all lists on lists.proxmox.com
 help / color / mirror / Atom feed
From: Michael Ryom <Michael@RyomHerold.dk>
To: pve-devel@lists.proxmox.com
Cc: Michael Ryom <Michael@RyomHerold.dk>
Subject: [PATCH ha-manager 2/7] env: dynamic service stats: use host-side memory footprint of guests
Date: Sun, 20 Sep 2026 18:22:09 +0200	[thread overview]
Message-ID: <20260920162220.574802-3-Michael@RyomHerold.dk> (raw)
In-Reply-To: <20260920162220.574802-1-Michael@RyomHerold.dk>

The dynamic service stats used the 'mem' RRD column of the guests, which
is the guest-reported memory usage (total_mem - free_mem) whenever the
balloon driver is active, and can be considerably lower than the actual
host-side footprint of the guest process (QEMU overhead, page cache
still mapped, etc.). The node stats, on the other hand, always contain
the full host view.

The scheduler simulates a migration by subtracting exactly the
service's stats from the source node and adding them to the target
node. With the guest-reported value, the predicted post-migration state
is systematically off by the difference between guest-reported and
host-side usage (over 1 GiB for a mid-size VM). This bias is of the
same order of magnitude as the trigger condition of the automatic load
balancer on a two-node cluster with a single dominant resource, and
contributes to a resource being moved back and forth.

Use the 'memhost' column (host-side cgroup usage, without KSM) instead
and fall back to 'mem' if it is unset: containers do not broadcast
'memhost', because their 'mem' already is the host-side cgroup value.

Signed-off-by: Michael Ryom <Michael@RyomHerold.dk>
---
 src/PVE/HA/Env/PVE2.pm | 14 +++++++++++++-
 1 file changed, 13 insertions(+), 1 deletion(-)

diff --git a/src/PVE/HA/Env/PVE2.pm b/src/PVE/HA/Env/PVE2.pm
index 782d19d..8c2b03d 100644
--- a/src/PVE/HA/Env/PVE2.pm
+++ b/src/PVE/HA/Env/PVE2.pm
@@ -46,6 +46,7 @@ use constant {
     RRD_VM_INDEX_CPU => 6,
     RRD_VM_INDEX_MAXMEM => 7,
     RRD_VM_INDEX_MEM => 8,
+    RRD_VM_INDEX_MEMHOST => 15,
 };
 
 # rrd entry indices for PVE nodes
@@ -598,11 +599,22 @@ sub get_dynamic_service_stats {
         # NOTE the guests' broadcasted vmstatus() caps maxcpu at the node's maxcpu
         my $maxcpu = ($rrdentry->[RRD_VM_INDEX_MAXCPU] || 0.0) + 0.0;
 
+        # prefer the host-side memory footprint over 'mem', which is the
+        # guest-reported usage (total_mem - free_mem) when the balloon driver
+        # is active and can be considerably lower than what running the guest
+        # actually consumes on the node; the node stats contain the full host
+        # view, so mixing in the guest view makes the scheduler's prediction
+        # of the post-migration state systematically off
+        #
+        # 'memhost' is only broadcasted for VMs, for CTs 'mem' already is the
+        # host-side (cgroup) usage
+        my $mem = int($rrdentry->[RRD_VM_INDEX_MEMHOST] || $rrdentry->[RRD_VM_INDEX_MEM] || 0);
+
         $stats->{$sid}->{usage} = {
             maxcpu => $maxcpu,
             cpu => (($rrdentry->[RRD_VM_INDEX_CPU] || 0.0) + 0.0) * $maxcpu,
             maxmem => int($rrdentry->[RRD_VM_INDEX_MAXMEM] || 0),
-            mem => int($rrdentry->[RRD_VM_INDEX_MEM] || 0),
+            mem => $mem,
         };
     }
 
-- 
2.47.3




  parent reply	other threads:[~2026-09-20 16:57 UTC|newest]

Thread overview: 9+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-09-20 16:22 [PATCH ha-manager 0/7] auto rebalance: fix failure retry loop, oscillation and idle-cluster churn Michael Ryom
2026-09-20 16:22 ` [PATCH ha-manager 1/7] fix #8059: manager: auto rebalance: back off failed motions and add per-resource cooldown Michael Ryom
2026-09-20 16:22 ` Michael Ryom [this message]
2026-09-21  9:18   ` [PATCH ha-manager 2/7] env: dynamic service stats: use host-side memory footprint of guests Dominik Rusovac
2026-09-20 16:22 ` [PATCH ha-manager 3/7] manager: auto rebalance: require a minimum absolute imbalance improvement Michael Ryom
2026-09-20 16:22 ` [PATCH ha-manager 4/7] sim: hardware: report actual running state in cluster service stats Michael Ryom
2026-09-20 16:22 ` [PATCH ha-manager 5/7] sim: hardware: allow setting a base load for nodes Michael Ryom
2026-09-20 16:22 ` [PATCH ha-manager 6/7] usage: dynamic: smooth the unaccounted node load Michael Ryom
2026-09-20 16:22 ` [PATCH ha-manager 7/7] manager: auto rebalance: only balance under actual node resource pressure Michael Ryom

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20260920162220.574802-3-Michael@RyomHerold.dk \
    --to=michael@ryomherold.dk \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal