messages from 2026-08-20 14:52:27 to 2026-08-25 11:10:26 UTC [more...]
SPAM: [RFC pve-http-server/qemu-server/pve-manager/pve-{qemu-kyber,kyberproxy, kyber-web,qemu-rdp,rdpproxy,rdp-web} 00/13] add rdp && kyber consoles for qemu over D-Bus display
2026-08-25 11:08 UTC (9+ messages)
` SPAM: [RFC pve-http-server 01/13] anyevent : proxy a path prefix to a local http proxy
` SPAM: [RFC qemu-server 02/13] add D-Bus display support
` SPAM: [RFC qemu-server 03/13] add kyber display
` SPAM: [RFC qemu-server 04/13] add rdp display
` SPAM: [RFC qemu-server 05/13] add experimental kyber-gl display
` SPAM: [RFC pve-manager 06/13] ui: add kyber console
` SPAM: [RFC pve-manager 07/13] ui: add rdp console
` SPAM: [RFC pve-kyber-web 10/13] add pve-kyber-web: console's webassembly client
[PATCH manager 0/4] fix #7801: ui: warn about problematic virtio versions on iso select
2026-08-25 11:02 UTC (5+ messages)
` [PATCH pve-manager 1/4] ui: iso selector: add option to warn about virtio versions with issues
` [PATCH pve-manager 2/4] ui: cd edit: add `warnVirtio` option to pass to iso selector
` [PATCH pve-manager 3/4] partially fix #7801: ui: ospanel: warn about problematic virtio versions
` [PATCH pve-manager 4/4] partially fix #7801: ui: hardware view: "
[PATCH pve-apiclient 1/1] client: allow passing query parameters to delete calls
2026-08-25 9:45 UTC (4+ messages)
[PATCH pve-apiclient] pass parameters for DELETE requests as query string
2026-08-25 9:42 UTC (2+ messages)
` applied: "
[PATCH many 0/8] fix #7530: Implement download bandwidth and restore limits for pbs-restore
2026-08-25 9:17 UTC (9+ messages)
` [PATCH proxmox 1/8] pbs-api-types: expose ClientRateLimitConfig fields as pub
` [PATCH proxmox-backup-qemu 2/8] restore: fix useless borrow clippy warnings for archive names
` [PATCH proxmox-backup-qemu 3/8] commands: fix clippy error for reimplementing Result::ok()
` [PATCH proxmox-backup-qemu 4/8] submodules: bump proxmox-backup submodule to 4.2.5 and fix api changes
` [PATCH proxmox-backup-qemu 5/8] restore: implement `bw-limit` parameter imposing download rate limits
` [PATCH proxmox-backup-qemu 6/8] restore: implement `rate-limit` imposing chunk data stream limits
` [PATCH pve-qemu 7/8] fix #7530: pbs-restore: expose optional rate limit parameters
` [PATCH qemu-server 8/8] pbs-restore: set restore bandwidth limit for volumes
[PATCH pve-kernel] build: ship Rust artifacts for external modules
2026-08-24 17:52 UTC (2+ messages)
[PATCH pve-docs 0/2] qm: pci passthrough: the AtomicOps caveat of the all-functions form
2026-08-24 17:08 UTC (3+ messages)
` [PATCH pve-docs 1/2] qm: pci passthrough: note the AtomicOps caveat of "
` [PATCH pve-docs 2/2] qm: pci passthrough: name the function in the GPU example
[PATCH 0/2] android: register OpenID Connect callback activity for #4281
2026-08-21 8:00 UTC (22+ messages)
` [PATCH v2 0/7] app: implement OpenID Connect (OAuth) realm login (#4281)
` [PATCH dart-api-client v2 1/2] fix #4281: access: add `type` property to `PveAccessDomainModel`
` [PATCH dart-api-client v2 2/2] fix #4281: access: add OpenID Connect auth-url/login helpers
` [PATCH v3 00/10] app: implement OpenID Connect (OAuth) realm login (#4281)
` [PATCH dart-api-client v3 1/2] fix #4281: access: add `type` property to `PveAccessDomainModel`
` [PATCH dart-api-client v3 2/2] fix #4281: access: add OpenID Connect auth-url/login helpers
` [PATCH login-manager v3 1/5] fix #4281: deps: add flutter_web_auth_2 dependency
` [PATCH login-manager v3 2/5] refactor: ui: factor out shared login tail into _finishLogin
` [PATCH login-manager v3 3/5] refactor: ui: split password form into its own widget
` [PATCH login-manager v3 4/5] fix #4281: ui: add OpenID Connect login flow to login form
` [PATCH login-manager v3 5/5] fix #4281: ui: fix stale Continue button state on realm switch
` [PATCH flutter-frontend v3 1/3] chore: regenerate plugin registrant for flutter_web_auth_2
` [PATCH flutter-frontend v3 2/3] fix #4281: android: set taskAffinity="" on MainActivity
` [PATCH flutter-frontend v3 3/3] fix #4281: android: register OpenID Connect callback activity
[PATCH datacenter-manager v2] add `make coverage` build target
2026-08-25 6:45 UTC
[PATCH datacenter-manager] add `make coverage` build target
2026-08-25 6:40 UTC (2+ messages)
[PATCH proxmox-backup 1/1] faq: add warning about using apt upgrade
2026-08-25 6:29 UTC (2+ messages)
[PATCH container] api: template: allow creating template from ct with disk on LVM
2026-08-24 15:33 UTC (2+ messages)
[PATCH qemu-server v2 0/3] memory: add verbose_description to NUMA policy
2026-08-24 15:22 UTC (4+ messages)
` [PATCH qemu-server v2 2/3] memory: add default NUMA allocation policy
` partially-applied: [PATCH qemu-server v2 0/3] memory: add verbose_description to NUMA policy
[PATCH qemu-server v4] fix #7711: pci: try to detect large memory region preconditions
2026-08-24 14:40 UTC (3+ messages)
[PATCH docs/guest-common/qemu-server v3 0/4] add new pci passthrough specific hookscript phase
2026-08-24 14:38 UTC (9+ messages)
` [PATCH guest-common v3 1/1] helpers: exec hookscript: add optional parameters
` [PATCH qemu-server v3 1/2] pci: factor 'prepare_pci_devices' out to PVE::QemuServer::PCI module
` [PATCH qemu-server v3 2/2] pci: call hookscript for each prepared pci device
` [PATCH docs v3 1/1] examples: add new hookscript phase to example hookscript
[PATCH datacenter-manager/proxmox v2 00/20] inject application context via API macro for easier integration testing
2026-08-24 13:57 UTC (37+ messages)
` [PATCH proxmox v2 01/20] router: introduce shared state
` [PATCH proxmox v2 02/20] rest-server: allow to inject "
` [PATCH proxmox v2 03/20] api-macro: support shared state extraction type
` [PATCH datacenter-manager v2 04/20] context: promote context to a dir-style module
` [PATCH datacenter-manager v2 05/20] pdm-config: remotes: rename trait methods to read/write/lock
` [PATCH datacenter-manager v2 06/20] pdm-config: subscriptions: "
` [PATCH datacenter-manager v2 07/20] remote iterator: pass remote config reader explicitly
` [PATCH datacenter-manager v2 08/20] context: introduce a ContextFactory to build application context
` [PATCH datacenter-manager v2 09/20] context: establish PdmApplication object
` [PATCH datacenter-manager v2 10/20] context: register PdmApplication in router
` [PATCH datacenter-manager v2 11/20] parallel fetcher: pass arguments to closure in a single type
` [PATCH datacenter-manager v2 12/20] parallel fetcher: support a custom client factory
