Without that bridge, scsi14 and higher can't be hotplugged with lsi scsi
controllers (when the vm wasn't already started with such a disk), so
add it by default with the next machine version.

Add a test with a forced qemu version 11.1.

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
---
 src/PVE/QemuServer.pm                         |  2 +-
 src/PVE/QemuServer/PCI.pm                     |  4 +--
 src/test/cfg2cmd/linux-bridges-qemu-11.1.conf | 14 ++++++++
 .../cfg2cmd/linux-bridges-qemu-11.1.conf.cmd  | 36 +++++++++++++++++++
 4 files changed, 53 insertions(+), 3 deletions(-)
 create mode 100644 src/test/cfg2cmd/linux-bridges-qemu-11.1.conf
 create mode 100644 src/test/cfg2cmd/linux-bridges-qemu-11.1.conf.cmd

diff --git a/src/PVE/QemuServer.pm b/src/PVE/QemuServer.pm
index a5737f59..0294a0b3 100644
--- a/src/PVE/QemuServer.pm
+++ b/src/PVE/QemuServer.pm
@@ -3289,7 +3289,7 @@ sub config_to_command {
     }
 
     my $max_scsihw = PVE::QemuServer::DriveDevice::get_max_scsihw_index($conf);
-    if (my $bridges = get_pci_bridges($conf, $arch, $q35, $max_scsihw)) {
+    if (my $bridges = get_pci_bridges($conf, $arch, $q35, $max_scsihw, $version_guard)) {
         push @$devices, $bridges->@*;
     }
 
diff --git a/src/PVE/QemuServer/PCI.pm b/src/PVE/QemuServer/PCI.pm
index 2d10f2e1..d7dc6121 100644
--- a/src/PVE/QemuServer/PCI.pm
+++ b/src/PVE/QemuServer/PCI.pm
@@ -884,7 +884,7 @@ sub reserve_pci_usage {
 # Returns a list of bridge devices which are necessary for the remaining
 # devices.
 sub get_pci_bridges {
-    my ($conf, $arch, $q35, $max_scsihw) = @_;
+    my ($conf, $arch, $q35, $max_scsihw, $version_guard) = @_;
 
     my $bridges = {
         # 0 => 1, always present
@@ -896,7 +896,7 @@ sub get_pci_bridges {
 
     # some scsi controllers can only have 7 scsi disks per controller,
     # so scsi14 and upwards need scsihw2,3,4 which live on bridge 4
-    $bridges->{4} = 1 if $max_scsihw > 1;
+    $bridges->{4} = 1 if $max_scsihw > 1 || $version_guard->(11, 1);
 
