all lists on lists.proxmox.com
 help / color / mirror / Atom feed
 messages from 2026-11-19 15:33:58 to 2026-11-20 03:13:49 UTC [more...]

[PATCH cluster/guest-common/qemu-server/container/manager/docs v5 00/41] fix #7846: guest identity (uid) and cluster ID
 2026-11-20  3:07 UTC  (43+ messages)
` [PATCH cluster v5 01/41] pmxcfs: reject changes to the cluster ID file from user space
` [PATCH cluster v5 02/41] pmxcfs: generate a cluster ID on standalone nodes
` [PATCH cluster v5 03/41] pmxcfs: dfsm: add a callback that runs once all members are in sync
` [PATCH cluster v5 04/41] pmxcfs: quorum: record the corosync membership
` [PATCH cluster v5 05/41] pmxcfs: dcdb: generate the cluster ID once the cluster is in sync
` [PATCH cluster v5 06/41] cluster: add helper to read the cluster ID
` [PATCH cluster v5 07/41] pmxcfs: allow removing the cluster ID file in forced local mode
` [PATCH guest-common v5 08/41] guest identity: add helpers for the guest uid and registration time
` [PATCH guest-common v5 09/41] abstract config: assign a guest identity and keep it on config writes
` [PATCH guest-common v5 10/41] abstract config: let the VMID reservation return the previous state
` [PATCH guest-common v5 11/41] guest identity: allow adopting a uid that is unused in the cluster
` [PATCH guest-common v5 12/41] migrate: add shared helpers for the identity command of the migration tunnel
` [PATCH guest-common v5 13/41] vzdump: notes template: list the uid variable
` [PATCH qemu-server v5 14/41] api: restore: release the VMID if a restore to an unused VMID fails
` [PATCH qemu-server v5 15/41] api: migrate, clone: refuse targets that would drop the guest identity
` [PATCH qemu-server v5 16/41] fix #7846: config: add a guest identity to the 'meta' property
` [PATCH qemu-server v5 17/41] restore: adopt the guest uid from the backup where possible
` [PATCH qemu-server v5 18/41] api: remote migration: adopt the guest uid from the source
` [PATCH qemu-server v5 19/41] api: status: return the guest uid
` [PATCH container v5 20/41] restore: decide by the reservation whether the container is new
` [PATCH container v5 21/41] config: add read-only meta property with the creation time
` [PATCH container v5 22/41] fix #7846: config: add a guest identity to the 'meta' property
` [PATCH container v5 23/41] api: migrate, clone: refuse targets that would drop the guest identity
` [PATCH container v5 24/41] restore: adopt the guest uid from the backup where possible
` [PATCH container v5 25/41] restore: refuse overwriting a container with another guest's backup
` [PATCH container v5 26/41] api: remote migration: adopt the guest uid from the source
` [PATCH container v5 27/41] api: status: return the guest uid
` [PATCH manager v5 28/41] api: cluster resources: add guest uid and registration time
` [PATCH manager v5 29/41] api: cluster status: add cluster ID
` [PATCH manager v5 30/41] ui: datacenter summary: show the "
` [PATCH manager v5 31/41] ui: restore: allow overwriting a guest with a backup of another guest
` [PATCH manager v5 32/41] ui: migrate: refuse target nodes that would drop the guest identity
` [PATCH manager v5 33/41] ui: guest summary: show "
` [PATCH manager v5 34/41] api: bulk migrate: refuse targets that would drop "
` [PATCH manager v5 35/41] vzdump: notes template: add the guest uid as variable
` [PATCH docs v5 36/41] vzdump: restore: describe what a failed restore can leave behind
` [PATCH docs v5 37/41] vzdump: describe the guest identity of VMs and containers
` [PATCH docs v5 38/41] pvecm: document the cluster ID and how to get a new one
` [PATCH docs v5 39/41] qm: configuration: describe the read-only meta property
` [PATCH docs v5 40/41] pct: "
` [PATCH docs v5 41/41] vzdump: notes: document the uid template variable