` [PATCH datacenter-manager v2 13/20] api: sdn: use PdmApplication handle for accessing remotes
` [PATCH datacenter-manager v2 14/20] tests: add helpers for building API-handler-level integration tests
` [PATCH datacenter-manager v2 15/20] tests: add example tests for SDN API routes
` [PATCH datacenter-manager v2 16/20] api-cache: add wrapper type
` [PATCH datacenter-manager v2 17/20] context: provide api-cache on the app object
` [PATCH datacenter-manager v2 18/20] api: subscriptions: use PdmApplication instead of globals
` [PATCH datacenter-manager v2 19/20] pdm-config: subscriptions: drop unused accessor functions
` [PATCH datacenter-manager v2 20/20] tests: add example tests for remote subscription management
[PATCH pve-network] sdn: ipam: fix dual-stack per-MAC lookup in the PVE plugin
2026-08-24 13:42 UTC
[PATCH docs/manager 0/4] manager/docs: fix: #6211: ui: docs: add reference to vm options protection/IDX/SEV
2026-08-24 13:24 UTC (2+ messages)
` superseded: "
[PATCH datacenter-manager/proxmox 00/20] inject application context via API macro for easier integration testing
2026-08-24 13:13 UTC (14+ messages)
` [PATCH proxmox 01/20] router: introduce shared state
` [PATCH proxmox 03/20] api-macro: support shared state extraction type
` [PATCH datacenter-manager 06/20] pdm-config: subscriptions: rename trait methods to read/write/lock
` [PATCH datacenter-manager 11/20] parallel fetcher: pass arguments to closure in a single type
` superseded: [PATCH datacenter-manager/proxmox 00/20] inject application context via API macro for easier integration testing
[PATCH manager] fix #7896: ui: qemu: show effective machine version for Windows guests
2026-08-24 13:03 UTC (3+ messages)
` superseded: "
[PATCH manager v2] fix #7896: ui: qemu: show effective machine version for Windows guests
2026-08-24 13:01 UTC
[PATCH proxmox-backup 1/1] openid auth: improve error logging
2026-08-24 12:57 UTC
[PATCH docs/storage 0/2] docs: match smbdescription at pve-docs and pve-storage
2026-08-24 12:34 UTC (5+ messages)
` [PATCH storage 1/1] cifs: match smbversion description with docs
` [PATCH docs 1/1] docs: cifs: match smbversion docs with pve-storage
` applied: "
[PATCH proxmox-backup 0/2] fix #6990: server: drop verify state on push & pull job
2026-08-24 12:31 UTC (2+ messages)
` superseded: "
[PATCH manager] fix #6735: api: pci: extend mdevscan persmissions for mappings
2026-08-24 11:26 UTC
[PATCH datacenter-manager 1/1] fix #7135: openid auth: improve error logging
2026-08-24 11:01 UTC (4+ messages)
` applied: "
[RFC] add max-depth to the datastore snapshots API endpoint
2026-08-24 10:08 UTC (3+ messages)
[PATCH-SERIES cluster 00/12] addressing large ipc message responses
2026-08-24 8:56 UTC (13+ messages)
` [PATCH cluster 01/12] buildsys: include pmxcfs tidy target in top-level tidy target
` [PATCH cluster 02/12] run make tidy
` [PATCH cluster 03/12] pmxcfs: server: simplify non-negative ipc message result responses
` [PATCH cluster 04/12] pmxcfs: server: simplify ipc message response logic
` [PATCH cluster 05/12] pmxcfs: server: report responses exceeding the maximum message size
` [PATCH cluster 06/12] pmxcfs: server: remove unnecessary local variable alignment attributes
` [PATCH cluster 07/12] pmxcfs: server: move message handling to separate function
` [PATCH cluster 08/12] pmxcfs: server: move message response sending "
` [PATCH cluster 09/12] pmxcfs: server: simplify message response size calculation
` [PATCH cluster 10/12] ipcc: move the data pointer initialization up
` [PATCH cluster 11/12] pmxcfs: server: do not forward qb_ipc_request_header to s1_msg_handle_request
` [RFC PATCH cluster 12/12] allow large ipc responses by sending the response message in chunks
[PATCH proxmox-yew-comp] fix #7963: acme: filter ACME DNS Plugins by their human-readable name
2026-08-24 8:12 UTC (2+ messages)
` applied: "
[PATCH yew-comp] fix #7959: acme: use correct validation-delay maximum
2026-08-24 7:55 UTC (3+ messages)
` superseded: "
[PATCH yew-comp v2] fix #7959: acme: use correct validation-delay maximum
2026-08-24 7:53 UTC
[PATCH docs/manager/network/perl-rs v4 0/6] sdn: enable force_forwarding for ipv6 forwarding
2026-08-24 7:33 UTC (6+ messages)
` [PATCH network v4 1/6] sdn: evpn: enable force_forwarding for ipv6 forwarding to subnets
` [PATCH perl-rs v4 3/6] fabrics: openfabric: enable force_forwarding for ipv6 transit traffic
[PATCH v4 pve-qemu qemu-server 0/3] bypass host page cache for restore on zvol
2026-08-23 13:04 UTC (4+ messages)
` [PATCH v4 qemu-server 2/3] pbs-restore: set 'no-cache' on block devices backed by zfspool
[RFC] qemu-server: add opt-in support for QEMU seccomp sandbox
2026-08-22 14:30 UTC
[PATCH v4 i18n 0/1] add pgettext() and npgettext() support for context-aware translations
2026-08-22 13:22 UTC (4+ messages)
` [PATCH v4 i18n 1/1] "
[pve-devel] [RFC] qemu-server: add migration_type=insecure to remote-migrate
2026-08-22 12:48 UTC (2+ messages)
` [PATCH v3 qemu-server] remote migration: allow insecure TCP data plane
[RFC manager/network/proxmox{-ve-rs,-perl-rs} 00/15] SDN VRF support
2026-08-21 14:03 UTC (16+ messages)
` [PATCH proxmox-ve-rs 01/15] frr: add VRF-aware OSPF rendering
` [PATCH proxmox-ve-rs 02/15] sdn: add zone references to OSPF and BGP fabrics
` [PATCH proxmox-ve-rs 03/15] sdn: generate fabric routing configuration in zone VRFs
` [PATCH proxmox-ve-rs 04/15] sdn: fix VRF route-map scoping and zone ID validation
` [PATCH proxmox-ve-rs 05/15] tests: fabrics: add test for fabrics in VRFs
` [PATCH proxmox-perl-rs 06/15] pve-rs: fabrics: assign network interfaces to configured VRFs
` [PATCH proxmox-perl-rs 07/15] pve-rs: fabrics: make per-fabric status queries VRF-aware
` [PATCH proxmox-perl-rs 08/15] pve-rs: fabrics: include VRF routes in aggregate status
` [PATCH pve-network 09/15] sdn: add optional VRFs for simple zones
` [PATCH pve-network 10/15] sdn: allow fabrics to use simple zone VRFs
` [PATCH pve-network 11/15] sdn: always generate EVPN "
` [PATCH pve-network 12/15] api: sdn: allow EVPN zones as fabric VRFs
` [PATCH pve-network 13/15] api: sdn: disallow BGP fabrics in EVPN zone VRFs
` [PATCH pve-manager 14/15] ui: sdn: add VRF zone selection for fabrics
` [PATCH pve-manager 15/15] ui: sdn: expose EVPN zones as fabric VRFs
[PATCH proxmox-backup 0/2] Fix Undefined Behavior in Tape Block Header Deallocation
2026-08-21 14:03 UTC (2+ messages)
` superseded: "
[PATCH proxmox{,-backup} v2 00/10] Fix Undefined Behavior in Tape Block Header Deallocation
2026-08-21 14:02 UTC (11+ messages)
` [PATCH proxmox v2 01/10] proxmox-alloc: introduce proxmox-alloc with `LayoutAwareBox<T>` type
` [PATCH proxmox v2 02/10] proxmox-alloc: document undefined behavior regarding custom allocs
` [PATCH proxmox-backup v2 03/10] tape: move tape block structs into separate file module
` [PATCH proxmox-backup v2 04/10] tape: rename `BlockHeader` and `BlockHeaderFlags`
` [PATCH proxmox-backup v2 05/10] tape: blocked_{reader,writer}: rename `buffer` to `tape_block`
` [PATCH proxmox-backup v2 06/10] tape: tape block: represent tape block header with its own struct
` [PATCH proxmox-backup v2 07/10] tape: tape block: make `payload` field private
` [PATCH proxmox-backup v2 08/10] tape: blocked_{reader,writer}: remove haphazard `unsafe` blocks
` [PATCH proxmox-backup v2 09/10] tape: tape block: fix undefined behavior on tape block deallocation
` [PATCH proxmox-backup v2 10/10] tape: sgutils2: fix undefined behavior in dealloc of buffer
[PATCH manager] fix #6113: ui: import: add pool selector
2026-08-21 13:53 UTC (2+ messages)
` applied: "
[PATCH proxmox{_login_manager,_dart_api_client}/pve_flutter_frontend 0/3] cleanup: enable avoid_print Linter rule
2026-08-21 13:07 UTC (4+ messages)
` [PATCH pve_flutter_frontend 1/1] cleanup: remove print statements
` [PATCH proxmox_login_manager "
` [PATCH proxmox_dart_api_client 1/1] cleanup: avoid "
[PATCH datacenter-manager v2 0/9] refactor and partially fix #7371
2026-08-21 12:51 UTC (2+ messages)
` superseded: "
[PATCH datacenter-manager v3 0/9] refactor and partially fix #7371
2026-08-21 12:30 UTC (10+ messages)
` [PATCH datacenter-manager v3 1/9] lib: api types: add new ResourceView type and move accessors there
` [PATCH datacenter-manager v3 2/9] lib: api types: resource: add 'node' helper to ResourceView
` [PATCH datacenter-manager v3 3/9] lib: api types: add guest specific getter "
` [PATCH datacenter-manager v3 4/9] ui: pve: factor out the pve-manager version extraction
` [PATCH datacenter-manager v3 5/9] ui: renderer: use ResourceView for rendering
` [PATCH datacenter-manager v3 6/9] ui: pve: tree: reuse `PveResource` for `PveTreeNode`
` [PATCH datacenter-manager v3 7/9] ui: pve: show ha maintenance mode for nodes
` [PATCH datacenter-manager v3 8/9] ui: pve: node selector: show maintenance badge with node name
` [PATCH datacenter-manager v3 9/9] ui: pve: node: show ha maintenance badge
[PATCH proxmox-backup v2 0/3] fix #6990: server: drop verify state on push & pull job
2026-08-21 11:18 UTC (4+ messages)
` [PATCH proxmox-backup v2 1/3] server: pull: run blocking file operations on the blocking pool
` [PATCH proxmox-backup v2 2/3] fix #6990: server: drop verify state on push job
` [PATCH proxmox-backup v2 3/3] fix #6990: server: drop verify state on non-decrypt pull job
bug #7864: pool-scoped VM create with tags still broken. Could someone pick up the patch?
2026-08-21 8:29 UTC
[RFC] Centralized management for standalone PBS file clients
2026-08-21 7:09 UTC (4+ messages)
Native Windows client
2026-08-21 7:01 UTC (2+ messages)
PVE and AD domain join
2026-08-20 13:02 UTC
[PATCH docs 1/1] qm: clarify when the iothreads options takes into effect
2026-08-20 15:18 UTC (2+ messages)
page: next (older) | prev (newer) | latest
- recent:[subjects (threaded)|topics (new)|topics (active)]
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.