     # use cheap legacy igd check instead of a full parse_hostpci
     my $legacy_igd = 0;
diff --git a/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf b/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf
new file mode 100644
index 00000000..fa9cc76b
--- /dev/null
+++ b/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf
@@ -0,0 +1,14 @@
+# TEST: Test that bridge pci.4 is added by default in qemu 11.1
+# QEMU_VERSION: 11.1.0
+bootdisk: scsi0
+cores: 3
+ide2: none,media=cdrom
+memory: 768
+name: simple
+net0: virtio=A2:C0:43:77:08:A0,bridge=vmbr0
+numa: 0
+ostype: l26
+scsi0: local:8006/vm-8006-disk-0.qcow2,discard=on,size=104858K
+smbios1: uuid=7b10d7af-b932-4c66-b2c3-3996152ec465
+sockets: 1
+vmgenid: c773c261-d800-4348-9f5d-167fadd53cf8
diff --git a/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf.cmd b/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf.cmd
new file mode 100644
index 00000000..2aebdffa
--- /dev/null
+++ b/src/test/cfg2cmd/linux-bridges-qemu-11.1.conf.cmd
@@ -0,0 +1,36 @@
+/usr/bin/kvm \
+  -id 8006 \
+  -name simple \
+  -no-shutdown \
+  -chardev 'socket,id=qmp,path=/var/run/qemu-server/8006.qmp,server=on,wait=off' \
+  -mon 'chardev=qmp,mode=control' \
+  -chardev 'socket,id=qmp-event,path=/var/run/qmeventd.sock,reconnect-ms=5000' \
+  -mon 'chardev=qmp-event,mode=control' \
+  -pidfile /var/run/qemu-server/8006.pid \
+  -daemonize \
+  -smbios 'type=1,uuid=7b10d7af-b932-4c66-b2c3-3996152ec465' \
+  -smp '3,sockets=1,cores=3,maxcpus=3' \
+  -nodefaults \
+  -boot 'menu=on,strict=on,reboot-timeout=1000,splash=/usr/share/qemu-server/bootsplash.jpg' \
+  -vnc 'unix:/var/run/qemu-server/8006.vnc,password=on' \
+  -cpu kvm64,enforce,+kvm_pv_eoi,+kvm_pv_unhalt,+lahf_lm,+sep \
+  -m 768 \
+  -object '{"id":"throttle-drive-scsi0","limits":{},"qom-type":"throttle-group"}' \
+  -global 'PIIX4_PM.disable_s3=1' \
+  -global 'PIIX4_PM.disable_s4=1' \
+  -device 'pci-bridge,id=pci.1,chassis_nr=1,bus=pci.0,addr=0x1e' \
+  -device 'pci-bridge,id=pci.2,chassis_nr=2,bus=pci.0,addr=0x1f' \
+  -device 'pci-bridge,id=pci.4,chassis_nr=4,bus=pci.1,addr=0x1c' \
+  -device 'vmgenid,guid=c773c261-d800-4348-9f5d-167fadd53cf8' \
+  -device 'piix3-usb-uhci,id=uhci,bus=pci.0,addr=0x1.0x2' \
+  -device 'usb-tablet,id=tablet,bus=uhci.0,port=1' \
+  -device 'VGA,id=vga,bus=pci.0,addr=0x2' \
+  -device 'virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x3,free-page-reporting=on' \
+  -iscsi 'initiator-name=iqn.1993-08.org.debian:01:aabbccddeeff' \
+  -device 'ide-cd,bus=ide.1,unit=0,id=ide2,bootindex=200' \
+  -device 'lsi,id=scsihw0,bus=pci.0,addr=0x5' \
+  -blockdev '{"detect-zeroes":"unmap","discard":"unmap","driver":"throttle","file":{"cache":{"direct":true,"no-flush":false},"detect-zeroes":"unmap","discard":"unmap","driver":"qcow2","file":{"aio":"io_uring","cache":{"direct":true,"no-flush":false},"detect-zeroes":"unmap","discard":"unmap","driver":"file","filename":"/var/lib/vz/images/8006/vm-8006-disk-0.qcow2","node-name":"ecd04be4259153b8293415fefa2a84c","read-only":false},"node-name":"fcd04be4259153b8293415fefa2a84c","read-only":false},"node-name":"drive-scsi0","read-only":false,"throttle-group":"throttle-drive-scsi0"}' \
+  -device 'scsi-hd,bus=scsihw0.0,scsi-id=0,drive=drive-scsi0,id=scsi0,device_id=drive-scsi0,bootindex=100,write-cache=on' \
+  -netdev 'type=tap,id=net0,ifname=tap8006i0,script=/usr/libexec/qemu-server/pve-bridge,downscript=/usr/libexec/qemu-server/pve-bridgedown,vhost=on' \
+  -device 'virtio-net-pci,mac=A2:C0:43:77:08:A0,netdev=net0,bus=pci.0,addr=0x12,id=net0,rx_queue_size=1024,tx_queue_size=256,bootindex=300,host_mtu=1500,host_tunnel=off' \
+  -machine 'hpet=off,type=pc+pve0'
-- 
2.47.3





      parent reply	other threads:[~2026-09-08 13:58 UTC|newest]

Thread overview: 9+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2026-09-08 13:52 [PATCH qemu-server v3 0/8] pci: bridges: cleanup and hotplug fix Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 1/8] tests: cfg2cmd: add test for ivshmem with q35 Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 2/8] tests: cfg2cmd: add q35 + win7 + hostpci test Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 3/8] code cleanup: pci: don't export print_pcie_root_port Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 4/8] code cleanup: hot-plug: simplify getting bridge for device Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 5/8] hotplug: don't try to hotplug bridges Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 6/8] cfg2cmd: reject guests with machine version below 5.0 Dominik Csapak
2026-09-08 13:52 ` [PATCH qemu-server v3 7/8] cfg2cmd: pci: add bridges to device list up front Dominik Csapak
2026-09-08 13:52 ` Dominik Csapak [this message]

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20260908135729.3869365-9-d.csapak@proxmox.com \
    --to=d.csapak@proxmox.com \
    --cc=pve-devel@lists.proxmox.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.
Service provided by Proxmox Server Solutions GmbH | Privacy | Legal