Date: Mon, 16 Nov 2026 17:30:25 +0100	[thread overview]
Message-ID: <20261116163138.343821-1-d.csapak@proxmox.com> (raw)

This splits the disks and nics of the qemu hardware view into their own
grids, where each option gets its own column (including pending
changes), instead of showing the raw config string in one big list.

New in this version is that the series does the same for containers:
the volumes (rootfs, mount points, unused disks) get their own grid in
the resource view, and the existing network view is converted to show
pending changes and then moved into the resource view too, so there is
no separate 'Network' panel for containers anymore.

For the container network view I tried to keep the existing behavior
and code where possible (it still shows the name and addresses from
inside the container), so that patch is hopefully easy to compare with
what we have now. It differs a bit from the qemu net grid in that it
keeps its own toolbar instead of the surrounding view handling the
buttons, since it had that before and it does not need anything from
the resource view.

I tried to keep most commits small so it's easier to see what the actual
changes are.

NOTE: I took special care for the button enablement logic, but having a
close look at that during review would make a lot of sense. That goes
for the new container patches as well.

Not addressed from the v4 feedback are the horizontal scrollbar topics
(overlapping the last row, toolbar not scrolling with the grid), since
those are not specific to this series.

changes from v4:
* rebased on master
* new patches to do the same for containers (volumes and nics)
* re-added the parser patch for '-' in key names (reverted on master)
* pending grid: don't save sorters in the state
* pending grid: handle nested columns
* pending grid: mark the id of entries with pending changes
* pending grid: don't break on properties the parser does not know
* config remove button: make the waitMsgTarget configurable
* fix the remove button and the storage content selection mid-series
* disk grid: fix 'Secure Boot', 'Replicate' and 'Async I/O' columns
* net grid: fix the 'Disconnected' column
* make the hardware view scrollable
* fix sorting of the disk and net grids (e.g. unused disks)
* update the buttons when the selected entry changes on a reload
* fix the edit button in the general grid and for nics
* fix the 'Enroll Updated Certificates' button
* show 'Attach' for unused disks and don't allow reassigning tpmstate

changes from v3:
* rebased on master:
  - dropped the parser patch (something similar was already applied)
  - while moving to a container, the selection logic when coming from
    a storage content panel had to be adapted.

changes from v2:
* reorganized code/commits for the most part, so it doesn't make much
  sense to compare it to the previous version

changes from v1:
* refactor some regexes/checks
* fix some bugs I encountered during testing again

Dominik Csapak (18):
  ui: utils: factor out 'media=cdrom' check
  ui: parser: qemu drive: allow '-' in key name
  ui: factor out the guest key nic regex check
  ui: add pending grid
  ui: revert button: add parentXType and reloadCallback
  ui: button: add config remove button
  ui: qemu: hardware: wrap in container
  ui: qemu: introduce hardware disk grid
  ui: qemu: introduce hardware net grid
  ui: qemu: hardware view: separate disks into own grid
  ui: qemu: hardware view: separate nics into own grid
  ui: qemu: hardware view: inline edit/remove/revert button in general
    grid
  ui: qemu: hardware view: inline 'add efi' menuitem
  ui: utils: factor out volume size renderer
  ui: lxc: network view: convert to pending grid
  ui: lxc: introduce resource volume grid
  ui: lxc: resources: separate volumes into own grid
  ui: lxc: resources: integrate network view

 www/manager6/Makefile                  |   5 +
 www/manager6/Parser.js                 |   2 +-
 www/manager6/Utils.js                  |  38 +-
 www/manager6/button/ConfigRemove.js    |  61 ++
 www/manager6/button/Revert.js          |   8 +-
 www/manager6/grid/PendingGrid.js       | 166 +++++
 www/manager6/lxc/Config.js             |   6 -
 www/manager6/lxc/Network.js            | 183 +++--
 www/manager6/lxc/ResourceVolumeGrid.js |  96 +++
 www/manager6/lxc/Resources.js          | 582 ++++++++-------
 www/manager6/qemu/BootOrderEdit.js     |  12 +-
 www/manager6/qemu/CreateWizard.js      |   4 +-
 www/manager6/qemu/HardwareDiskGrid.js  | 203 ++++++
 www/manager6/qemu/HardwareNetGrid.js   |  81 +++
 www/manager6/qemu/HardwareView.js      | 968 +++++++++++++++----------
 www/manager6/window/GuestImport.js     |   2 +-
 16 files changed, 1691 insertions(+), 726 deletions(-)
 create mode 100644 www/manager6/button/ConfigRemove.js
 create mode 100644 www/manager6/grid/PendingGrid.js
 create mode 100644 www/manager6/lxc/ResourceVolumeGrid.js
 create mode 100644 www/manager6/qemu/HardwareDiskGrid.js
 create mode 100644 www/manager6/qemu/HardwareNetGrid.js

-- 
2.47.3





             reply	other threads:[~2026-11-16 16:31 UTC|newest]

Thread overview: 20+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-11-16 16:30 Dominik Csapak [this message]
2026-11-16 16:30 ` [PATCH pve-manager v5 01/18] ui: utils: factor out 'media=cdrom' check Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 02/18] ui: parser: qemu drive: allow '-' in key name Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 03/18] ui: factor out the guest key nic regex check Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 04/18] ui: add pending grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 05/18] ui: revert button: add parentXType and reloadCallback Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 06/18] ui: button: add config remove button Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 07/18] ui: qemu: hardware: wrap in container Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 08/18] ui: qemu: introduce hardware disk grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 09/18] ui: qemu: introduce hardware net grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 10/18] ui: qemu: hardware view: separate disks into own grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 11/18] ui: qemu: hardware view: separate nics " Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 12/18] ui: qemu: hardware view: inline edit/remove/revert button in general grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 13/18] ui: qemu: hardware view: inline 'add efi' menuitem Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 14/18] ui: utils: factor out volume size renderer Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 15/18] ui: lxc: network view: convert to pending grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 16/18] ui: lxc: introduce resource volume grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 17/18] ui: lxc: resources: separate volumes into own grid Dominik Csapak
2026-11-16 16:30 ` [PATCH pve-manager v5 18/18] ui: lxc: resources: integrate network view Dominik Csapak
2026-11-19 10:01 ` superseded: [PATCH pve-manager v5 00/18] ui: split out disks and nics into grids Dominik Csapak

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20261116163138.343821-1-d.csapak@proxmox.com \
    --to=d.csapak@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal