan$vlan_id", $config . "\tvlan-raw-device $raw_device\n"]; > + > + $config .= "\tvlan-raw-device $raw_device\n" if $long_if; > + > + return [4, $devname, $config]; > }; > > if ($iso_env->{cfg}->{bridged_network} && defined($vlan_id)) { > diff --git a/test/generate-ifupdown2-config.pl b/test/generate-ifupdown2-config.pl > index a3b7bdb..9bf6a40 100755 > --- a/test/generate-ifupdown2-config.pl > +++ b/test/generate-ifupdown2-config.pl > @@ -152,11 +152,10 @@ is_generated( > auto eno1 > iface eno1 inet manual > > -auto vlan5 > -iface vlan5 inet static > +auto eno1.5 > +iface eno1.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device eno1 > > iface eno2 inet manual > EOT > @@ -194,11 +193,10 @@ iface bond0 inet manual > bond-miimon 100 > bond-mode active-backup > > -auto vlan5 > -iface vlan5 inet static > +auto bond0.5 > +iface bond0.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device bond0 > > auto eno1 > iface eno1 inet manual > @@ -244,11 +242,10 @@ iface vmbr0 inet manual > bridge-vlan-aware yes > bridge-vids 2-4094 > > -auto vlan5 > -iface vlan5 inet static > +auto vmbr0.5 > +iface vmbr0.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device vmbr0 > EOT > , 'host network setup', > ); > @@ -304,11 +301,10 @@ iface vmbr0 inet manual > bridge-vlan-aware yes > bridge-vids 2-4094 > > -auto vlan5 > -iface vlan5 inet static > +auto vmbr0.5 > +iface vmbr0.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device vmbr0 > EOT > , 'host network setup', > ); > @@ -323,11 +319,10 @@ iface eno1 inet manual > > iface eno2 inet manual > > -auto vlan5 > -iface vlan5 inet static > +auto eno1.5 > +iface eno1.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device eno1 > EOT > , 'interfaces ordered like the network API', > ); > @@ -347,11 +342,10 @@ iface bond0 inet manual > bond-miimon 100 > bond-mode active-backup > > -auto vlan5 > -iface vlan5 inet static > +auto bond0.5 > +iface bond0.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device bond0 > EOT > , 'interfaces ordered like the network API', > ); > @@ -363,11 +357,10 @@ is_generated( > auto eno1 > iface eno1 inet manual > > -auto vlan5 > -iface vlan5 inet static > +auto eno1.5 > +iface eno1.5 inet static > address 192.168.0.10/24 > gateway 192.168.0.1 > - vlan-raw-device eno1 > > iface eno2 inet manual > EOT > @@ -749,11 +742,10 @@ iface bond0 inet6 manual > bond-miimon 100 > bond-mode active-backup > > -auto vlan5 > -iface vlan5 inet6 static > +auto bond0.5 > +iface bond0.5 inet6 static > address 2001:db8::1/64 > gateway fe80::1 > - vlan-raw-device bond0 > > auto eno1 > iface eno1 inet6 manual > @@ -797,10 +789,9 @@ is_generated( > auto eno1 > iface eno1 inet6 manual > > -auto vlan5 > -iface vlan5 inet6 static > +auto eno1.5 > +iface eno1.5 inet6 static > address 2001:db8::1/64 > - vlan-raw-device eno1 > > iface eno2 inet6 manual > EOT > @@ -822,10 +813,9 @@ iface vmbr0 inet6 manual > bridge-vlan-aware yes > bridge-vids 2-4094 > > -auto vlan5 > -iface vlan5 inet6 static > +auto vmbr0.5 > +iface vmbr0.5 inet6 static > address 2001:db8::1/64 > - vlan-raw-device vmbr0 > EOT > , 'gateway learned from router advertisements on the management VLAN on a bridge is not configured', > ); > @@ -834,7 +824,7 @@ set_config(bridge => 0, bond => 0, vlan => 1); > Proxmox::Install::Config::merge({ mngmt_vlan => { enabled => 1, vid => 200 } }); > like( > Proxmox::Install::generate_ifupdown2_config(), > - qr/^iface vlan200 inet6 static\n\taddress 2001:db8::1\/64\n\tgateway fe80::1\n/m, > + qr/^iface eno1.200 inet6 static\n\taddress 2001:db8::1\/64\n\tgateway fe80::1\n/m, > 'management VLAN other than the installation environment one gets the configured gateway', > ); > > @@ -845,6 +835,60 @@ like( > 'untagged management network with a tagged installation environment gets the configured gateway', > ); > > +# handling of long predictable nic name > +$proxmox_install_runenv->redefine( > + get => sub { > + return { > + network => { > + interfaces => { > + enp129s0f1np1 => { > + mac => '12:34:56:ab:cd:ef', > + index => 1, > + name => 'enp129s0f1np1', > + pinned_id => '0', > + }, > + }, > + }, > + }; > + }, > +); > +set_config(bridge => 0, bond => 0, vlan => 0); > +Proxmox::Install::Config::merge({ > + mngmt_nic => 'enp129s0f1np1', > + cidr => '192.168.0.10/24', > + gateway => '192.168.0.1', > +}); > +is_generated( > + < +auto enp129s0f1np1 > +iface enp129s0f1np1 inet static > + address 192.168.0.10/24 > + gateway 192.168.0.1 > +EOT > + , 'direct config on a physical link with a long name', > +); > + > +set_config(bridge => 0, bond => 0, vlan => 1); > +Proxmox::Install::Config::merge({ > + mngmt_nic => 'enp129s0f1np1', > + cidr => '192.168.0.10/24', > + gateway => '192.168.0.1', > + mngmt_vlan => { enabled => 1, vid => 4094 }, > +}); > +is_generated( > + < +auto enp129s0f1np1 > +iface enp129s0f1np1 inet manual > + > +auto vlan4094 > +iface vlan4094 inet static > + address 192.168.0.10/24 > + gateway 192.168.0.1 > + vlan-raw-device enp129s0f1np1 > +EOT > + , 'VLAN on a physical link with a long name', > +); > + > for my $id (0, 1, 4095, 'abc', '1.5') { > eval { Proxmox::Install::Config::set_mngmt_vlan_opt('vid', $id) }; > like(