[PATCH] lrm: refuse targets dropping the guest identity before stopping guests
 2026-11-20  2:54 UTC 

[PATCH pve-manager] ui: sdn: ipam: keep the subnets of different zones apart
 2026-11-19 23:16 UTC  (2+ messages)
` applied: "

[PATCH-SERIES docs/ha-manager/manager v5 00/10] fix #6144: add api and ui for node maintenance mode
 2026-11-19 22:28 UTC  (2+ messages)
` applied: "

[PATCH pve-manager v3 0/3] ui: prompt users for reload when web ui version changes
 2026-11-19 22:21 UTC  (5+ messages)
` [PATCH pve-manager v3 1/3] api: factor out read_pwt_version and pwt_base_dir
` [PATCH pve-manager v3 2/3] api: provide GUI versions via index and /cluster/resources
` [PATCH pve-manager v3 3/3] ui: workspace: prompt user for reload when UI packages were updated

[PATCH common v2] Added D state checking to `run` subroutine
 2026-11-19 22:00 UTC  (2+ messages)

[PATCH common/manager/network/proxmox{-ve-rs,-perl-rs,-widget-toolkit} v3 00/32] SDN VRF support
 2026-11-19 20:10 UTC  (7+ messages)
` [PATCH pve-network v3 14/32] sdn: evpn: add unreachable IPv6 default route to zone VRFs

[PATCH v7 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM
 2026-11-19 19:49 UTC  (2+ messages)
` superseded: "

[PATCH cluster/guest-common/qemu-server/container/manager/docs v4 00/41] fix #7846: guest identity (uid) and cluster ID
 2026-11-19 19:49 UTC  (2+ messages)
` superseded: "

[PATCH v8 cluster,storage,docs,manager 00/43] SAN: cluster-wide multipath, SAN views and a guided setup for shared LVM
 2026-11-19 19:46 UTC  (44+ messages)
` [PATCH v8 cluster 01/43] cfs: observe the multipath configuration files
` [PATCH v8 storage 02/43] diskmanage: collect disk transport type from lsblk
` [PATCH v8 storage 03/43] diskmanage: qualify NVMe over Fabrics transport
` [PATCH v8 storage 04/43] diskmanage: optionally include iSCSI session devices in disk enumeration
` [PATCH v8 storage 05/43] diskmanage: collect native NVMe multipath path state
` [PATCH v8 storage 06/43] iscsi: factor out session device map from device list
` [PATCH v8 storage 07/43] multipath: add a library around multipathd
` [PATCH v8 storage 08/43] diskmanage: add helper to list multipath devices
` [PATCH v8 storage 09/43] multipath: add a cluster-wide configuration
` [PATCH v8 storage 10/43] iscsi: add an option to manage storage LUNs with multipath
` [PATCH v8 storage 11/43] lvm: activate a missing base volume before using the volume group
` [PATCH v8 storage 12/43] multipath: apply the configuration on every node
` [PATCH v8 storage 13/43] multipath: publish per-node status
` [PATCH v8 storage 14/43] api: add endpoints for the cluster-wide multipath configuration
` [PATCH v8 storage 15/43] api: multipath: add the cluster-wide health status
` [PATCH v8 storage 16/43] diskmanage: look up the requested disks by name
` [PATCH v8 storage 17/43] diskmanage: read the udev data of all disks with one call
` [PATCH v8 storage 18/43] api: scan: add a SAN LUN inventory
` [PATCH v8 storage 19/43] pvesm: expose the "
` [PATCH v8 storage 20/43] api: add node-level iSCSI status
` [PATCH v8 storage 21/43] api: scan: name the portal of an iSCSI path
` [PATCH v8 storage 22/43] disks: lvm: drop unused imports
` [PATCH v8 storage 23/43] disks: lvm: allow volume groups on SAN LUNs and multipath maps
` [PATCH v8 storage 24/43] disks: lvm: refuse to destroy the volume group of a shared storage
` [PATCH v8 storage 25/43] disks: allow wiping a SAN LUN that no storage uses
` [PATCH v8 storage 26/43] api: scan: report the process that has a SAN LUN open
` [PATCH v8 docs 27/43] storage: document the cluster-wide multipath management
` [PATCH v8 docs 28/43] storage: multipath: describe the use shown for an open LUN
` [PATCH v8 manager 29/43] pvestatd: apply the multipath configuration and report the node status
` [PATCH v8 manager 30/43] report: add the managed multipath configuration
` [PATCH v8 manager 31/43] api: cluster: add the multipath endpoints
` [PATCH v8 manager 32/43] api: nodes: expose the iSCSI status
` [PATCH v8 manager 33/43] ui: dc: add a SAN view
` [PATCH v8 manager 34/43] ui: storage: iscsi: add the multipath option
` [PATCH v8 manager 35/43] ui: lvm: enable shared when a base storage is selected
` [PATCH v8 manager 36/43] ui: node: add SAN LUNs panel
` [PATCH v8 manager 37/43] ui: node: san: wipe a LUN that no storage uses
` [PATCH v8 manager 38/43] ui: node: san: show iSCSI targets and sessions
` [PATCH v8 manager 39/43] ui: dc: san: add a guided setup for shared LVM on iSCSI
` [PATCH v8 manager 40/43] ui: dc: san: add a guided setup for shared LVM on Fibre Channel
` [PATCH v8 manager 41/43] ui: storage: point the iSCSI and LVM add dialogs to the SAN view
` [PATCH v8 manager 42/43] ui: san: show the guest or process that has a LUN open
` [PATCH v8 manager 43/43] ui: node: san: add a column for the target or subsystem of a LUN

