From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: <pve-devel-bounces@lists.proxmox.com> Received: from firstgate.proxmox.com (firstgate.proxmox.com [IPv6:2a01:7e0:0:424::9]) by lore.proxmox.com (Postfix) with ESMTPS id 698521FF168 for <inbox@lore.proxmox.com>; Tue, 4 Mar 2025 16:41:53 +0100 (CET) Received: from firstgate.proxmox.com (localhost [127.0.0.1]) by firstgate.proxmox.com (Proxmox) with ESMTP id C90EE497A; Tue, 4 Mar 2025 16:41:49 +0100 (CET) From: Alexander Zeidler <a.zeidler@proxmox.com> To: pve-devel@lists.proxmox.com Date: Tue, 4 Mar 2025 16:40:55 +0100 Message-Id: <20250304154101.3-2-a.zeidler@proxmox.com> X-Mailer: git-send-email 2.39.5 In-Reply-To: <20250304154101.3-1-a.zeidler@proxmox.com> References: <20250304154101.3-1-a.zeidler@proxmox.com> MIME-Version: 1.0 X-SPAM-LEVEL: Spam detection results: 0 AWL 0.087 Adjusted score from AWL reputation of From: address BAYES_00 -1.9 Bayes spam probability is 0 to 1% DMARC_MISSING 0.1 Missing DMARC policy KAM_DMARC_STATUS 0.01 Test Rule for DKIM or SPF Failure with Strict Alignment SPF_HELO_NONE 0.001 SPF: HELO does not publish an SPF Record SPF_PASS -0.001 SPF: sender matches SPF record Subject: [pve-devel] [PATCH docs 1/7] system-requirements: revise subchapter and provide more details X-BeenThere: pve-devel@lists.proxmox.com X-Mailman-Version: 2.1.29 Precedence: list List-Id: Proxmox VE development discussion <pve-devel.lists.proxmox.com> List-Unsubscribe: <https://lists.proxmox.com/cgi-bin/mailman/options/pve-devel>, <mailto:pve-devel-request@lists.proxmox.com?subject=unsubscribe> List-Archive: <http://lists.proxmox.com/pipermail/pve-devel/> List-Post: <mailto:pve-devel@lists.proxmox.com> List-Help: <mailto:pve-devel-request@lists.proxmox.com?subject=help> List-Subscribe: <https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel>, <mailto:pve-devel-request@lists.proxmox.com?subject=subscribe> Reply-To: Proxmox VE development discussion <pve-devel@lists.proxmox.com> Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Errors-To: pve-devel-bounces@lists.proxmox.com Sender: "pve-devel" <pve-devel-bounces@lists.proxmox.com> Signed-off-by: Alexander Zeidler <a.zeidler@proxmox.com> --- pve-system-requirements.adoc | 29 ++++++++++++++++++++--------- 1 file changed, 20 insertions(+), 9 deletions(-) diff --git a/pve-system-requirements.adoc b/pve-system-requirements.adoc index 8a982a8..82d9be5 100644 --- a/pve-system-requirements.adoc +++ b/pve-system-requirements.adoc @@ -1,3 +1,4 @@ +[[system_requirements]] System Requirements ------------------- ifdef::wiki[] @@ -6,7 +7,8 @@ endif::wiki[] We recommend using high quality server hardware, when running {pve} in production. To further decrease the impact of a failed host, you can run {pve} in -a cluster with highly available (HA) virtual machines and containers. +a cluster with xref:chapter_ha_manager[highly available (HA)] virtual +machines and containers. {pve} can use local storage (DAS), SAN, NAS, and distributed storage like Ceph RBD. For details see xref:chapter_storage[chapter storage]. @@ -26,7 +28,9 @@ used in production. * Hard drive -* One network card (NIC) +* One network card (NIC), used for fetching system updates and access +via xref:chapter_gui[web interface], `ssh` or +link:api-viewer/index.html[{pve} API] [[install_recommended_requirements]] @@ -39,15 +43,22 @@ Recommended System Requirements guests. For Ceph and ZFS, additional memory is required; approximately 1GB of memory for every TB of used storage. -* Fast and redundant storage, best results are achieved with SSDs. +* Fast and redundant storage, best results are achieved with SSDs. Do + not use SD cards or USB flash drives, as these have a lower + durability and performance. -* OS storage: Use a hardware RAID with battery protected write cache (``BBU'') - or non-RAID with ZFS (optional SSD for ZIL). +* OS storage: +** An HBA with a redundant xref:chapter_zfs[ZFS] RAID level. If not + using fast enterprise SSDs with power-loss protection, optionally + add one for use as xref:sysadmin_zfs_add_cache_and_log_dev[SLOG]. +** Or a hardware RAID controller with battery-backed write cache (BBU) + and not ZFS, as the combination can lead to data loss. * VM storage: -** For local storage, use either a hardware RAID with battery backed write cache - (BBU) or non-RAID for ZFS and Ceph. Neither ZFS nor Ceph are compatible with a - hardware RAID controller. +** For local storage, the same recommendations apply as for OS + storage. However, if a hardware RAID controller is used, in + addition to ZFS, xref:chapter_pveceph[Ceph] is also incompatible + with it. ** Shared and distributed storage is possible. ** SSDs with Power-Loss-Protection (PLP) are recommended for good performance. Using consumer SSDs is discouraged. @@ -75,7 +86,7 @@ browsers: * Firefox, a release from the current year, or the latest Extended Support Release * Chrome, a release from the current year -* Microsoft's currently supported version of Edge +* Edge, Microsoft's currently supported release * Safari, a release from the current year When accessed from a mobile device, {pve} will show a lightweight, touch-based -- 2.39.5 _______________________________________________ pve-devel mailing list pve-devel@lists.proxmox.com https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel