From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from gate001.proxmox.com (gate001.proxmox.com [45.144.208.40]) by lore.proxmox.com (Postfix) with ESMTPS id 18DC71FF0B4 for ; Fri, 27 Nov 2026 11:39:54 +0100 (CET) Received: from gate001.proxmox.com (localhost.localdomain [127.0.0.1]) by gate001.proxmox.com (Proxmox) with ESMTP id 7AA902173F; Fri, 27 Nov 2026 11:39:07 +0100 (CET) DKIM-Filter: OpenDKIM Filter v2.10.3 smtp.infra.comaite.com 4557262C05 DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=comaite.com; s=377A38C6-3A8D-11E5-A0EC-E97757B27CB3; t=1795775317; bh=Om6G4yfCFNNdqX0ddXtJ1F6l6LLONeJfnn03XsJR3Nw=; h=From:To:Date:Message-ID:MIME-Version; b=CG1x4SVcy7/fpR9McDzQLCCHHYOErOc3tZifRnlKY3cAxrO9bP6PXaB4WDrJ0xvJ3 s5UAgwnec2tdwffsmFKxsEHjdKiqzuS66gCp+TWEsBBgALbIOEhj28wohQ/ZN4iKjH P/LqqyLi+2NskwkaisDSVIPge4JEVpVanca4ZYbRBCe1vHGJ8jGKC5SOn3JQML+YVL JE+Zyhu3gqrxZBtEXXg8NEMPGZRXgJCdQP9NV81/EIkB6OkrFTCgsItJfVsSLoLF0q yT8HsETz1uGiHRkv1ligMPO6zLGYsnjNW0umlU3H5wir/ugDVlaeLWL+OxAthmOyGn sRKQqDxQO4iVg== From: =?UTF-8?q?R=C3=A9mi=20PAETA?= To: pve-devel@lists.proxmox.com Subject: [RFC PATCH v2 network 04/15] sdn: ovn: configure the chassis on boot and on network reload Date: Fri, 27 Nov 2026 11:28:25 +0100 Message-ID: <20261127102836.313797-5-remi.paeta@comaite.com> X-Mailer: git-send-email 2.47.3 In-Reply-To: <20261127102836.313797-1-remi.paeta@comaite.com> References: <20261127102836.313797-1-remi.paeta@comaite.com> MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit X-SPAM-LEVEL: Spam detection results: 2 AWL -1.900 Adjusted score from AWL reputation of From: address DKIM_SIGNED 0.1 Message has a DKIM or DK signature, not necessarily valid DKIM_VALID -0.1 Message has at least one valid DKIM or DK signature DKIM_VALID_AU -0.1 Message has a valid DKIM or DK signature from author's domain DKIM_VALID_EF -0.1 Message has a valid DKIM or DK signature from envelope-from domain DMARC_PASS -0.1 DMARC pass policy KAM_SHORT 0.001 Use of a URL Shortener for very short URL SPF_HELO_NONE 0.001 SPF: HELO does not publish an SPF Record SPF_PASS -0.001 SPF: sender matches SPF record URIBL_DBL_SPAM 5 Contains a spam URL listed in the Spamhaus DBL blocklist [sdn.pm] Message-ID-Hash: D7RHPJKLERSDNGFQLDWEAF7KAPTVRJBU X-Message-ID-Hash: D7RHPJKLERSDNGFQLDWEAF7KAPTVRJBU X-MailFrom: remi.paeta@comaite.com X-Mailman-Rule-Misses: dmarc-mitigation; no-senders; approved; loop; banned-address; emergency; member-moderation; nonmember-moderation; administrivia; implicit-dest; max-recipients; max-size; news-moderation; no-subject; digests; suspicious-header X-Mailman-Version: 3.3.10 Precedence: list List-Id: Proxmox VE development discussion List-Help: List-Owner: List-Post: List-Subscribe: List-Unsubscribe: ovn-controller needs the southbound database, the encapsulation type and the local tunnel IP, which are stored in the external_ids of the local Open_vSwitch table. They are now set whenever the network configuration of a node gets generated, using the local IP of the route towards the southbound database as tunnel IP. A chassis attached by PVE gets detached again once the node is not part of any OVN zone anymore. A node can only be attached to a single OVN deployment. pvenetcommit.service removes the Open vSwitch database on every boot, which drops these settings. The new pve-sdn-ovn-chassis.service sets them again before the guests get started. The postinst needs the debhelper token for the unit to get enabled. ovn-controller needs a few seconds to connect to the southbound database, so wait for up to ten seconds before warning that it is not connected. The zone status also reports an ovn-controller that is not connected. ovs-vsctl gets --timeout and --no-wait, as ovn-controller reads these settings from the Open vSwitch database itself: if ovs-vswitchd does not run, waiting for it would block the boot service, and with it the start of all guests, and the node reload. The unit gets a start timeout and is also ordered before pve-ha-lrm, which starts HA guests. Signed-off-by: Rémi PAETA --- Changes since v1: - ovs-vsctl gets --timeout and --no-wait: a stopped ovs-vswitchd blocked the boot service, and with it all guest starts - the unit gets a start timeout and is ordered before pve-ha-lrm too debian/libpve-network-perl.install | 1 + debian/libpve-network-perl.postinst | 2 + src/PVE/Network/SDN.pm | 19 +++ src/PVE/Network/SDN/Ovn.pm | 183 +++++++++++++++++++++++ src/PVE/Network/SDN/Zones/OvnPlugin.pm | 2 + src/services/Makefile | 1 + src/services/pve-sdn-ovn-chassis.service | 18 +++ src/test/run_test_ovn.pl | 149 ++++++++++++++++++ 8 files changed, 375 insertions(+) create mode 100644 src/services/pve-sdn-ovn-chassis.service diff --git a/debian/libpve-network-perl.install b/debian/libpve-network-perl.install index 4e63c1f..ad5fc2d 100644 --- a/debian/libpve-network-perl.install +++ b/debian/libpve-network-perl.install @@ -1,2 +1,3 @@ lib/systemd/system/dnsmasq@.service.d/00-dnsmasq-after-networking.conf /usr/lib/systemd/system/dnsmasq@.service.d/ +lib/systemd/system/pve-sdn-ovn-chassis.service /usr/lib/systemd/system/ usr/share/perl5/PVE/Network diff --git a/debian/libpve-network-perl.postinst b/debian/libpve-network-perl.postinst index 99faedf..360863e 100644 --- a/debian/libpve-network-perl.postinst +++ b/debian/libpve-network-perl.postinst @@ -32,4 +32,6 @@ case "$1" in ;; esac +#DEBHELPER# + exit 0 diff --git a/src/PVE/Network/SDN.pm b/src/PVE/Network/SDN.pm index 28cf8e6..e83f968 100644 --- a/src/PVE/Network/SDN.pm +++ b/src/PVE/Network/SDN.pm @@ -554,12 +554,18 @@ sub write_raw_etc_network_config { Generates the network configuration for all SDN plugins and writes it to the SDN interfaces files (/etc/network/interfaces.d/sdn). +Also configures the local OVN chassis, as this is called on every node when the +SDN configuration gets applied. + =cut sub generate_etc_network_config { my $running_cfg = PVE::Network::SDN::running_config(); my $raw_config = PVE::Network::SDN::generate_raw_etc_network_config($running_cfg); PVE::Network::SDN::write_raw_etc_network_config($raw_config); + + eval { PVE::Network::SDN::Ovn::configure_chassis($running_cfg) }; + log_warn("failed to configure the OVN chassis - $@") if $@; } =head3 generate_frr_raw_config(\%running_config, \%fabric_config) @@ -679,6 +685,19 @@ sub sync_ovn_northbound { PVE::Network::SDN::Ovn::sync_northbound($previous_running_config, $running_config); } +=head3 generate_ovn_chassis_config() + +Configures the local ovn-controller according to the OVN zones of this node. +Called on boot by pve-sdn-ovn-chassis.service, as the Open vSwitch database +gets recreated on every boot. + +=cut + +sub generate_ovn_chassis_config { + my $running_config = PVE::Network::SDN::running_config(); + PVE::Network::SDN::Ovn::configure_chassis($running_config); +} + sub encode_value { my ($type, $key, $value) = @_; diff --git a/src/PVE/Network/SDN/Ovn.pm b/src/PVE/Network/SDN/Ovn.pm index 6e71be3..51f3730 100644 --- a/src/PVE/Network/SDN/Ovn.pm +++ b/src/PVE/Network/SDN/Ovn.pm @@ -5,15 +5,22 @@ use v5.36; use JSON; use PVE::Cluster; +use PVE::INotify; use PVE::Network; +use PVE::RESTEnvironment qw(log_warn); use PVE::Tools qw(run_command); +use PVE::Network::SDN::Zones::Plugin; + our $NBCTL = '/usr/bin/ovn-nbctl'; our $VSCTL = '/usr/bin/ovs-vsctl'; # ovn-controller reads the Open vSwitch database itself, so ovs-vsctl does not wait # for ovs-vswitchd, which may not run (boot, crash) my @VSCTL_OPTS = ('--timeout=10', '--no-wait'); +our $APPCTL = '/usr/bin/ovn-appctl'; my $NBCTL_TIMEOUT = 10; +# seconds to wait for ovn-controller to connect to the southbound database +our $CONNECT_TIMEOUT = 10; our $INTEGRATION_BRIDGE = 'br-int'; @@ -25,6 +32,9 @@ my $EXT_ZONE = 'pve-sdn-zone'; my $EXT_VNET = 'pve-sdn-vnet'; my $EXT_VMID = 'pve-sdn-vmid'; +# chassis settings written to the local Open_vSwitch table +my @CHASSIS_KEYS = ('ovn-remote', 'ovn-encap-type', 'ovn-encap-ip', $EXT_CONTROLLER); + =head3 ovn_controllers(\%running_cfg) Returns a hash of all controllers of type C in C<\%running_cfg>, keyed by @@ -478,4 +488,177 @@ sub plug_port { run_command([$VSCTL, @VSCTL_OPTS, 'set', 'Interface', $port, "external_ids:iface-id=$iface"]); } +=head3 local_controllers(\%running_cfg, $nodename) + +Returns the OVN controllers used by the zones that are active on C<$nodename>. + +=cut + +sub local_controllers { + my ($running_cfg, $nodename) = @_; + + my $controllers = ovn_controllers($running_cfg); + my $zones = $running_cfg->{zones}->{ids} // {}; + + my $local = {}; + for my $zone (values %$zones) { + next if $zone->{type} ne 'ovn'; + next if $zone->{nodes} && !$zone->{nodes}->{$nodename}; + + my $controllerid = $zone->{controller}; + $local->{$controllerid} = $controllers->{$controllerid} + if $controllerid && $controllers->{$controllerid}; + } + + return $local; +} + +=head3 parse_remote_ip($remotes) + +Returns the IP address of the first entry of an OVN database connection string +such as C. + +=cut + +sub parse_remote_ip { + my ($remotes) = @_; + + my ($first) = split(/,/, $remotes); + return $1 if $first =~ m/^[a-z]+:\[([^\]]+)\]:\d+$/; + return $1 if $first =~ m/^[a-z]+:([^:]+):\d+$/; + + die "unable to parse OVN database connection '$first'\n"; +} + +=head3 chassis_settings($controllerid, $controller, $encap_ip) + +Returns the external_ids to set in the local Open_vSwitch table so that +ovn-controller joins the OVN deployment of C<$controller>. + +=cut + +sub chassis_settings { + my ($controllerid, $controller, $encap_ip) = @_; + + return { + 'ovn-remote' => $controller->{'sb-connection'}, + 'ovn-encap-type' => $controller->{'encap-type'} // 'geneve', + 'ovn-encap-ip' => $encap_ip, + $EXT_CONTROLLER => $controllerid, + }; +} + +=head3 configure_chassis(\%running_cfg) + +Configures the local ovn-controller for the OVN controller used by the zones of +this node, or detaches it if no zone uses OVN anymore. Called on every node when +the SDN configuration gets applied. + +=cut + +sub configure_chassis { + my ($running_cfg) = @_; + + my $nodename = PVE::INotify::nodename(); + my $controllers = local_controllers($running_cfg, $nodename); + my @ids = sort keys %$controllers; + + if (!-x $VSCTL) { + die "Open vSwitch is not installed, but node '$nodename' is part of an OVN zone\n" + if @ids; + return; + } + + if (@ids > 1) { + die "node '$nodename' is part of zones using different OVN controllers (@ids), but a" + . " node can only be attached to one OVN deployment\n"; + } + + if (!@ids) { + # only detach a chassis that was attached by us + my $attached = ''; + eval { + run_command( + [ + $VSCTL, + @VSCTL_OPTS, + '--if-exists', + 'get', + 'Open_vSwitch', + '.', + "external_ids:$EXT_CONTROLLER", + ], + outfunc => sub { $attached .= $_[0]; }, + ); + }; + if ($attached) { + run_command( + [$VSCTL, @VSCTL_OPTS, 'remove', 'Open_vSwitch', '.', 'external_ids', @CHASSIS_KEYS], + ); + } + return; + } + + my $id = $ids[0]; + my $controller = $controllers->{$id}; + + my $remote_ip = parse_remote_ip($controller->{'sb-connection'}); + my ($encap_ip) = PVE::Network::SDN::Zones::Plugin::get_local_route_ip($remote_ip); + die "unable to find the local IP to reach the OVN southbound database at $remote_ip\n" + if !$encap_ip; + + my $settings = chassis_settings($id, $controller, $encap_ip); + run_command([ + $VSCTL, + @VSCTL_OPTS, + 'set', + 'Open_vSwitch', + '.', + map { "external_ids:$_=$settings->{$_}" } sort keys %$settings, + ]); + + if (!wait_controller_connected($CONNECT_TIMEOUT)) { + log_warn( + "ovn-controller is not connected to the OVN southbound database: running guests keep" + . " their connectivity, but new guest interfaces and OVN configuration changes are" + . " only applied once it is", + ); + } +} + +# ovn-controller needs a few seconds to connect, especially after a restart +sub wait_controller_connected { + my ($timeout) = @_; + + for (my $i = 0; $i < $timeout; $i++) { + return 1 if controller_connected(); + sleep(1); + } + + return controller_connected(); +} + +=head3 controller_connected() + +Returns whether the local ovn-controller is connected to the southbound +database. + +=cut + +sub controller_connected { + return 0 if !-x $APPCTL; + + my $status = ''; + eval { + run_command( + [$APPCTL, '-t', 'ovn-controller', 'connection-status'], + outfunc => sub { $status .= $_[0]; }, + errfunc => sub { }, + timeout => 5, + ); + }; + + return $status eq 'connected'; +} + 1; diff --git a/src/PVE/Network/SDN/Zones/OvnPlugin.pm b/src/PVE/Network/SDN/Zones/OvnPlugin.pm index 26557e7..fc15e20 100644 --- a/src/PVE/Network/SDN/Zones/OvnPlugin.pm +++ b/src/PVE/Network/SDN/Zones/OvnPlugin.pm @@ -66,6 +66,8 @@ sub status { if (!-d "/sys/class/net/$PVE::Network::SDN::Ovn::INTEGRATION_BRIDGE") { push @$err_msg, "missing $PVE::Network::SDN::Ovn::INTEGRATION_BRIDGE"; + } elsif (!PVE::Network::SDN::Ovn::controller_connected()) { + push @$err_msg, "ovn-controller not connected to the southbound database"; } return $err_msg; diff --git a/src/services/Makefile b/src/services/Makefile index 818c106..b6cd56d 100644 --- a/src/services/Makefile +++ b/src/services/Makefile @@ -8,6 +8,7 @@ install: install -d $(SERVICEDIR) install -d $(SERVICEDIR)/dnsmasq@.service.d install -t $(SERVICEDIR)/dnsmasq@.service.d -m 0644 00-dnsmasq-after-networking.conf + install -t $(SERVICEDIR) -m 0644 pve-sdn-ovn-chassis.service .PHONY: clean clean: diff --git a/src/services/pve-sdn-ovn-chassis.service b/src/services/pve-sdn-ovn-chassis.service new file mode 100644 index 0000000..8f05d4b --- /dev/null +++ b/src/services/pve-sdn-ovn-chassis.service @@ -0,0 +1,18 @@ +# The Open vSwitch database gets recreated on every boot (see +# pvenetcommit.service), so the OVN chassis settings need to be set again +# before the guests get started. +[Unit] +Description=Configure the OVN chassis of the Proxmox VE SDN +Wants=pve-cluster.service +After=pve-cluster.service ovs-vswitchd.service networking.service +Before=pve-guests.service pve-ha-lrm.service + +[Service] +Type=oneshot +# guests are only started once this unit is done +TimeoutStartSec=180 +ExecStart=/usr/bin/perl -e 'use PVE::Network::SDN; PVE::Network::SDN::generate_ovn_chassis_config()' +RemainAfterExit=yes + +[Install] +WantedBy=multi-user.target diff --git a/src/test/run_test_ovn.pl b/src/test/run_test_ovn.pl index b453c75..45afe59 100755 --- a/src/test/run_test_ovn.pl +++ b/src/test/run_test_ovn.pl @@ -361,6 +361,155 @@ eval { }; like($@, qr/isolate-ports is not supported/, 'vnet_update_hook: isolate-ports refused'); +# chassis + +is( + PVE::Network::SDN::Ovn::parse_remote_ip('tcp:10.0.0.1:6642,tcp:10.0.0.2:6642'), + '10.0.0.1', + 'parse_remote_ip: ipv4', +); +is( + PVE::Network::SDN::Ovn::parse_remote_ip('tcp:[fd00::1]:6642'), + 'fd00::1', + 'parse_remote_ip: ipv6', +); + +is_deeply( + [sort keys PVE::Network::SDN::Ovn::local_controllers($running_cfg, 'node1')->%*], + ['ovnctl'], + 'local_controllers: zone restricted to other nodes is ignored', +); + +is_deeply( + PVE::Network::SDN::Ovn::chassis_settings('ovnctl', $controller, '192.168.0.10'), + { + 'ovn-remote' => $controller->{'sb-connection'}, + 'ovn-encap-type' => 'geneve', + 'ovn-encap-ip' => '192.168.0.10', + 'pve-sdn-controller' => 'ovnctl', + }, + 'chassis_settings', +); + +my $vsctl_calls = []; +my $attached = ''; +$PVE::Network::SDN::Ovn::VSCTL = '/bin/true'; +$ovn_module->mock( + run_command => sub { + my ($cmd, %param) = @_; + if (grep { $_ eq 'get' } @$cmd) { + $param{outfunc}->($attached) if $attached; + return; + } + push @$vsctl_calls, [$cmd->@[1 .. $#$cmd]]; + }, + controller_connected => sub { return 1 }, +); +my $inotify_module = Test::MockModule->new('PVE::INotify'); +$inotify_module->mock(nodename => sub { return 'node1' }); +my $zones_plugin_module = Test::MockModule->new('PVE::Network::SDN::Zones::Plugin'); +$zones_plugin_module->mock(get_local_route_ip => sub { return ('192.168.0.10', 'vmbr0') }); + +PVE::Network::SDN::Ovn::configure_chassis($running_cfg); +is_deeply( + $vsctl_calls, + [[ + '--timeout=10', + '--no-wait', + 'set', + 'Open_vSwitch', + '.', + 'external_ids:ovn-encap-ip=192.168.0.10', + 'external_ids:ovn-encap-type=geneve', + "external_ids:ovn-remote=$controller->{'sb-connection'}", + 'external_ids:pve-sdn-controller=ovnctl', + ]], + 'configure_chassis: attach chassis', +); + +$vsctl_calls = []; +PVE::Network::SDN::Ovn::configure_chassis({}); +is_deeply($vsctl_calls, [], 'configure_chassis: leave chassis not attached by PVE alone'); + +$attached = '"ovnctl"'; +PVE::Network::SDN::Ovn::configure_chassis({}); +is_deeply( + $vsctl_calls, + [[ + '--timeout=10', + '--no-wait', + 'remove', + 'Open_vSwitch', + '.', + 'external_ids', + 'ovn-remote', + 'ovn-encap-type', + 'ovn-encap-ip', + 'pve-sdn-controller', + ]], + 'configure_chassis: detach chassis', +); + +my $two_controllers = { + controllers => { ids => { a => $controller, b => $controller } }, + zones => { + ids => { + za => { type => 'ovn', controller => 'a' }, + zb => { type => 'ovn', controller => 'b' }, + }, + }, +}; +eval { PVE::Network::SDN::Ovn::configure_chassis($two_controllers) }; +like( + $@, + qr/can only be attached to one OVN deployment/, + 'configure_chassis: one deployment per node', +); + +# chassis configured when the SDN configuration gets applied + +my $sdn_module = Test::MockModule->new('PVE::Network::SDN'); +my $written; +$sdn_module->mock( + running_config => sub { return $running_cfg }, + generate_raw_etc_network_config => sub { return "raw" }, + write_raw_etc_network_config => sub { $written = $_[0] }, +); +my $chassis_cfg; +$ovn_module->mock(configure_chassis => sub { $chassis_cfg = $_[0] }); +PVE::Network::SDN::generate_etc_network_config(); +is($written, 'raw', 'generate_etc_network_config: network config written'); +is($chassis_cfg, $running_cfg, 'generate_etc_network_config: chassis configured'); + +$written = undef; +$ovn_module->mock(configure_chassis => sub { die "ovs down\n" }); +my @warnings; +$sdn_module->mock(log_warn => sub { push @warnings, $_[0] }); +eval { PVE::Network::SDN::generate_etc_network_config() }; +is($@, '', 'generate_etc_network_config: chassis failure does not abort'); +is($written, 'raw', 'generate_etc_network_config: network config written despite chassis failure'); +like( + join('', @warnings), + qr/failed to configure the OVN chassis - ovs down/, + 'generate_etc_network_config: chassis failure is logged', +); +$ovn_module->unmock('configure_chassis'); +$sdn_module->unmock_all(); + +# ovn-controller connection + +my $connection_checks = 0; +my $connected_after = 2; +$ovn_module->mock( + controller_connected => + sub { $connection_checks++; return $connection_checks >= $connected_after }, +); +ok(PVE::Network::SDN::Ovn::wait_controller_connected(10), 'wait_controller_connected: connects'); +is($connection_checks, 2, 'wait_controller_connected: waits until connected'); +($connection_checks, $connected_after) = (0, 100); +ok(!PVE::Network::SDN::Ovn::wait_controller_connected(1), 'wait_controller_connected: timeout'); +$ovn_module->mock(controller_connected => sub { return 1 }); + # controller schema ok( -- 2.47.3