[PATCH docs/manager/network/proxmox{,-ve-rs,-firewall} 00/14] sdn: conntrack zones and SNAT for simple zones with a dedicated VRF
 2026-11-19 19:45 UTC  (15+ messages)
` [PATCH proxmox 01/14] network-api: expose the master device of a link
` [PATCH proxmox-ve-rs 02/14] sdn: config: read the conntrack zone of zones with a dedicated VRF
` [PATCH proxmox-ve-rs 03/14] sdn: conntrack: map the interfaces of zone VRFs to their conntrack zone
` [PATCH pve-network 04/14] sdn: simple: SNAT via the uplinks of zone VRFs
` [PATCH pve-network 05/14] sdn: zones: assign a conntrack zone to zones with a dedicated VRF
` [PATCH proxmox-firewall 06/14] firewall: apply vnet rules to host traffic from vnets in a VRF
` [PATCH proxmox-firewall 07/14] nftables: expression: add a constructor for map lookups
` [PATCH proxmox-firewall 08/14] nftables: statement: add a helper for setting the conntrack zone
` [PATCH proxmox-firewall 09/14] nftables: expression: convert the conntrack zones of zone VRFs
` [PATCH proxmox-firewall 10/14] firewall: add a command applying "
` [PATCH proxmox-firewall 11/14] firewall: put guest traffic of zone VRFs into their conntrack zone
` [PATCH pve-manager 12/14] network: apply the conntrack zones of zone VRFs
` [PATCH pve-manager 13/14] network: warn if pve-firewall cannot isolate guests in "
` [PATCH pve-docs 14/14] pvesdn: simple zones: document dedicated VRFs

[PATCH common/manager/network/proxmox{-ve-rs,-perl-rs,-widget-toolkit} v3 00/28] SDN VRF support
 2026-11-19 19:41 UTC  (29+ messages)
` [PATCH pve-common v3 01/28] interfaces: preserve VRF membership across address family changes
` [PATCH proxmox-ve-rs v3 02/28] frr: add VRF-aware OSPF rendering
` [PATCH proxmox-ve-rs v3 03/28] sdn: add zone references to OSPF and BGP fabrics
` [PATCH proxmox-ve-rs v3 04/28] sdn: generate fabric routing configuration in zone VRFs
` [PATCH proxmox-ve-rs v3 05/28] sdn: fix VRF route-map scoping and zone ID validation
` [PATCH proxmox-ve-rs v3 06/28] tests: fabrics: add tests for fabrics in VRFs
` [PATCH proxmox-ve-rs v3 07/28] sdn: allow static routes in simple zone VRFs
` [PATCH proxmox-perl-rs v3 08/28] pve-rs: fabrics: assign network interfaces to configured VRFs
` [PATCH proxmox-perl-rs v3 09/28] pve-rs: fabrics: make per-fabric status queries VRF-aware
` [PATCH proxmox-perl-rs v3 10/28] pve-rs: fabrics: include VRF routes in aggregate status
` [PATCH proxmox-perl-rs v3 11/28] pve-rs: fabrics: expose host interface membership
` [PATCH proxmox-perl-rs v3 12/28] sdn: expose static routes for simple zone uplinks
` [PATCH pve-network v3 13/28] sdn: evpn: add unreachable IPv6 default route to zone VRFs
` [PATCH pve-network v3 14/28] sdn: add optional VRFs for simple zones
` [PATCH pve-network v3 15/28] sdn: allow fabrics to use simple zone VRFs
` [PATCH pve-network v3 16/28] sdn: require underlay fabrics to use the default VRF
` [PATCH pve-network v3 17/28] sdn: move full range CIDR formats into a separate module
` [PATCH pve-network v3 18/28] sdn: simple: support static routes in zone routing tables
` [PATCH pve-network v3 19/28] sdn: dhcp: only configure DHCP for zones on the local node
` [PATCH pve-network v3 20/28] sdn: dhcp: run dnsmasq in the zone VRF
` [PATCH pve-network v3 21/28] sdn: dhcp: fix DNS server option for IPv4 subnets without gateway
` [PATCH pve-network v3 22/28] sdn: evpn: no exit node null routes for simple zone VRFs
` [PATCH proxmox-widget-toolkit v3 23/28] ui: network: allow selecting a VRF for host interfaces
` [PATCH pve-manager v3 24/28] ui: sdn: add VRF zone selection for fabrics
` [PATCH pve-manager v3 25/28] network: allow setting the VRF of host interfaces
` [PATCH pve-manager v3 26/28] ui: sdn: allow static routes for Simple zone VRFs
` [PATCH pve-manager v3 27/28] network: generate SDN DHCP config after ifreload
` [PATCH pve-manager v3 28/28] ui: sdn: subnet: allow setting the DHCP DNS server

[PATCH common 0/2] Adding D state checking to the run command
 2026-11-19 18:49 UTC  (6+ messages)
` [PATCH common 1/2] Added subroutine to check process status
` [PATCH common 2/2] Added logic to check for d state to run subroutine
` superseded [PATCH common 0/2] Adding D state checking to the run command

[PATCH pve-manager v2 0/3] ui: prompt users for reload when web ui version changes
 2026-11-19 17:13 UTC  (5+ messages)
` [PATCH pve-manager v2 1/3] api: factor out read_pwt_version and pwt_base_dir
` [PATCH pve-manager v2 2/3] api: provide GUI versions via index and /cluster/resources
` [PATCH pve-manager v2 3/3] ui: workspace: prompt user for reload when UI packages were updated
` superseded: [PATCH pve-manager v2 0/3] ui: prompt users for reload when web ui version changes

[RFC proxmox-perl-rs/qemu-server/qemu-server-rs v4 0/4] vCPU binding for qemu guests
 2026-11-19 17:08 UTC  (7+ messages)
` [PATCH qemu-server v4 4/4] cpu: add cpu binding

[PATCH manager 0/3] ui: prompt users for reload when web ui version changes
 2026-11-19 15:40 UTC  (2+ messages)
` superseded: "


This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal